NVIDIA BlueField DPU Datacenter Vision

NVIDIA BlueField DPU Architecture Explained

Network Insight
Engineering Knowledge Series
SILICON OFFLOAD EDITION
AI Infrastructure / Accelerated Networking / Data Centres

NVIDIA BlueField DPU Architecture Explained

Engineering high-performance data centre infrastructure with dedicated data processing units, programmable networking, hardware-accelerated storage and isolated infrastructure security.

BlueField ConnectX Arm Processing DOCA RDMA PCIe Zero Trust AI Infrastructure
ACCELERATED SERVER ARCHITECTURE
Conceptual NVIDIA BlueField server architecture Host CPU and GPU communicate through PCIe with a BlueField DPU containing Arm cores, ConnectX networking and infrastructure acceleration capabilities. The DPU connects to external networking and remote storage. HOST COMPUTE DOMAIN CPU Application execution Operating system and business logic GPU AI and parallel computation Training and inference workloads PCIe FABRIC Arm cores Infrastructure OS DOCA services NVIDIA BlueField DATA PROCESSING UNIT Programmable infrastructure acceleration ConnectX Packet processing Hardware steering DATA CENTRE NETWORK REMOTE STORAGE FABRIC
Compute and networking Infrastructure processing PCIe and storage
Conceptual architecture illustrating processing domains and logical connectivity, rather than a physical chip floorplan or mandatory packet path.

Modern servers do more than execute applications

A modern data centre server is responsible for far more than running application code. Every virtual machine, container, database and distributed AI workload depends on an underlying infrastructure responsible for moving, protecting and managing data.

Network packet processing, virtual switching, storage access, encryption, firewall enforcement, traffic classification and infrastructure telemetry all consume processing resources. Traditionally, many of these responsibilities have been performed by software running on the host CPU, assisted by conventional network and storage hardware.

As network bandwidth increases and infrastructure becomes more distributed, the cost of these operations becomes increasingly significant. A server may have substantial computational capacity, yet a portion of that capacity must be reserved for the infrastructure that enables applications to operate.

This creates an architectural challenge. How can a data centre increase network throughput, strengthen security and accelerate storage without continually consuming more general-purpose CPU resources?

The Data Processing Unit introduces a dedicated infrastructure processing domain, allowing selected networking, storage and security operations to execute independently of the host application processing domain.

Three complementary processing architectures

CPU

General-purpose computing

Executes operating systems, application logic, orchestration processes and general-purpose computational workloads.

GPU

Parallel computation

Accelerates highly parallel workloads such as AI training, inference, matrix operations and scientific computing.

DPU

Infrastructure processing

Combines programmable processing with specialised acceleration for networking, storage, security and infrastructure services.

From CPU-centric infrastructure to dedicated offloading

NVIDIA BlueField combines an embedded Arm processing environment, ConnectX networking technology and specialised hardware acceleration capabilities within a programmable infrastructure platform.

Rather than treating the network interface as simply a mechanism for transmitting and receiving Ethernet or InfiniBand traffic, the DPU can participate in infrastructure policy enforcement, data movement and service execution.

TRADITIONAL CPU-CENTRIC MODEL
HOST CPU
Applications
Business logic
Virtual switching
Firewall processing
Storage stack
Tunnel processing
↕
NETWORK INTERFACE
Application and infrastructure processing share host resources. Conventional NICs may still accelerate selected operations.
DPU-ACCELERATED MODEL
HOST CPU
Applications
Business logic
↕
BLUEFIELD DPU
Network offload
Security policy
Storage offload
Infrastructure OS
Supported infrastructure operations move to dedicated processing resources, subject to software configuration and hardware capabilities.

The important distinction is that a DPU does not eliminate the host CPU or replace the GPU. Instead, it introduces another processing domain designed specifically for infrastructure responsibilities.

When a supported operation is offloaded into dedicated hardware, the host may no longer need to execute the corresponding software processing for every packet or storage request. This can reduce CPU utilisation, improve throughput and reduce processing overhead. The actual benefit depends on workload characteristics, software integration and the proportion of traffic eligible for offloading.

What makes BlueField a DPU?

Component Architectural responsibility
Arm processing cores Execute embedded operating systems, infrastructure applications and control services.
ConnectX networking Provides high-speed network connectivity, packet processing, flow steering and supported transport acceleration.
Hardware accelerators Accelerate supported operations such as cryptography, data movement and packet processing without relying exclusively on general-purpose CPU execution.
PCIe connectivity Connects the DPU to the host system and enables communication, device exposure and data movement within the server architecture.
Onboard memory Supports the embedded processing environment, infrastructure applications and local data structures.
NVIDIA DOCA Provides software libraries, APIs, tools and services for developing and deploying accelerated infrastructure applications.

Why DPUs matter in modern data centres

NET

Accelerated networking

Offload eligible forwarding, packet classification, virtual switching and tunnel processing operations into dedicated network hardware.

SEC

Infrastructure security

Establish an infrastructure enforcement domain that can operate separately from host applications, supporting isolation and distributed security.

I/O

Storage acceleration

Support accelerated remote storage access, storage virtualisation and selected data movement operations using dedicated infrastructure resources.

AI

AI infrastructure

Reduce infrastructure overhead around GPU workloads and support high-performance communication and storage architectures in distributed AI systems.

K8S

Cloud-native platforms

Integrate dedicated infrastructure processing with Kubernetes, virtualised networking and multi-tenant cloud environments.

OBS

Infrastructure observability

Collect supported network and hardware telemetry from infrastructure processing domains to assist performance analysis and troubleshooting.

Offloading changes the troubleshooting model

Introducing a DPU changes where infrastructure state exists and where processing decisions are made. A packet may be classified by hardware, forwarded through an embedded switching pipeline, redirected to an Arm application or delivered to the host.

Consequently, traditional host-based monitoring may provide only a partial view of the infrastructure. Engineers must understand hardware flow tables, representor interfaces, embedded software services, PCIe connectivity and accelerator-specific counters.

A successful deployment therefore requires more than installing a new network adapter. It requires an understanding of processing ownership, infrastructure trust boundaries, software lifecycle management and the relationship between control-plane programming and hardware data-plane execution.

IMPORTANT ARCHITECTURAL DISTINCTION

Hardware-offloaded traffic does not necessarily traverse the Arm CPU for every packet. The embedded processing environment can configure and manage hardware processing rules while eligible traffic follows an accelerated data path. Unsupported operations, exceptions and selected services may require software processing. The exact behaviour depends on the configured operating mode, firmware, software stack and offload capabilities.

GENERATION AND CONFIGURATION SCOPE

This engineering guide uses BlueField-3 as its principal architectural reference. BlueField generations, adapter models and operating modes differ in processor resources, network interfaces, acceleration capabilities and supported software features. Architectural examples are conceptual and should not be interpreted as universal product specifications.

What this engineering guide will teach you

01 Understand the architectural purpose of a DPU and its relationship to CPUs, GPUs and SmartNICs.
02 Explore BlueField hardware components and internal infrastructure processing domains.
03 Trace packet classification, hardware steering and accelerated forwarding decisions.
04 Understand DOCA and programmable infrastructure application development.
05 Investigate infrastructure isolation, microsegmentation and security enforcement.
06 Examine accelerated storage, NVMe-oF and remote data movement.
07 Understand DPU integration within distributed AI and GPU infrastructure.
08 Explore cloud-native infrastructure and Kubernetes DPU integration.
09 Investigate offload failures, hardware counters and production performance issues.
Understanding BlueField is not simply about learning another network adapter. It is about understanding how modern infrastructure distributes computation, data movement and security across specialised processing domains.
NETWORK INSIGHT — ENGINEERING GUIDES BLUEFIELD DPU / INTRODUCTION
Network Insight
NVIDIA BlueField DPU Architecture
SILICON OFFLOAD EDITION
SECTION 01 / PROCESSING FOUNDATIONS

Understanding Data Processing Units

Understanding why modern data centres distribute application computation, parallel processing and infrastructure services across different hardware processing architectures.

THE FIVE PROCESSING ARCHITECTURES
Conceptual processor classifications. SmartNIC and DPU terminology overlaps across hardware vendors and implementation architectures.
THE COMPUTATIONAL SHIFT

Why infrastructure needs its own processor

The architecture of modern computing has evolved through a continuous process of specialisation. General-purpose processors remain essential, but increasingly demanding workloads have encouraged the development of hardware designed to accelerate particular categories of computation.

The Graphics Processing Unit is one example. Originally associated with graphics rendering, GPUs became fundamental to scientific computing and artificial intelligence because of their ability to execute highly parallel mathematical operations.

Data Processing Units represent another form of specialisation. Their principal focus is not application logic or neural network computation, but the infrastructure responsible for transporting, securing, storing and managing application data.

This infrastructure becomes increasingly important as organisations deploy distributed applications, virtual machines, container platforms, remote storage systems and large GPU clusters.

Every application depends on services that may not directly contribute to its business computation. Network forwarding, packet encapsulation, firewall enforcement, storage access and infrastructure telemetry are necessary operations, but they also consume resources.

The DPU changes the server architecture by introducing dedicated resources for infrastructure computation, rather than requiring every infrastructure service to compete with applications for host CPU execution.
INFRASTRUCTURE OVERHEAD

Understanding the cost of moving data

Consider a virtualised server receiving traffic from a remote application. Depending on the deployment, an incoming packet may require tunnel decapsulation, virtual switch processing, security policy evaluation, connection tracking and delivery to the appropriate virtual machine or container.

If these operations are implemented primarily in host software, the CPU must execute instructions, access memory and manipulate data structures associated with the packet processing path.

At high packet rates, infrastructure processing may consume a substantial proportion of available CPU resources. The overhead is influenced by packet size, traffic patterns, cache behaviour, interrupt handling, memory locality and the complexity of configured network services.

01. Network processing

Packet parsing, virtual switching, tunnel handling, flow classification and forwarding decisions.

02. Security processing

Firewall rules, encryption, connection tracking, access policies and traffic isolation.

03. Storage processing

Storage protocol handling, request processing, data movement and virtual storage interfaces.

04. Virtualisation

Virtual network interfaces, device emulation, tenant separation and infrastructure switching.

05. Data movement

Buffer management, DMA coordination, memory access and movement of data between devices.

06. Infrastructure telemetry

Flow statistics, hardware counters, operational monitoring and infrastructure service reporting.

NETWORK HARDWARE EVOLUTION

From conventional NICs to infrastructure processors

Network adapters have supported hardware acceleration for many years. Features such as checksum offload, segmentation offload, receive-side scaling and direct memory access reduce the amount of work performed by the host.

SmartNICs extend this model by introducing more advanced programmable packet processing and infrastructure acceleration. DPUs can extend the processing model further by providing an embedded compute environment capable of running independent infrastructure services.

EVOLUTION OF PROCESSING OWNERSHIP
ARCHITECTURE 01

Conventional NIC

HOST CPU
Application workloads
Virtual switching
Security policy
Storage services
Infrastructure control
PCIe
NIC HARDWARE
Transmit / Receive
Basic protocol offloads
DMA and queues
The host retains responsibility for many infrastructure services while the NIC accelerates supported networking operations.
ARCHITECTURE 02

SmartNIC

HOST CPU
Application workloads
Infrastructure control
Selected software services
PCIe
PROGRAMMABLE NETWORK HARDWARE
Flow classification
Virtual switch acceleration
Tunnel processing
Network I/O
More packet processing operations can execute in programmable network hardware. Capabilities depend on the particular SmartNIC architecture.
ARCHITECTURE 03

BlueField DPU

HOST CPU
Application workloads
Business computation
Host operating system
PCIe
DEDICATED INFRASTRUCTURE DOMAIN
Embedded Arm environment
ConnectX hardware processing
Infrastructure security
Storage and data acceleration
Supported infrastructure services and hardware processing can operate within a dedicated processing and management environment.
Illustrative evolution of infrastructure processing. The boundaries between NICs, SmartNICs and DPUs are not universal product classifications.
PROCESSOR RESPONSIBILITIES

CPU, GPU, NIC, SmartNIC and DPU compared

Processor Primary responsibility Typical processing model Example workloads
CPU General-purpose computation Flexible instruction execution Operating systems, applications, orchestration
GPU Parallel computation Large-scale parallel execution AI training, inference, matrix operations
NIC Network connectivity Dedicated network hardware and protocol offloads Packet I/O, checksums, DMA, segmentation
SmartNIC Programmable network acceleration Programmable pipelines, processors or logic Flow steering, tunnel handling, virtual switching
DPU Dedicated infrastructure processing Embedded compute combined with specialised networking and acceleration hardware Networking, storage, security and infrastructure services

A DPU should not be understood as a faster replacement for every other processor. Its value arises from assigning infrastructure responsibilities to hardware and software environments suited to those operations.

BlueField combines multiple processing capabilities within one platform. Its embedded Arm environment provides general-purpose infrastructure computation, while ConnectX and specialised accelerators provide dedicated data-path capabilities.

RESOURCE RECLAMATION

Returning CPU capacity to applications

One motivation for DPU deployment is the potential to reclaim host CPU resources previously consumed by infrastructure processing.

Consider a simplified server with a normalised processing capacity of 100 units. Assume that application workloads consume 55 units, network processing consumes 20 units, security processing consumes 15 units and storage processing consumes 10 units.

If supported infrastructure operations are successfully offloaded, some of those CPU resources may become available for additional application computation.

CONCEPTUAL HOST CPU RESOURCE MODEL
CPU-centric infrastructure 100 normalised resource units
DPU-accelerated infrastructure Illustrative partial offload
Application computation Reclaimed host capacity Networking Security Storage
Hypothetical educational resource model. Values are not NVIDIA benchmarks or measured BlueField performance results.

In this example, 30 resource units have been reclaimed from the host infrastructure workload. The original application workload remains unchanged, but additional CPU capacity is potentially available.

This does not mean that infrastructure computation has disappeared. The corresponding operations are now performed by DPU hardware, embedded software or a combination of both.

PERFORMANCE ENGINEERING CONSIDERATION

CPU savings do not automatically translate into proportional application throughput improvements. Applications may remain constrained by memory bandwidth, storage latency, GPU availability, network congestion or software synchronisation. Offloading should be evaluated using end-to-end workload measurements.

PROCESSING OWNERSHIP

Understanding control-plane and data-plane separation

One of the most important architectural distinctions within BlueField is the separation between programming infrastructure behaviour and executing that behaviour against traffic.

The embedded Arm processing environment can run infrastructure applications and control services. These services may configure supported hardware processing rules using appropriate software interfaces.

Once a rule has been successfully installed in a supported hardware pipeline, matching packets may be processed directly by dedicated network hardware without requiring the Arm processor to execute software instructions for every packet.

BLUEFIELD PROCESSING DOMAINS
Conceptual DPU control and data-plane architecture An embedded Arm control environment programs a ConnectX hardware pipeline. Matching packets use the hardware path to the host. Selected exceptions may be redirected to software processing. HOST APPLICATION DOMAIN Virtual machines / containers / applications BLUEFIELD INFRASTRUCTURE DOMAIN ARM CONTROL ENVIRONMENT Infrastructure applications DOCA and control services Embedded operating system Policy and service execution CONNECTX HARDWARE PATH Host delivery / DMA Match / action processing Packet parsing and classification Network ingress Program Exceptions PCIe / host delivery DATA CENTRE NETWORK Separate processing responsibilities
Green: conceptual accelerated packet path. Gold: control-plane programming. Orange: selected software exception handling. Actual pipeline ordering and supported actions depend on configuration and hardware capabilities.

This distinction explains why DPU performance is not determined solely by the performance of its embedded Arm processor.

When a workload is eligible for hardware acceleration, specialised processing engines may execute the required operations independently of the embedded software execution path.

Conversely, traffic requiring unsupported actions or complex software services may consume embedded processor resources. Depending on the deployment, unsupported operations may instead fall back to host processing, be redirected or be rejected.

THE OFFLOAD LIFECYCLE

How an infrastructure operation becomes accelerated

01

Define infrastructure behaviour

An infrastructure application determines the required behaviour, such as forwarding traffic matching a particular flow or applying a supported packet transformation.

02

Translate policy into processing rules

The software stack translates the desired behaviour into match criteria and actions suitable for the underlying processing architecture.

03

Validate hardware eligibility

The requested match fields, actions, resource requirements and pipeline placement must be supported by the hardware and software stack.

04

Install hardware processing state

Eligible rules are programmed into the appropriate hardware tables or acceleration resources. Successful installation should be verified rather than assumed.

05

Process matching traffic

Incoming packets matching installed rules can execute supported actions within the hardware data path.

06

Observe counters and exceptions

Engineers examine hardware counters, rule installation status, software fallback and resource utilisation to confirm that traffic follows the intended processing path.

ARCHITECTURAL ADVANTAGES

Why dedicated infrastructure processing matters

CPU efficiency

Reduce host processing requirements for supported infrastructure operations and potentially reclaim CPU resources for applications.

Data-path acceleration

Execute eligible packet and data processing operations using specialised hardware resources.

Infrastructure isolation

Establish a separate infrastructure processing environment with independently managed services and supported trust boundaries.

Multi-tenant infrastructure

Support virtual network interfaces, tenant isolation and distributed infrastructure policy enforcement.

Operational consistency

Standardise selected infrastructure services across different host application environments, subject to integration requirements.

Programmable services

Develop infrastructure applications that combine embedded software execution with supported hardware acceleration capabilities.

PRODUCTION ENGINEERING

What a DPU does not automatically solve

Dedicated infrastructure processing introduces opportunities for acceleration and isolation, but it also introduces additional operational complexity.

Engineers must manage firmware, embedded operating systems, infrastructure applications, hardware resources, software compatibility and the lifecycle of offloaded processing rules.

Engineering challenge Architectural implication
Unsupported operations Some processing actions cannot execute within the available hardware pipeline.
Finite hardware resources Flow tables, queues, memory and acceleration resources have capacity limits.
Software fallback Traffic may require embedded or host software processing, depending on the configured architecture.
PCIe and memory bottlenecks End-to-end performance remains dependent on the complete server data path.
Management complexity The DPU introduces additional software, firmware and infrastructure service lifecycle requirements.
Security configuration Hardware isolation does not automatically establish a secure deployment. Trust boundaries, management access and policies must be correctly configured.
Cost and power Dedicated processing hardware consumes power and introduces acquisition and operational costs that must be justified by workload benefits.
THE CORRECT ENGINEERING QUESTION

Do not ask only whether a server contains a DPU. Ask which infrastructure operations have been offloaded, where processing state resides, which hardware resources are being consumed, how exceptions are handled and whether the expected workload improvement has been measured.

ENGINEERING TAKEAWAY

The DPU as a third computational domain

Modern accelerated infrastructure can be understood as a collaboration between multiple processing architectures. CPUs provide flexible application computation, GPUs accelerate parallel workloads and DPUs provide dedicated infrastructure processing.

NVIDIA BlueField implements this infrastructure processing model through embedded Arm computation, ConnectX networking, specialised acceleration capabilities and the DOCA software ecosystem.

Understanding the relationship between these components is essential before examining the detailed hardware architecture, packet processing pipelines and programmable infrastructure services that follow in this engineering guide.

CPUs execute applications. GPUs accelerate parallel computation. DPUs accelerate and manage selected infrastructure operations that allow applications and distributed systems to communicate, access data and operate securely.
NETWORK INSIGHT — ENGINEERING GUIDES BLUEFIELD DPU / SECTION 01
Network Insight / Interactive Engineering 01

CPU vs DPU
Workload Offload Explorer

Explore how programmable infrastructure processors change the allocation of computing resources inside modern data centre servers.

SILICON OFFLOAD EDITION BLUEFIELD-3 REFERENCE INTERACTIVE RESOURCE MODEL
01 / Processor intelligence

Understand the processing architecture

CPU — Central Processing Unit

02 / Configuration

Infrastructure controls

Server architecture
Eligible offload services
Workload profiles
03 / Live architecture
DPU OFFLOAD ENABLED
SERVER / LOGICAL PROCESSING DOMAINS HOST COMPUTE DOMAIN HOST CPU CPU demand: 0 APPLICATION WORKLOAD Requested capacity: 55 GPU / ACCELERATOR Optional compute device INFRASTRUCTURE DOMAIN BLUEFIELD DPU Programmable infrastructure NETWORK PROCESSING SECURITY SERVICES STORAGE SERVICES PORTS PCIe DATA CENTRE FABRIC CONCEPTUAL MODEL NOT A PHYSICAL DIE MAP
Application processing Host infrastructure Offloaded processing
Host CPU demand
0%

Relative to modelled capacity

CPU demand removed
0

Host capacity units

Application headroom
0

After infrastructure demand

Unserved application
0

Capacity units above budget

04 / Comparative resource allocation

Where does the host CPU capacity go?

Conventional CPU + NIC 0%
BlueField-enabled architecture 0%
Infrastructure Served application demand Unallocated capacity

05 / Model telemetry

Infrastructure resource console

Educational telemetry generated by the resource model, not actual DOCA or BlueField command output.

06 / Engineering intelligence

Interpret the architecture

07 / Engineering challenge

Recover application capacity

A server is experiencing CPU contention because infrastructure services compete with application processing. Enable suitable offload services to restore the application workload.

Target: serve all 75 application capacity units while keeping total host CPU demand at or below 95 units.

Load the challenge to begin your investigation.
08 / Simulation methodology

Understand the resource model

The host CPU has a normalised capacity of 100 units. Application, networking, security and storage workloads consume illustrative capacity units.

Enabled networking, security and storage offloads are modelled as removing 80%, 75% and 70% of their respective host CPU demands. The model caps the total removed demand at 60 units and adds two host capacity units for coordination when offloading is active.

These coefficients are educational assumptions, not NVIDIA performance specifications. Removed host CPU demand does not directly represent DPU utilisation.

The conventional NIC baseline includes ordinary NIC functionality. The modelled infrastructure demand represents remaining host-side processing. Actual offload eligibility depends on hardware, software, protocol support and configuration.

The GPU is shown as an optional application accelerator. GPU utilisation, PCIe bandwidth, memory contention, queueing and DPU execution latency are outside this introductory model.

NETWORK INSIGHT
Engineering Guide 06 / Silicon Offload Edition
Network Insight
NVIDIA BlueField DPU Architecture
SILICON OFFLOAD EDITION
SECTION 02 / INTERNAL HARDWARE ARCHITECTURE

Inside the Silicon BlueField Hardware Architecture

Exploring the embedded processors, programmable networking hardware, memory systems, PCIe interfaces and specialised acceleration engines that form the foundation of NVIDIA BlueField infrastructure processing.

BLUEFIELD — CONCEPTUAL SILICON CUTAWAY
Conceptual BlueField internal hardware architecture A logical DPU architecture showing host PCIe connectivity, Arm processing, onboard memory, ConnectX networking, an embedded switch, acceleration capabilities and external network ports. This is not a physical semiconductor floorplan. HOST PCIe ROOT COMPLEX Host memory / CPU / supported peer devices DPU BOARD ONBOARD DDR MEMORY MEMORY MEMORY MEMORY BLUEFIELD SoC PCIe INTERFACE / DEVICE FUNCTIONS Host connectivity and supported device exposure ARM PROCESSING DOMAIN ARM ARM ARM ARM ARM ARM ARM ARM Embedded OS / DOCA applications CONNECTX NETWORKING Packet processing Embedded switching Transport acceleration LOGICAL INTERNAL INTERCONNECT CRYPTO Supported security acceleration DATA MOVEMENT DMA and supported data operations ACCELERATORS Generation-specific processing resources BOARD SERVICES Boot / firmware resources Management interfaces Power / thermal monitoring NETWORK PORT INTERFACE NETWORK PORT A NETWORK PORT B
Embedded processing Network processing PCIe and security Memory and data movement
Conceptual functional architecture using BlueField-3 as the principal reference. Block positions, internal connections, core illustrations and port arrangements are educational abstractions, not an exact silicon floorplan or adapter specification.
ARCHITECTURAL FOUNDATIONS

BlueField is more than a network interface

A conventional network interface provides connectivity between a server and an external network. Although modern network adapters already contain substantial hardware acceleration capabilities, their primary role remains network communication.

NVIDIA BlueField extends this architectural model by combining high-performance networking with embedded general-purpose processing, local memory and specialised acceleration resources.

This combination enables the DPU to execute infrastructure software while simultaneously providing dedicated hardware paths for supported data processing operations.

BlueField is therefore best understood as a heterogeneous infrastructure processing platform. Different internal components perform different categories of work, and software determines how those components cooperate.

The architectural strength of BlueField comes from combining programmable infrastructure computation with specialised hardware execution, rather than relying on a single processor to perform every operation.
ARM

Embedded computation

Provides an independent software execution environment for infrastructure applications, control services and management functions.

CX

ConnectX networking

Provides network connectivity, packet processing, embedded switching and supported transport acceleration capabilities.

PCIe

Host connectivity

Connects the DPU to host resources and exposes supported device functions, queues and communication mechanisms.

DDR

Local memory

Supports the embedded operating system, infrastructure applications, buffers and software-managed data structures.

ACC

Hardware acceleration

Executes supported security, data movement and other specialised processing operations using dedicated hardware resources.

MGT

Management infrastructure

Supports device initialisation, firmware, configuration, monitoring and operational lifecycle management.

EMBEDDED COMPUTE DOMAIN

The Arm processing environment

One of the defining architectural characteristics of BlueField is its embedded Arm processing subsystem. This provides a general-purpose execution environment capable of running infrastructure software separately from the host operating system.

BlueField-3 incorporates 16 Arm Cortex-A78 processor cores. These cores support embedded software execution, infrastructure service management and programmable processing tasks.

BLUEFIELD-3 — ARM PROCESSING SUBSYSTEM
ARM CORTEX-A78 COMPLEX
CACHE / MEMORY SUBSYSTEM

Independent infrastructure execution

The embedded processing environment can run Linux-based infrastructure software and DOCA applications, depending on the configured BlueField operating mode and software stack.

Infrastructure services can configure hardware processing rules, manage device resources, collect telemetry and execute selected software-based processing operations.

The Arm subsystem complements the hardware data plane rather than necessarily processing every packet received by the DPU.

Sixteen cores are illustrated for BlueField-3. Their arrangement and animated activity are conceptual and do not represent the actual semiconductor layout or scheduler behaviour.

The presence of an embedded operating system changes the operational relationship between the host and the network interface.

Instead of requiring every infrastructure application to execute within the host operating system, selected services can execute inside the DPU environment. In appropriately configured DPU deployments, this supports separation between host workloads and infrastructure management responsibilities.

ARM PROCESSING IS NOT THE ENTIRE DATA PATH

A packet handled by an installed hardware forwarding rule does not necessarily execute software on an Arm core. Embedded software may establish the processing behaviour, while the ConnectX hardware executes eligible actions directly.

NETWORK PROCESSING DOMAIN

ConnectX networking architecture

ConnectX technology provides the networking foundation of BlueField. It incorporates specialised capabilities for high-speed packet transmission, reception, classification, steering and supported protocol acceleration.

BlueField-3 integrates ConnectX-7 networking technology. Depending on the adapter model and configuration, BlueField-3 platforms support high-speed Ethernet or InfiniBand connectivity, with networking bandwidth reaching up to 400 Gb/s on supported configurations.

Network bandwidth alone does not explain the value of the architecture. The important capability is the ability to process supported network operations in dedicated hardware while maintaining programmable control over infrastructure behaviour.

CONCEPTUAL CONNECTX INGRESS PIPELINE
STAGE 01
Network ingress
Receive frames or packets from the network.
STAGE 02
Header parsing
Identify supported protocol and header fields.
STAGE 03
Classification
Match traffic against programmed processing rules.
STAGE 04
Hardware action
Execute eligible forwarding or transformations.
STAGE 05
Delivery
Direct traffic to the selected destination.
Simplified logical pipeline. Real processing paths, table ordering and available actions depend on protocol, operating mode and hardware configuration.

Packet classification

Identify supported header fields and associate traffic with programmed processing behaviour.

Flow steering

Direct matching traffic towards appropriate queues, device functions, ports or supported processing destinations.

Tunnel processing

Accelerate supported encapsulation and decapsulation operations when configured through compatible software.

RDMA capabilities

Support direct data placement and remote memory operations through compatible RDMA transports and registered memory resources.

Traffic management

Provide supported queueing, scheduling and congestion-related capabilities according to the network transport and configuration.

Hardware telemetry

Expose operational statistics and counters that help engineers investigate traffic behaviour and resource utilisation.

HOST INTERCONNECT

PCIe connectivity and host communication

Peripheral Component Interconnect Express, or PCIe, provides the high-speed communication fabric between the DPU and the host server.

BlueField-3 supports PCIe Gen5 connectivity, although the actual negotiated link width and speed depend on the adapter, server platform, slot configuration and supported deployment topology.

PCIe is responsible for more than transferring packet payloads. It provides the mechanisms through which devices expose functions, exchange control information, access permitted memory regions and notify software of completed operations.

HOST — PCIe — DPU COMMUNICATION
HOST SYSTEM HOST CPU Drivers and application execution HOST MEMORY Buffers / descriptors / registered regions PCIe ROOT COMPLEX Device connectivity and transactions BLUEFIELD DPU DEVICE FUNCTIONS Host-visible interfaces and queues DMA / DATA MOVEMENT Access to permitted memory regions PCIe INTERFACE Device-side PCIe communication PCIe transactions Bidirectional communication
Logical communication model. The diagram does not imply that every DMA operation traverses the host CPU or follows the same PCIe transaction sequence.

PCIe performance can become an important consideration in accelerated infrastructure. A high-speed network interface does not guarantee equivalent application throughput if the host interconnect, memory subsystem or software queue configuration becomes constrained.

NETWORK SPEED IS NOT APPLICATION THROUGHPUT

The end-to-end data path includes network links, PCIe connectivity, memory access, device queues, software processing and the destination workload. Each component can impose performance limitations. Advertised interface bandwidth should not be treated as a guaranteed application-level transfer rate.

MEMORY AND DATA MOVEMENT

Onboard memory, host memory and DMA

BlueField contains local memory resources that support its embedded processing environment. BlueField-3 platforms use onboard DDR5 memory, with capacity depending on the particular product configuration.

This local memory is distinct from the host server's main memory. It can contain the embedded operating system, infrastructure applications, software-managed buffers and control-plane data structures.

Hardware processing resources may also maintain dedicated internal state, queues and tables. These resources should not be assumed to reside entirely within the embedded operating system's ordinary DDR memory.

DDR

DPU-local memory

Stores embedded software, application state and local processing data. Capacity and bandwidth influence embedded workload performance.

RAM

Host memory

Contains host application buffers, operating system state, device descriptors and permitted memory regions used by connected devices.

DMA

Direct memory access

Allows supported device operations to transfer data without requiring the CPU to copy every byte through software instructions.

DMA does not mean unrestricted access to arbitrary memory. Device permissions, memory mappings, IOMMU configuration, driver behaviour and platform security mechanisms determine which memory regions are accessible.

In supported RDMA and GPUDirect deployments, network hardware may transfer data directly to registered memory regions, including compatible GPU memory. These capabilities require appropriate hardware, drivers, memory registration and topology support.

Efficient data movement depends not only on where computation occurs, but also on where data resides, which devices can access it and how many unnecessary copies are required along the processing path.
SPECIALISED HARDWARE EXECUTION

Hardware acceleration engines and programmable processing

The embedded Arm cores provide flexible software execution, but many infrastructure operations benefit from specialised processing resources.

BlueField combines multiple acceleration capabilities that can be accessed through supported drivers, firmware, libraries and infrastructure applications. BlueField-3 also introduces programmable data-path processing resources through its Data Path Accelerator, or DPA.

Processing capability Architectural purpose Example application
Flow steering Classify traffic and select supported processing destinations and actions. Virtual switching and tenant forwarding
Cryptographic acceleration Execute supported cryptographic operations using specialised hardware resources. Supported IPsec and data protection services
DMA acceleration Perform supported data transfers between appropriately mapped memory regions. Infrastructure data movement
Compression capabilities Accelerate supported compression or decompression operations where available. Selected storage and data services
RDMA transport Support direct data placement and remote memory operations. High-performance storage and distributed computing
Data Path Accelerator Execute supported programmable data-path tasks using specialised processing resources. Event-driven infrastructure processing
Embedded switching Forward traffic between supported network ports and device functions. Hardware-accelerated virtual networking

These capabilities do not necessarily represent physically separate engines arranged exactly as shown in conceptual architecture diagrams. Some functions are implemented within integrated network processing hardware, while others use distinct acceleration or programmable execution resources.

HARDWARE CAPABILITY VS SOFTWARE AVAILABILITY

A capability advertised for a hardware generation is not necessarily available through every operating mode, firmware release, DOCA library or application integration. Engineers must validate the complete hardware and software compatibility matrix before designing a production acceleration path.

VIRTUALISED NETWORK HARDWARE

Embedded switching and PCIe device functions

Modern virtualised infrastructure frequently requires a physical network adapter to provide connectivity to multiple virtual machines, containers or host software environments.

Single Root I/O Virtualisation, or SR-IOV, enables a compatible PCIe device to expose Physical Functions and Virtual Functions. These functions can provide separate device interfaces to supported workloads.

BlueField and ConnectX networking architectures also support Scalable Functions in compatible software environments. Scalable Functions provide another mechanism for creating independently managed networking function instances.

DEVICE FUNCTIONS AND EMBEDDED SWITCHING
HOST WORKLOAD DOMAIN
Host OS Physical Function
Virtual Machine A Virtual Function
Virtual Machine B Virtual Function
PCIe DEVICE CONNECTIVITY
BLUEFIELD INFRASTRUCTURE DOMAIN
PF representor Software management view
VF representor A Software management view
VF representor B Software management view
ConnectX Embedded Switch

Hardware forwarding state, supported flow rules, function connectivity and policy actions.

Physical network port A
Physical network port B
Illustrative DPU-mode networking arrangement. Representors provide software visibility and control over associated switch ports or functions. Offloaded packets do not necessarily traverse representor software interfaces.
PF

Physical Function

A PCIe function associated with device operation and supported configuration responsibilities. Management permissions depend on the deployment.

VF

Virtual Function

A lightweight PCIe function created through SR-IOV, allowing supported workloads to access dedicated virtualised device resources.

SF

Scalable Function

A supported function instance created within a parent device context, with its own allocated networking resources and software representation.

The embedded switch provides hardware connectivity between supported functions and external network ports. Infrastructure software can configure forwarding behaviour and, where supported, install hardware-offloaded network policies.

Representor interfaces are particularly important when integrating BlueField with Linux networking, Open vSwitch and hardware-offloaded infrastructure services.

A representor acts as a software representation of a hardware switch port or associated device function. It provides a mechanism through which software can manage forwarding behaviour and handle traffic that requires software processing.

INFRASTRUCTURE OWNERSHIP

Why BlueField operating modes matter

The same hardware platform can expose different operational behaviour depending on its configured operating mode.

The operating mode influences the availability of the embedded processing environment, ownership of networking resources and the relationship between host software and infrastructure management.

Mode or configuration Processing ownership Engineering implication
NIC mode The platform operates primarily as a network adapter, without the normal embedded DPU software execution model. Appropriate where network adapter behaviour is required without embedded infrastructure services.
DPU mode The embedded processing environment participates in infrastructure management and supported network resource ownership. Enables independent infrastructure services and hardware-offloaded processing architectures.
Restricted host configuration Selected host-side management permissions are restricted in supported DPU deployments. Supports stronger separation between host workloads and infrastructure administration.
MODE AND SECURITY TERMINOLOGY

Restricted host configurations, sometimes discussed in the context of zero-trust deployments, should not be confused with an automatic security guarantee. Exact mode terminology, available restrictions and management procedures depend on the BlueField generation and firmware release.

GENERATIONAL ARCHITECTURE

BlueField-2 and BlueField-3

BlueField has evolved through multiple hardware generations. Each generation introduces changes in embedded processing, network bandwidth, host connectivity and acceleration capabilities.

Architecture BlueField-2 BlueField-3
Embedded processors 8 Arm Cortex-A72 cores 16 Arm Cortex-A78 cores
Networking technology ConnectX-6 Dx ConnectX-7
Network bandwidth class Up to 200 Gb/s Up to 400 Gb/s
PCIe generation PCIe Gen4 PCIe Gen5
Onboard memory technology DDR4 DDR5
Programmable processing Embedded Arm processing and supported networking acceleration Expanded acceleration capabilities, including DPA processing resources

These are representative generation-level characteristics, not a complete product purchasing specification. Port configurations, supported network protocols, memory capacities, PCIe arrangements and acceleration features vary across individual models.

HARDWARE PROCESSING JOURNEY

How the hardware components cooperate

Consider a packet arriving from the data centre network and destined for a host virtual machine through an installed hardware-offloaded forwarding rule.

01

Network interface receives traffic

The physical network interface receives the incoming traffic and passes it into the supported network processing architecture.

02

ConnectX identifies the flow

Hardware parses supported protocol headers and evaluates the packet against installed classification and steering state.

03

Hardware applies programmed behaviour

The matching rule determines the eligible forwarding action, transformation or processing destination.

04

Embedded switch selects the destination

The hardware forwarding path directs traffic towards the appropriate host-visible device function or other configured destination.

05

Data movement delivers the payload

Supported device and DMA mechanisms place packet data into the appropriate permitted memory buffers and update completion state.

06

The destination workload consumes the data

Host software receives the data through its configured device interface and continues application processing.

Throughout this conceptual journey, the embedded Arm environment may have been responsible for establishing infrastructure policy and programming hardware state. However, the accelerated packet itself does not necessarily require Arm software processing.

Traffic that misses installed rules, requires unsupported actions or is explicitly redirected may follow a different path. The outcome depends on the configured forwarding and exception-handling behaviour.

HARDWARE TROUBLESHOOTING

Understanding where performance problems originate

BlueField introduces multiple processing domains, each with different resources and operational constraints. Troubleshooting requires identifying which component is responsible for the observed behaviour.

Observed symptom Possible processing domain Evidence to investigate
High embedded CPU utilisation Arm software processing Infrastructure processes, software exceptions, scheduling and local memory pressure
Unexpected host CPU overhead Host software or incomplete offloading Rule installation state, software fallback, driver configuration and packet processing statistics
Low transfer throughput PCIe, memory or network path Negotiated PCIe speed and width, queue statistics, congestion and application transfer characteristics
Missing virtual interface Device function configuration PF/VF/SF configuration, drivers, enumeration and representor mappings
Hardware rule installation failure ConnectX processing resources Supported match/action combinations, hardware table capacity and software logs
Unexpected packet loss Network or embedded switching Port counters, queue drops, forwarding rules, policy actions and congestion indicators
Acceleration service unavailable Firmware or software compatibility Device capabilities, firmware versions, operating mode and DOCA compatibility
ENGINEERING INVESTIGATION PRINCIPLE

A symptom does not uniquely identify its root cause. High CPU utilisation, low throughput or packet loss may originate from several interacting components. Engineers should correlate evidence across the host, embedded Arm environment, hardware counters and external network before assigning responsibility.

ENGINEERING TAKEAWAY

BlueField as a heterogeneous infrastructure processor

NVIDIA BlueField combines embedded Arm computation, ConnectX networking, PCIe connectivity, local memory, specialised acceleration capabilities and programmable infrastructure software.

These components provide different forms of execution. The Arm environment supports flexible software processing, the networking hardware supports accelerated packet operations, and specialised processing resources support additional infrastructure acceleration.

Understanding this division of responsibilities is essential for designing effective infrastructure offloading architectures and investigating production performance problems.

The DPU is not a single processing engine. It is a coordinated infrastructure architecture in which embedded software, specialised silicon, memory and network interfaces cooperate to execute supported infrastructure services.
NETWORK INSIGHT — ENGINEERING GUIDES BLUEFIELD DPU / SECTION 02
Network Insight / Interactive Engineering 02

Inside BlueField
Silicon Architecture Explorer

Enter the programmable infrastructure processor. Investigate the hardware components that combine networking, embedded computing, memory and specialised acceleration within a DPU architecture.

SILICON OFFLOAD EDITION BLUEFIELD-3 REFERENCE HARDWARE CUTAWAY INTERNAL DATA JOURNEYS
01 / Silicon inspection laboratory

Explore the processing domains

BLUEFIELD / CONCEPTUAL HARDWARE MODEL LOGICAL DOMAINS PCB / BOARD INTERCONNECT PACKAGE SUBSTRATE COMPUTE DATA PATH PROCESSING SILICON THERMAL STRUCTURE THERMAL LAYER SILICON SUBSTRATE CIRCUIT BOARD Conceptual package construction Layer spacing and geometry are illustrative NETWORK INTERFACES BLUEFIELD PROCESSING COMPLEX ARM COMPLEX Embedded CPU execution CONNECTX PACKET PROCESSING FLOW STEERING NETWORK DATA PATH Accelerated networking INTERNAL INTERCONNECT CRYPTO STORAGE RDMA / DMA DDR MEMORY MGMT BOOT CONTROL TELEMETRY PCIe HOST INTERFACE Host memory / devices / control Select a component to inspect its engineering role
Compute and data movement Networking and offload Security acceleration
02 / Internal data movement laboratory

Follow a workload through the architecture

Select a workload and observe which logical hardware domains participate in processing. These journeys illustrate architectural relationships rather than exact microarchitectural execution sequences.

Architecture event console

Illustrative event trace, not actual hardware telemetry or DOCA CLI output.

Engineering interpretation
Current processing stage
Select Run data journey to begin.
03 / Engineering architecture principles

Understand the processing boundaries

Programmable execution

The embedded Arm subsystem provides general-purpose processing for supported infrastructure applications and services. It is distinct from the host CPU.

Accelerated data path

Eligible packet operations can execute through networking hardware without requiring every packet to traverse general-purpose Arm cores.

Specialised acceleration

Supported cryptographic, storage and data-movement functions can use specialised hardware or combinations of hardware and software processing.

Separate memory domains

DPU-local memory and host memory are distinct resources. Access between domains depends on configured interfaces, permissions and mappings.

04 / Hardware architecture challenge

Identify the correct processing domain

SCORE 0 / 4

05 / Technical reference and model scope

From conceptual architecture to real hardware

BlueField-3 combines a 16-core Arm Cortex-A78 processor complex with ConnectX-7 networking technology and dedicated infrastructure acceleration capabilities.

BlueField-3 configurations can support networking speeds up to 400 Gb/s and PCIe Gen5 connectivity. Actual interface configurations, memory capacities and supported features depend on the specific product and deployment.

The storage, cryptography and RDMA blocks in this explorer represent logical functional domains. They do not imply that these capabilities are implemented as physically separate silicon blocks in the positions shown.

The management block similarly represents management responsibilities rather than a claim about a particular dedicated processor. The exploded view is a generic conceptual package construction.

Real data paths depend on operating mode, firmware, DOCA services, flow configuration, transport protocol, memory registration and hardware support.

NVIDIA Networking Technical Documentation
NETWORK INSIGHT
Engineering Guide 06 / Silicon Offload Edition
Network Insight
NVIDIA BlueField DPU Architecture
SILICON OFFLOAD EDITION
SECTION 03 / NETWORK PROCESSING

Beyond the Host CPU Network Processing and Hardware Offloading

Understanding how programmable network silicon executes forwarding, classification, virtual switching, tunnel processing and infrastructure policies without requiring general-purpose software execution for every packet.

BLUEFIELD — HARDWARE AND SOFTWARE PROCESSING DOMAINS
BlueField hardware offload architecture Network traffic enters ConnectX hardware. Installed forwarding rules may direct traffic through an accelerated path to a host function. Configured exception traffic may be redirected to embedded Arm software. Control software programs supported hardware processing rules. HOST WORKLOAD DOMAIN VIRTUAL MACHINE A HOST APPLICATION VIRTUAL MACHINE B VF / workload interface PF / supported interface VF / workload interface PCIe / DEVICE FUNCTIONS BLUEFIELD DPU CONNECTX HARDWARE DATA PLANE DEVICE FUNCTION STEERING Selected destination / queue / function HARDWARE FLOW TABLES MATCH ACTION COUNTER PACKET PARSING / CLASSIFICATION Supported protocol headers and metadata NETWORK INGRESS EMBEDDED ARM DOMAIN INFRASTRUCTURE CONTROL Policy / OVS / DOCA applications RULE MANAGEMENT Drivers / supported offload interfaces SOFTWARE PROCESSING Configured exceptions / slow path PROGRAM EXCEPTION DATA CENTRE NETWORK Incoming network traffic HARDWARE OFFLOAD PATH Illustrative processing state
Hardware forwarding Network connectivity Control-plane programming Configured software exception path
Conceptual BlueField DPU-mode architecture. Hardware processing, exception handling and control ownership depend on installed rules, firmware, operating mode and the infrastructure software stack.
ARCHITECTURAL FOUNDATIONS

What does network hardware offloading actually mean?

Modern data centre servers execute more than application workloads. They also perform infrastructure operations associated with virtual networking, security, encapsulation, traffic classification, storage access and communication between distributed systems.

When these operations execute through general-purpose software, they consume processor cycles, memory bandwidth and other host resources.

Network hardware offloading transfers supported operations into specialised processing resources designed to execute those operations efficiently. BlueField extends this model by combining programmable infrastructure software with dedicated ConnectX networking hardware.

The objective is not simply to move every infrastructure operation from the host CPU to an embedded Arm CPU. The more significant architectural opportunity is to establish supported processing behaviour in software and execute eligible operations directly in hardware.

Software defines the infrastructure behaviour. Specialised hardware executes eligible operations. The host CPU retains responsibility for the application and any processing that has not been offloaded.
CPU

Host software processing

Network operations execute through host drivers, kernel networking, virtual switches or userspace processing frameworks.

ARM

Embedded infrastructure software

Selected infrastructure services execute inside the DPU environment, providing programmable management and software processing.

HW

Hardware execution

Supported packet operations execute through installed hardware processing rules and specialised networking resources.

PACKET EXECUTION PATHS

Hardware fast paths and software slow paths

The distinction between hardware and software processing paths is fundamental to understanding accelerated network infrastructure.

A hardware fast path handles traffic using supported processing rules installed within the networking device. Eligible packets can be classified, transformed and forwarded without requiring the complete software forwarding pipeline to execute for every packet.

A software slow path handles traffic requiring additional software processing. This may include configured exceptions, unsupported operations, control protocols or packets that miss installed forwarding state.

COMPARATIVE PACKET PROCESSING ARCHITECTURE
EXAMPLE SOFTWARE FORWARDING PATH
Network adapter Packet reception
Software receive processing Driver and queue handling
Software virtual switch Classification and policy evaluation
Software packet actions Forwarding or transformation
Destination workload Application processing
Infrastructure forwarding consumes general-purpose software processing resources. The exact cost depends on the software implementation, batching, CPU architecture and existing acceleration.
EXAMPLE HARDWARE-OFFLOADED PATH
ConnectX ingress Packet reception and parsing
Hardware match/action Installed forwarding state
Embedded switch Hardware destination selection
Device function / DMA Delivery to permitted buffers
Destination workload Application processing
Eligible infrastructure forwarding executes in hardware. Software still establishes processing state, manages resources and handles operations that remain outside the offloaded path.
These are illustrative processing paths, not measured latency comparisons. Actual software and hardware execution paths vary across deployments.
A FLOW MISS DOES NOT ALWAYS MEAN SOFTWARE FALLBACK

Depending on the programmed default behaviour, an unmatched packet may be dropped, forwarded using another table, redirected to software or handled through a different configured processing path. Engineers must inspect the actual miss action rather than assuming every unmatched packet reaches the embedded Arm environment.

PROGRAMMABLE NETWORK SILICON

Hardware flow tables and match/action processing

Hardware-offloaded networking commonly uses a match/action processing model.

The match identifies traffic using supported protocol fields, ingress information or other available metadata. The action determines what the hardware should do when a packet satisfies the programmed conditions.

Multiple tables and processing stages may cooperate to implement more complex forwarding behaviour. The available matches, actions and combinations depend on the device capabilities and software interface.

CONCEPTUAL HARDWARE FLOW TABLE
CONNECTX — PROGRAMMED PROCESSING STATE
PRIORITY MATCH CONDITION ACTION DESTINATION
400 Tenant A / prohibited flow DROP None
300 VXLAN / VNI 5010 DECAP + FWD VF 01
200 VF 02 / remote tenant ENCAP + FWD Uplink
100 VF 01 / local destination FORWARD VF 03
0 Default processing REDIRECT Software
Illustrative logical rules and priorities. This is not a literal ConnectX hardware table dump. The animated highlights represent conceptual rule activity, not live traffic or measured counters.
MATCH

Packet identification

Supported Ethernet, IP, transport and tunnel fields can identify traffic requiring particular processing behaviour.

ACT

Hardware actions

Eligible actions include forwarding, dropping, counting, supported header modification and tunnel processing.

PRI

Rule precedence

Table structure, priority and pipeline ordering determine how overlapping processing conditions are resolved.

CNT

Flow counters

Supported counters provide evidence of packet and byte activity associated with installed hardware rules.

MISS

Default processing

Configured miss behaviour determines what happens when traffic does not match an applicable processing entry.

CAP

Resource capacity

Hardware tables, counters, action resources and other processing objects have finite capacity and compatibility constraints.

VIRTUAL SWITCHING ARCHITECTURE

The ConnectX embedded switch

The embedded switch, commonly referred to as the eSwitch, provides hardware connectivity between supported network ports and device functions.

In a virtualised infrastructure environment, traffic may need to move between virtual machines, physical network interfaces and infrastructure services. The embedded switch provides a hardware forwarding foundation for supported versions of these operations.

EMBEDDED SWITCH — EAST-WEST AND NORTH-SOUTH TRAFFIC
HOST VIRTUALISED WORKLOADS WORKLOAD A WORKLOAD B WORKLOAD C VF 01 VF 02 VF 03 BLUEFIELD EMBEDDED SWITCH VPORT 01 VPORT 02 VPORT 03 PROGRAMMED HARDWARE FORWARDING PHYSICAL NETWORK UPLINK LOCAL FORWARDING EXTERNAL FORWARDING
Supported local traffic may be switched between device functions without traversing the external network. External traffic follows the programmed uplink forwarding path. Both remain subject to configured policy and device capabilities.

Local forwarding can reduce the need for host-based software switching or unnecessary traversal of the external network.

However, the embedded switch does not automatically provide a complete tenant isolation architecture. Isolation depends on correctly configured forwarding state, access controls, device permissions and the broader infrastructure security model.

SOFTWARE-DEFINED NETWORKING

Open vSwitch and hardware-offloaded forwarding

Open vSwitch, or OVS, provides programmable virtual switching for many virtualised and cloud infrastructure environments.

Traditional OVS deployments execute forwarding operations through a software datapath. Hardware offloading allows eligible datapath flows to be translated into supported device processing rules.

Depending on the deployment, OVS can execute within the embedded BlueField environment and manage representor interfaces associated with device functions and physical network ports.

OVS — LOGICAL HARDWARE OFFLOAD WORKFLOW
INFRASTRUCTURE POLICY Controller / orchestration / configuration SOFTWARE CONTROL AND DATAPATH MANAGEMENT OVS CONTROL LOGIC Policy and flow translation SOFTWARE DATAPATH Processing not executed in hardware SUPPORTED OFFLOAD INTERFACE Example: TC flower / compatible driver CONNECTX HARDWARE DATAPATH MATCH TABLES HARDWARE ACTIONS FORWARDING STATE
Example Linux TC-based offload architecture. Other supported integrations, including DOCA-based and userspace datapaths, may use different programming interfaces and processing models.
01

Infrastructure policy is established

A controller, orchestrator or administrator defines the required virtual network behaviour.

02

OVS derives datapath processing state

Software translates the required forwarding behaviour into applicable datapath flow rules.

03

Offload eligibility is evaluated

The software and driver determine whether the required matches and actions can be represented using supported hardware resources.

04

Supported hardware state is installed

Eligible processing rules are programmed into the networking device through the applicable offload interface.

05

Matching packets execute in hardware

Subsequent eligible traffic can follow the installed accelerated forwarding path.

06

Operational evidence is collected

Software and hardware counters help establish whether the expected forwarding state has actually been installed and exercised.

CONFIGURED OFFLOAD IS NOT VERIFIED OFFLOAD

Enabling hardware offloading does not guarantee that every OVS flow will execute in hardware. Unsupported match/action combinations, resource constraints, driver limitations and incompatible software configurations can prevent individual flows from being offloaded.

OVERLAY NETWORK ACCELERATION

VXLAN encapsulation and decapsulation offloading

Virtual Extensible LAN, or VXLAN, allows logical Layer 2 networks to extend across an IP-based underlay network.

VXLAN encapsulates an original Ethernet frame within additional tunnel and transport headers. A 24-bit VXLAN Network Identifier, or VNI, identifies the logical overlay segment.

In software-based overlay architectures, tunnel encapsulation and decapsulation may consume host processing resources. Compatible BlueField networking hardware can accelerate supported tunnel operations when the required processing state is installed.

VXLAN — ANIMATED PACKET HEADER ARCHITECTURE
ORIGINAL INNER ETHERNET FRAME
Inner Ethernet Source / destination MAC
Inner IP Tenant addressing
TCP / UDP Transport header
Payload Application data
SUPPORTED HARDWARE ENCAPSULATION
VXLAN ENCAPSULATED NETWORK PACKET
Outer ETH 14 bytes*
Outer IP 20 bytes*
UDP 8 bytes
VXLAN 8 bytes / VNI
Inner frame Original Ethernet frame
*Illustrative Ethernet and IPv4 header sizes without VLAN tags or IP options. VXLAN adds 50 bytes relative to the inner Ethernet frame in this example, excluding FCS and physical-layer overhead. IPv6, VLAN tags and additional headers change the total overhead. Visual field widths are not proportional to byte length.
ENC

Tunnel encapsulation

Eligible hardware actions add the configured outer headers required to transport the inner Ethernet frame across the underlay.

DEC

Tunnel decapsulation

Supported incoming tunnel traffic is classified and the appropriate outer headers are removed before further forwarding.

VNI

Overlay classification

Supported tunnel identifiers and metadata help associate traffic with the intended logical network and processing policy.

Hardware tunnel processing does not remove the requirement for correct overlay configuration. Remote tunnel endpoint reachability, VNI mappings, underlay routing, neighbour resolution and MTU configuration remain essential.

OFFLOADING DOES NOT ELIMINATE ENCAPSULATION OVERHEAD

Hardware acceleration changes where the encapsulation operation executes. It does not remove the additional headers transmitted across the physical network. Underlay MTU must still accommodate the required encapsulated packet size.

VIRTUALISED DEVICE CONNECTIVITY

SR-IOV, representors and accelerated workload networking

Single Root I/O Virtualisation enables a compatible PCIe device to expose multiple Virtual Functions associated with a Physical Function.

A virtual machine can be assigned a supported Virtual Function, allowing network communication through a device interface without requiring every packet to traverse a conventional host software virtual switch.

Representor interfaces provide infrastructure software with a management and processing view of associated embedded switch ports and device functions.

Combining SR-IOV connectivity with hardware-offloaded switching can provide direct workload access while retaining programmable infrastructure forwarding and policy capabilities.

Architecture Primary mechanism Engineering consideration
Software virtual switching Software executes virtual network forwarding. Flexible processing with general-purpose CPU resource requirements.
SR-IOV device access Supported workloads access assigned PCIe Virtual Functions. Requires compatible device configuration, drivers and isolation mechanisms.
Embedded switch offload Hardware executes supported forwarding and policy actions. Requires compatible rule installation and sufficient hardware resources.
Representor-based management Software manages associated hardware switch ports or functions. Correct function mapping and processing ownership are essential.
SR-IOV provides virtualised device connectivity. Representors provide software visibility and control. Hardware offloading provides accelerated execution. These are complementary architectural mechanisms, not interchangeable terms.
PRODUCTION RESOURCE ENGINEERING

Hardware flow capacity and offload limitations

Hardware acceleration introduces its own resource constraints. Flow tables, counters, processing objects, queues and supported action combinations cannot be treated as unlimited resources.

Large cloud environments may create significant forwarding state as virtual machines, containers, network policies and overlay endpoints change.

A production offload architecture must account for both steady-state forwarding requirements and the rate at which processing state changes.

Flow table scale

The amount of supported processing state depends on rule complexity, table organisation, device resources and firmware.

Rule installation rate

Frequent workload changes and short-lived connections may increase the rate of hardware programming operations.

Action compatibility

Individual actions may be supported while particular combinations of matches and actions remain unavailable.

Counter resources

Detailed flow accounting may consume dedicated hardware resources and introduce additional operational management requirements.

Exception processing

Large volumes of traffic redirected to software can create processing bottlenecks outside the accelerated data path.

Resource exhaustion

Insufficient hardware resources may cause rule installation failures, software processing or other configured failure behaviour.

PERFORMANCE ARCHITECTURE

Why packets per second matter

Network throughput is often expressed in gigabits per second. However, infrastructure processing cost is frequently influenced by the number of packets requiring classification and forwarding.

At a given network bit rate, smaller packets create a substantially higher packet processing rate than larger packets.

This is one reason why dedicated networking silicon can be particularly valuable in environments with high packet rates and repetitive processing operations.

Ethernet frame size 100 Gb/s 200 Gb/s 400 Gb/s
64 bytes 148.81 Mpps 297.62 Mpps 595.24 Mpps
512 bytes 23.50 Mpps 46.99 Mpps 93.98 Mpps
1518 bytes 8.13 Mpps 16.25 Mpps 32.51 Mpps
9018 bytes 1.38 Mpps 2.77 Mpps 5.53 Mpps
THEORETICAL ETHERNET LINE-RATE CALCULATIONS

Values use the nominal Ethernet bit rate divided by eight times the frame size plus 20 bytes of preamble, start-frame delimiter and inter-frame gap. Frame sizes include the Ethernet FCS. These are theoretical packet rates, not measured BlueField forwarding performance or guaranteed application throughput.

Engineers should evaluate throughput, packet rate, flow complexity, latency, CPU utilisation and hardware resource consumption together.

A device may achieve different forwarding performance depending on the packet size distribution and the specific processing operations required.

OPERATIONAL EVIDENCE

Verifying hardware offloading in production

Hardware offloading should be verified through operational evidence rather than inferred from configuration alone.

In a compatible Linux and Open vSwitch environment, engineers can inspect the configured offload state, datapath flows, representor interfaces, traffic-control filters and device counters.

BLUEFIELD — EXAMPLE READ-ONLY INVESTIGATION
# Inspect OVS hardware-offload configuration
ovs-vsctl get Open_vSwitch . other_config:hw-offload

# Inspect configured bridges and interfaces
ovs-vsctl show

# Inspect datapath flows
ovs-appctl dpctl/dump-flows

# Request offloaded flows on supported OVS versions
ovs-appctl dpctl/dump-flows type=offloaded

# Discover device ports and representor relationships
devlink port show

# Inspect available network interfaces
ip -br link

# Inspect TC ingress filters on the relevant representor
tc -s filter show dev REPRESENTOR ingress

# Inspect network device statistics
ethtool -S INTERFACE

# Inspect supported embedded-switch mode
devlink dev eswitch show pci/PCI_ADDRESS
Illustrative inspection commands for compatible Linux, OVS and mlx5 environments. Replace placeholders with actual interface names and PCI addresses. Command availability, output fields, permissions and execution location depend on the installed software and BlueField operating mode.

The investigation should establish whether the expected processing rule exists, whether it has been successfully offloaded and whether traffic counters indicate that the intended packets are actually exercising the rule.

Observed symptom Possible cause Evidence to investigate
High host CPU utilisation Software forwarding, workload processing or incomplete offloading. CPU profiling, datapath flow state and device statistics.
High embedded Arm utilisation Infrastructure service load or software exception processing. Embedded process statistics, exception counters and software datapath activity.
Flow not offloaded Unsupported processing combination or unavailable hardware resources. OVS flow state, TC filter state, driver messages and supported capabilities.
VXLAN connectivity failure Incorrect tunnel mapping, underlay reachability or MTU. Tunnel configuration, route state, packet captures and interface counters.
Unexpected tenant forwarding Incorrect policy, device mapping or hardware forwarding state. Representor mapping, rule priorities, VNI associations and flow counters.
Packet capture misses traffic Hardware forwarding bypasses the selected software observation point. Hardware counters, supported mirroring and captures at appropriate network points.
Low throughput despite offload Congestion, PCIe limitations, queue pressure or workload bottlenecks. Link utilisation, queue statistics, PCIe state and application performance.
HARDWARE OFFLOADING CHANGES OBSERVABILITY

A packet forwarded entirely through an accelerated hardware path may not appear at a conventional software packet capture point. An empty capture does not necessarily indicate an absence of traffic. Engineers must select observation points appropriate to the actual forwarding architecture.

ENGINEERING TAKEAWAY

From software-defined policy to silicon execution

NVIDIA BlueField provides an infrastructure processing architecture in which programmable software and specialised networking hardware cooperate.

The embedded software environment can establish infrastructure policy, manage forwarding state and execute selected software processing operations. ConnectX networking hardware can execute supported classification, switching, encapsulation and forwarding operations through installed processing rules.

Effective production engineering requires understanding the relationship between the intended policy, the software representation of that policy, the actual hardware forwarding state and the observed behaviour of packets.

Hardware offloading is not simply a performance feature. It changes where infrastructure executes, where forwarding state resides, where failures can occur and where engineers must collect operational evidence.
NETWORK INSIGHT — ENGINEERING GUIDES BLUEFIELD DPU / SECTION 03
Network Insight / Interactive Engineering 03

Inside the Hardware
Packet Processing Pipeline

Follow packets through a programmable infrastructure data plane. Investigate classification, flow matching, hardware actions, software exceptions and forwarding decisions inside a conceptual BlueField-enabled server.

SILICON OFFLOAD EDITION MATCH-ACTION DATA PLANE VXLAN PROCESSING HARDWARE FLOW INVESTIGATION
01 / Traffic generator

Configure the incoming packet

Pipeline configuration
02 / Hardware processing chamber
PIPELINE READY
CONNECTX / LOGICAL MATCH-ACTION PIPELINE ACCELERATED DATA PLANE SOFTWARE DOMAIN INGRESS Physical port / VF / vport PACKET PARSER Extract headers and metadata FLOW TABLE Priority / match / action ACTION ENGINE Forward / modify / drop EGRESS Selected destination SOFTWARE PATH Policy / exception EMBEDDED ARM OR CONFIGURED SOFTWARE HANDLER PACKET DROP EXCEPTION MATCH ACTION DENY Conceptual processing stages — not an exact ASIC pipeline
Active packet Hardware processing Software exception Policy drop
Select a traffic scenario and inject a packet.
Injected
0
HW completed
0
SW completed
0
Dropped
0
03 / Packet disassembly laboratory

Inspect the packet before and after processing

Original ingress packet
Processed packet / disposition
No packet has completed processing.
04 / Programmable match-action rules

Inspect and modify the flow table

Rules are evaluated from highest to lowest priority. A matching rule specifies a packet action. Hardware installation state determines whether an eligible rule uses the accelerated path.

RULE PRIORITY MATCH ACTION STATE HITS
Select a rule to investigate its installation state.
05 / Data-plane evidence

Packet processing event console

Educational event trace generated by the simulation. Not actual NVIDIA firmware, DOCA or Open vSwitch command output.

06 / Engineering interpretation

Understand the forwarding decision

No forwarding decision has been made.
Hardware offload requires an eligible, correctly installed flow rule.
Counters record completed packet journeys.
Representor architecture

A representor is a software-visible interface associated with a hardware switch port, such as a VF vport. It enables policy configuration and observation without requiring every accelerated packet to traverse the representor's software path.

07 / Production engineering challenge

The missing hardware offload

An east-west application flow is being forwarded successfully, but its rule is installed only in software. Investigate the flow table and recover hardware forwarding without changing the intended packet action.

Your task is to restore the application flow to hardware while preserving the security deny rule. Validate both paths by injecting the corresponding traffic scenarios.

Load the incident to begin your investigation.
08 / Architecture and simulation scope

From match-action models to production BlueField

Hardware fast path

Supported installed rules can execute eligible matching and packet actions in the accelerated networking data plane.

Software slow path

Exceptions and non-offloaded rules may require software processing. The actual handler depends on operating mode and deployment configuration.

Tunnel processing

Eligible VXLAN operations can add or remove outer Ethernet, IP, UDP and VXLAN headers according to configured tunnel and forwarding state.

Virtual switching

Embedded switching and SR-IOV can support accelerated forwarding between configured physical and virtual ports.

This educational model uses a single ordered flow table and a simplified logical processing sequence. Real BlueField and ConnectX deployments may use multiple steering tables, metadata registers, tunnel contexts and chained processing actions.

Rule installation in this laboratory is simulated. Actual hardware eligibility depends on supported matches, actions, resource availability, firmware, driver versions and DOCA or other software integration.

The animation duration represents teaching time, not hardware latency. The packet counters are simulated events rather than performance benchmarks.

NVIDIA DOCA Technical Documentation
NETWORK INSIGHT
Engineering Guide 06 / Silicon Offload Edition
NETWORK INSIGHT
NVIDIA BlueField DPU Architecture
SILICON OFFLOAD EDITION
SECTION 04 / PROGRAMMABLE INFRASTRUCTURE

Programming the Infrastructure NVIDIA DOCA Software Architecture

Understanding how infrastructure applications, embedded Linux, software development libraries and specialised hardware engines cooperate to transform BlueField into a programmable data centre infrastructure platform.

DOCA — SOFTWARE TO SILICON ARCHITECTURE
NVIDIA DOCA software architecture Host workloads communicate with BlueField infrastructure resources. Infrastructure applications use DOCA libraries and supported device interfaces to configure networking, data movement and accelerator resources. The embedded Arm environment and specialised hardware execute different parts of the infrastructure workload. HOST APPLICATION AND ORCHESTRATION DOMAIN APPLICATION WORKLOADS ORCHESTRATION HOST-SIDE SOFTWARE PCIe / MANAGEMENT / SUPPORTED COMMUNICATION BLUEFIELD PROGRAMMABLE INFRASTRUCTURE EMBEDDED ARM SOFTWARE DOMAIN NETWORK SERVICES SECURITY SERVICES STORAGE SERVICES DOCA LIBRARIES AND APIs DOCA CORE DOCA FLOW DOCA DMA DOCA DPA EMBEDDED LINUX / DRIVERS / DEVICE INTERFACES SPECIALISED HARDWARE EXECUTION RESOURCES CONNECTX DMA ENGINES DPA RESOURCES ACCELERATORS Packet processing Data movement Programmable execution Supported operations DATA CENTRE NETWORK
Software control and programming Hardware execution Host and network connectivity
Conceptual BlueField-3-oriented DOCA architecture. The diagram represents logical software and hardware relationships rather than a mandatory API call path or literal silicon floorplan. Supported libraries, execution locations and acceleration capabilities vary by device and DOCA release.
SOFTWARE ARCHITECTURE

What is NVIDIA DOCA?

NVIDIA DOCA is a software framework and development ecosystem for building accelerated infrastructure applications using supported NVIDIA networking devices, including BlueField DPUs.

BlueField provides programmable processing resources and specialised hardware capabilities. DOCA provides software abstractions, libraries, development tools, examples and infrastructure software components that help developers use those capabilities.

Rather than requiring infrastructure developers to implement every operation directly against device registers or firmware interfaces, DOCA exposes supported programming models for operations such as network flow processing, data movement, communication and accelerator execution.

This creates an architectural separation between the infrastructure application, the programming interface and the hardware resources that execute eligible operations.

BlueField supplies the programmable infrastructure processing resources. DOCA supplies software mechanisms through which developers can configure and use supported resources.
SDK

Software development

Libraries, headers, development tools, documentation and examples support the creation of accelerated infrastructure applications.

API

Hardware programming

Supported APIs expose device resources, hardware processing operations and application execution mechanisms.

SVC

Infrastructure services

Applications and deployable software components can implement networking, security, storage and infrastructure management functions.

LAYERED PROGRAMMING MODEL

The DOCA software stack

A useful way to understand DOCA is to separate infrastructure intent from software implementation and hardware execution.

An infrastructure application defines the required behaviour. DOCA libraries provide programming abstractions for supported operations. Device interfaces and associated software components connect those abstractions to available processing resources.

LOGICAL INFRASTRUCTURE SOFTWARE STACK
INFRASTRUCTURE APPLICATIONS
Network acceleration Security processing Storage infrastructure
DOCA PROGRAMMING LIBRARIES
DOCA Core DOCA Flow DOCA DMA DOCA DPA Communication APIs Other supported libraries
SYSTEM SOFTWARE AND DEVICE INTERFACES
Linux environment Device drivers Firmware interfaces
HARDWARE EXECUTION RESOURCES
ConnectX networking Arm and DPA processing Specialised accelerators
Logical abstraction model. Individual DOCA libraries have different dependencies, execution requirements and hardware interfaces. Not every operation passes through every illustrated layer.
DOCA IS NOT A SINGLE NETWORK OPERATING SYSTEM

DOCA is a software ecosystem containing programming libraries, tools and associated infrastructure software. The embedded Linux operating environment, device firmware and infrastructure applications remain distinct architectural components.

PROGRAMMING INTERFACES

Understanding the DOCA library ecosystem

Different infrastructure operations require different programming models. Configuring a hardware network flow is not the same operation as transferring memory contents or executing a programmable accelerator function.

DOCA provides specialised libraries that expose supported mechanisms for these different categories of infrastructure processing.

CORE

DOCA Core

Common infrastructure abstractions for device discovery, memory management, buffers, contexts, tasks and progress mechanisms used by applicable DOCA libraries.

FLOW

DOCA Flow

Programming supported hardware packet processing pipelines using pipes, entries, matching conditions, actions, forwarding and monitoring mechanisms.

DMA

DOCA DMA

Submitting supported direct memory access operations between appropriately registered and accessible memory regions.

DPA

DOCA DPA

Developing and managing programmable execution on supported Data Path Accelerator resources, particularly for data-path-oriented operations.

COMM

Communication libraries

Supported communication mechanisms enable applications to exchange information across infrastructure processing domains.

ACCEL

Specialised acceleration

Additional libraries expose supported capabilities for operations such as cryptography, compression, hashing and other infrastructure processing.

RELEASE AND DEVICE COMPATIBILITY

DOCA library availability, supported operations, API names and execution environments evolve across releases. A library supported on one BlueField generation or networking device should not be assumed to provide identical capabilities on another.

COMMON INFRASTRUCTURE OBJECTS

DOCA Core: devices, memory, contexts and tasks

Accelerated infrastructure applications require more than access to a hardware processing function. They must discover suitable devices, establish accessible memory regions, describe buffers, configure execution contexts and manage operation completion.

DOCA Core provides common abstractions that support these requirements for applicable task-oriented DOCA libraries.

DOCA CORE — CONCEPTUAL RESOURCE LIFECYCLE
DEVICE DISCOVERY MEMORY MAPPING BUFFER MANAGEMENT Select capable device Register accessible regions Describe operation data EXECUTION CONTEXT Configure and start supported engine TASK SUBMISSION OPERATION EXECUTION COMPLETION HANDLING Submit configured work Supported processing resource Progress and result handling RELEASE RESOURCES AFTER OPERATIONS COMPLETE
Illustrative resource lifecycle for applicable task-based DOCA libraries. Exact object creation, configuration, progress and destruction sequences depend on the selected library and SDK release.
Abstraction Purpose Engineering consideration
Device Represents an available supported device or associated processing resource. Verify device capabilities before selecting an execution mechanism.
Memory map Describes memory regions made available to supported operations. Correct permissions, registration and memory lifetime are essential.
Buffer Describes data associated with a memory region and an operation. Buffer boundaries and ownership must remain valid throughout execution.
Context Represents configured execution state for an applicable library. Tasks must follow the supported context state and lifecycle requirements.
Task Describes an operation submitted for processing. Submission success is distinct from successful operation completion.
Progress engine Drives progress and completion handling for applicable contexts. Applications must implement the required progress and callback processing model.
PROGRAMMABLE NETWORK PIPELINES

DOCA Flow: programming hardware packet processing

DOCA Flow provides a programming model for building supported packet processing pipelines in NVIDIA networking hardware.

An application can establish processing pipes, configure matching conditions, install entries, associate supported actions and define forwarding behaviour.

A pipe represents a logical processing structure. Entries establish specific processing conditions within that structure. Multiple pipes can cooperate to implement more complex packet processing behaviour.

DOCA FLOW — MULTISTAGE HARDWARE PIPELINE
INGRESS PACKET HARDWARE PROCESSING DOMAIN ROOT CLASSIFICATION PIPE Protocol / ingress metadata SECURITY POLICY PIPE Match / allow / drop DROP ACTION Policy denies packet MISS ACTION Configured alternative TUNNEL PROCESSING PIPE Supported header operations FORWARDING PIPE CONFIGURED DESTINATION MATCH ALLOW DENY MISS MONITORING Entry counters Processing status Resource utilisation Configured meters
Example logical DOCA Flow pipeline. Actual pipe types, domains, entry priorities, monitoring resources and supported forwarding transitions depend on hardware and SDK capabilities. Animation does not represent measured traffic.
PIPE

Processing pipes

Define logical processing structures with supported match, action and forwarding configurations.

ENTRY

Flow entries

Install specific processing conditions and associated behaviour within a configured pipe.

MATCH

Traffic classification

Identify packets using supported header fields, ingress information and processing metadata.

ACT

Packet actions

Apply supported packet transformations, metadata operations and other hardware processing behaviour.

FWD

Forwarding decisions

Direct traffic toward supported destinations, subsequent pipes, queues or configured drop outcomes.

MON

Monitoring resources

Associate supported counters, meters and other monitoring mechanisms with processing behaviour.

DOCA Flow allows software to establish hardware packet processing behaviour without requiring the infrastructure application itself to execute the complete forwarding decision for every packet.
ACCELERATED DATA MOVEMENT

DOCA DMA: moving data without CPU-driven copying

Infrastructure applications frequently need to move data between memory buffers. Examples include transferring application data, staging infrastructure processing operations and exchanging information between accessible processing domains.

Direct Memory Access allows supported hardware resources to perform memory transfers without requiring the general-purpose CPU to execute every individual copy operation.

DOCA DMA provides a programming model through which applications can submit supported memory transfer operations involving appropriately configured source and destination buffers.

DMA — CONTROL PATH AND DATA MOVEMENT PATH
INFRASTRUCTURE APPLICATION Configure buffers and submit DMA task DOCA DMA CONTEXT DMA EXECUTION ENGINE SOURCE BUFFER DESTINATION BUFFER READ WRITE COMPLETION MEMORY ACCESS / PERMISSIONS / BUFFER LIFETIME
Conceptual DMA transfer. Source and destination memory must be accessible to the selected device through supported memory registration, export, import and permission mechanisms where required.
DMA DOES NOT MEAN UNRESTRICTED MEMORY ACCESS

DMA operations depend on valid memory mappings, device permissions, platform isolation and supported addressing mechanisms. Applications must not assume that a DPU can access arbitrary host or device memory simply because it supports DMA.

The performance benefit of DMA depends on transfer size, submission overhead, queue behaviour, memory locality, PCIe bandwidth and the ability to overlap data movement with other processing.

Small transfers may not always benefit from acceleration once operation setup and completion overhead are considered. Production applications should evaluate batching and asynchronous processing rather than assuming every memory copy should be offloaded.

PROGRAMMABLE ACCELERATOR EXECUTION

The Data Path Accelerator: DPA

BlueField-3 introduces programmable Data Path Accelerator resources designed to support data-path-oriented processing close to the networking hardware.

The DPA provides a different execution environment from the general-purpose Arm processing domain. It is intended for supported operations that benefit from programmable processing associated with networking and data movement.

DOCA DPA provides software mechanisms for developing, loading and managing supported DPA execution. Applications can coordinate DPA processing with other infrastructure resources through the applicable programming model.

BLUEFIELD — HETEROGENEOUS PROCESSING RESOURCES
PROGRAMMABLE INFRASTRUCTURE SILICON
ARM DOMAIN Linux and infrastructure applications
DPA DOMAIN Supported programmable data-path execution
CONNECTX Hardware packet processing
DMA Supported memory transfers
LOGICAL RESOURCE CONNECTIVITY
MEMORY Accessible data and processing state
PCIe Host and supported device connectivity
NETWORK Network interfaces and packet queues
ACCEL Other supported specialised engines
Conceptual heterogeneous processing architecture, not a physical BlueField die layout. Illuminated engines illustrate available processing categories rather than actual resource utilisation.
Execution domain Processing model Typical responsibility
Host CPU General-purpose computing Application workloads and host software.
Embedded Arm cores General-purpose embedded computing Infrastructure applications, Linux services and management logic.
DPA Specialised programmable execution Supported data-path-oriented operations.
ConnectX hardware Hardware packet processing Supported classification, steering, forwarding and packet transformations.
DMA engine Specialised data movement Supported memory transfer operations.
The architectural objective is not to execute every infrastructure function on one processor. It is to place each operation on an appropriate processing resource while coordinating the complete workflow through software.
INFRASTRUCTURE EXECUTION ENVIRONMENT

Embedded Linux and infrastructure applications

In an appropriate DPU-mode deployment, BlueField provides an embedded Linux environment running on its Arm processing resources.

This environment can execute infrastructure applications, management services, networking software and supported DOCA-based applications.

The embedded environment has its own operating system lifecycle, software packages, configuration, management interfaces and operational monitoring requirements.

It should therefore be treated as an infrastructure computing domain rather than simply as an extension of a conventional network adapter.

OS

Operating environment

Embedded Linux provides process execution, memory management, networking and system administration capabilities.

APP

Infrastructure applications

Supported applications implement infrastructure behaviour and coordinate available hardware processing resources.

MGT

Management connectivity

Appropriate management interfaces support provisioning, monitoring, configuration and operational access.

SVC

Service lifecycle

Infrastructure services require controlled startup, shutdown, health monitoring, recovery and software updates.

LOG

Operational telemetry

Application logs, system statistics and hardware evidence help establish whether infrastructure operations are functioning.

FW

Firmware compatibility

Firmware, drivers, operating system packages and DOCA software must form a supported deployment combination.

APPLICATION ENGINEERING

Building a DOCA infrastructure application

A production infrastructure application requires more than a successful API call. It must manage device capabilities, configuration state, hardware resources, operation completion and error recovery.

Consider an application that establishes hardware packet classification and forwarding for an infrastructure network.

01

Discover the execution environment

Identify available devices, supported capabilities, operating mode and applicable software versions.

02

Establish application configuration

Determine the required network ports, processing domains, resource limits and intended infrastructure policy.

03

Initialise supported libraries

Create the required library-specific resources and validate successful initialisation before attempting to program hardware.

04

Create processing structures

Establish the required pipes, matching templates, actions and forwarding behaviour using the supported programming model.

05

Install and verify processing entries

Submit entry creation operations, process required completion mechanisms and verify successful installation.

06

Observe infrastructure behaviour

Inspect counters, application state, error reporting and traffic behaviour to verify the intended processing outcome.

07

Manage updates and recovery

Handle configuration changes, failed operations, resource exhaustion and infrastructure service restarts.

08

Release resources safely

Complete outstanding operations and destroy resources in accordance with the selected library's lifecycle requirements.

DOCA FLOW — CONCEPTUAL APPLICATION LOGIC
// Illustrative pseudocode — not compilable DOCA C

device = discover_supported_device();

verify_capabilities(device);

flow_environment = initialise_flow_resources(device);

port = configure_supported_flow_port(flow_environment);

// Establish the required processing structures

root_pipe = create_classification_pipe(port);

security_pipe = create_policy_pipe(port);

forwarding_pipe = create_forwarding_pipe(port);

// Install example infrastructure behaviour

entry = submit_flow_entry(
    security_pipe,
    match = tenant_policy,
    action = permitted_processing,
    forward = forwarding_pipe
);

// Verify installation before declaring readiness

process_entry_completions();

if (entry_installation_failed) {
    report_error();
    apply_defined_failure_policy();
}

// Observe the installed processing behaviour

while (service_running) {
    inspect_supported_counters();
    reconcile_desired_and_actual_state();
    handle_configuration_changes();
}

// Complete outstanding work and release resources

shutdown_processing_safely();
Educational pseudocode illustrating application structure. Function names are conceptual placeholders, not actual DOCA SDK function signatures. Use the API reference and examples corresponding to the installed SDK release for implementation.
PRODUCTION SOFTWARE ARCHITECTURE

From DOCA libraries to infrastructure services

A DOCA library provides a programming mechanism. An infrastructure service combines programming mechanisms with application logic, configuration, operational management and lifecycle control.

A network infrastructure service, for example, may combine hardware flow programming with policy management, monitoring, management communication and configuration reconciliation.

INFRASTRUCTURE SERVICE COMPOSITION
EXTERNAL INFRASTRUCTURE MANAGEMENT
Desired configuration Policy distribution Health and telemetry
INFRASTRUCTURE SERVICE
Configuration validation Resource management State reconciliation Failure handling Application monitoring Lifecycle management
DOCA AND SUPPORTED DEVICE INTERFACES
Flow programming Data movement Accelerator execution
OBSERVED INFRASTRUCTURE STATE
Installed rules Hardware counters Operation results
Example production service architecture. The infrastructure application must reconcile intended configuration with actual device state. DOCA libraries do not automatically supply every service-management function shown.

This distinction is particularly important in distributed cloud infrastructure. A controller may successfully distribute a configuration while an individual DPU fails to install the corresponding hardware processing state.

Production services therefore require mechanisms to detect incomplete configuration, report operational readiness and recover from inconsistent infrastructure state.

ASYNCHRONOUS INFRASTRUCTURE PROCESSING

Submission, execution and completion

Many accelerated infrastructure operations use asynchronous execution models. An application submits work and later receives evidence that the operation has completed successfully or failed.

Asynchronous execution allows applications to overlap processing operations and avoid waiting synchronously for every individual hardware action.

However, asynchronous execution introduces resource ownership, ordering, completion handling and backpressure requirements.

ASYNCHRONOUS OPERATION TIMELINE
SUBMISSION EXECUTION COMPLETION A B C TASK A EXECUTION TASK B TASK C EXECUTION B COMPLETE A COMPLETE C COMPLETE CONCEPTUAL TIME — NOT MEASURED LATENCY
Illustrative asynchronous execution. Completion ordering depends on the specific library, context, queue and operation guarantees. Applications must follow documented ordering requirements rather than assuming submission order always determines completion order.

Operation concurrency

Multiple supported operations may be outstanding concurrently, subject to library and resource constraints.

Resource ownership

Memory, buffers and task resources must remain valid until the applicable completion and ownership requirements are satisfied.

Backpressure

Applications must handle unavailable resources, full queues and submission failures without uncontrolled growth in outstanding work.

PRODUCTION TROUBLESHOOTING

Investigating DOCA and BlueField software failures

Troubleshooting a DOCA-based infrastructure application requires examining multiple layers. A failure may originate in application configuration, device capabilities, resource allocation, firmware, memory permissions or hardware processing state.

The investigation should begin by establishing the actual execution environment and confirming that the required software and device resources are available.

BLUEFIELD LINUX — READ-ONLY INVESTIGATION
# Identify the operating system
cat /etc/os-release

# Identify kernel and processor architecture
uname -a
uname -m

# Inspect available PCI devices
lspci -nn

# Inspect installed DOCA packages on Debian-based systems
dpkg-query -W 'doca*'

# Inspect device and port relationships
devlink dev show
devlink port show

# Inspect available device information
devlink dev info

# Inspect network interfaces and counters
ip -br link
ip -s link

# Inspect processor and memory utilisation
top
free -h

# Inspect failed systemd services
systemctl --failed

# Inspect application-specific service logs
journalctl -u SERVICE_NAME --since "1 hour ago"

# Inspect recent kernel messages
journalctl -k --since "1 hour ago"
Example Linux inspection commands. Replace SERVICE_NAME with the actual service identifier. Command availability and required privileges depend on the operating system, deployment and installed packages. These commands are not a substitute for library-specific diagnostics.
Observed symptom Possible cause Evidence to investigate
Application fails to initialise Incompatible software, unavailable device or invalid configuration. Application logs, installed packages, device discovery and capability checks.
Flow entry installation fails Unsupported match/action combination or insufficient hardware resources. Entry completion status, pipe configuration and device resource information.
Installed flow receives no traffic Incorrect ingress mapping, match fields or processing pipeline ordering. Flow counters, port mapping, packet headers and forwarding configuration.
DMA task fails Invalid buffer boundaries, permissions or memory registration. Task error status, memory map configuration and buffer lifetime.
Operations do not complete Incorrect progress handling, resource pressure or execution failure. Context state, progress engine activity, outstanding tasks and error callbacks.
DPA application fails to start Unsupported execution environment, application build or resource configuration. Device capability checks, application loading status and DPA-specific diagnostics.
Infrastructure service repeatedly restarts Invalid configuration, missing dependencies or application failure. Service logs, dependency state, process exit status and resource utilisation.
Performance below expectations Submission overhead, software processing, queue pressure or memory bottlenecks. Operation latency, queue occupancy, CPU profiling and hardware counters.
SUCCESSFUL INITIALISATION IS NOT PRODUCTION READINESS

An application can initialise successfully while individual hardware rules fail to install or submitted operations fail during execution. Production readiness must be based on verified processing state, successful operation completion and observed infrastructure behaviour.

INFRASTRUCTURE LIFECYCLE ENGINEERING

Managing software, firmware and API compatibility

BlueField infrastructure introduces an additional software and firmware lifecycle into the data centre. Engineers must manage the relationship between host software, embedded operating system components, device firmware and DOCA applications.

An infrastructure application developed against one SDK release may require changes before it can be rebuilt or deployed against another release.

Hardware generation

Confirm that the required processing resources and acceleration capabilities exist on the selected BlueField generation.

Firmware compatibility

Validate that the installed firmware supports the required software stack and processing operations.

Driver compatibility

Ensure host and embedded device drivers meet the requirements of the selected deployment.

SDK compatibility

Build and test applications using the intended SDK headers, libraries and documented programming interfaces.

Upgrade sequencing

Plan service interruption, configuration preservation, compatibility validation and supported upgrade procedures.

Recovery planning

Maintain tested recovery procedures for failed application deployments, incompatible configurations and interrupted upgrades.

ENGINEERING TAKEAWAY

DOCA as the programmable infrastructure layer

NVIDIA DOCA enables developers to build infrastructure applications that coordinate programmable software and specialised networking hardware.

DOCA Core provides common abstractions for applicable device, memory and execution resources. DOCA Flow exposes supported hardware packet processing mechanisms. DOCA DMA provides accelerated data movement capabilities, while DOCA DPA supports programmable execution on compatible accelerator resources.

These programming mechanisms allow infrastructure developers to select appropriate execution resources rather than treating the host CPU as the default location for every infrastructure operation.

Effective DOCA engineering requires careful attention to resource lifecycles, device capabilities, asynchronous operation completion, software compatibility and operational evidence.

The real architectural value of DOCA is the ability to translate infrastructure intent into coordinated software and hardware execution, while retaining control over processing state, resource ownership and operational behaviour.
NETWORK INSIGHT — ENGINEERING GUIDES BLUEFIELD DPU / SECTION 04
Network Insight / Interactive Engineering 04

Programming the DPU
From Software to Silicon

Build a conceptual DOCA Flow application, initialise infrastructure resources, create programmable flow pipes and observe how software configuration becomes accelerated packet-processing behaviour.

SILICON OFFLOAD EDITION DOCA SOFTWARE ARCHITECTURE PROGRAMMABLE FLOW PIPES APPLICATION DEPLOYMENT LAB
01 / Software ecosystem

Explore the DOCA programming environment

02 / Application builder

Configure your infrastructure application

03 / Software-to-silicon architecture
DEVELOPMENT READY
BLUEFIELD / PROGRAMMABLE INFRASTRUCTURE APPLICATION / CONTROL PLANE ACCELERATED NETWORK DATA PLANE INFRASTRUCTURE APPLICATION Firewall application DOCA FLOW INITIALISATION Configuration / resources / queues DEVICE AND PORT CONTEXT Accessible networking resources DPU ARM DOMAIN Example execution location CONFIGURATION AND POLICY RESOURCE MANAGEMENT SOFTWARE-TO-HARDWARE PROGRAMMING LOGICAL FLOW PIPE Basic match-action pipe FLOW ENTRIES No installed entries INGRESS Network packet EGRESS Forwarded packet Miss / drop / software exception Conceptual software and hardware relationships
Configure the application and begin deployment.
Installed entries
0
HW forwarded
0
SW exceptions
0
Dropped
0
04 / Application source editor

Translate configuration into programming logic

bluefield_flow_demo.pseudo.c EDUCATIONAL PSEUDOCODE


    

This is illustrative programming logic, not compilable DOCA source code.

05 / Hardware resource allocation

Observe resource consumption

A shared simulated resource pool is used to demonstrate allocation failures and deployment planning.

Flow entry resources 0 / 64
Application allocation 0 entries
Simulated counter resources 0 / 64
Resource availability will be evaluated during deployment.
Engineering distinction

Creating a flow pipe does not automatically mean every entry has been successfully programmed into hardware. Applications must verify entry processing and completion status.

Resource units are fictional teaching values. They are not BlueField-3 hardware capacity limits.

06 / Runtime programming state

Inspect the installed application

PIPE MATCH TEMPLATE ACTION ENTRY UNITS STATE HITS
No application is currently installed.
07 / Application validation

Inject traffic into the programmed data plane

Deploy an application before testing traffic.

Test packets are evaluated against the installed configuration, not unsaved changes in the application builder.

08 / Application event console

Investigate deployment evidence

Educational diagnostic messages. These are not actual DOCA SDK logs or firmware error codes.

09 / Production engineering challenge

The infrastructure application that will not deploy

A multi-tenant server requires an accelerated firewall application. HTTPS traffic must be forwarded, while unmatched traffic must be dropped.

The application fails because its requested flow entries exceed the available simulated hardware resources. Investigate the resource pool, correct the allocation and redeploy.

Preserve the existing resource reservation and total capacity. Install at least 16 entry units, enable counters and validate HTTPS forwarding and SSH rejection.

Load the incident to begin your investigation.
10 / Engineering interpretation

Understanding programmable infrastructure

Application execution

Depending on the application and deployment model, DOCA software can execute on supported host or DPU environments. The diagram uses embedded DPU execution as an example.

Software control plane

Infrastructure applications configure devices, ports, flow pipes, match criteria, actions and associated resources.

Hardware data plane

Once eligible entries are installed, matching packets can be processed by accelerated networking hardware without requiring per-packet application execution.

Programming completion

Production applications must check resource availability, asynchronous entry completion, supported actions and error handling before assuming that offload works.

This laboratory models selected DOCA Flow concepts rather than implementing the DOCA SDK. The basic and control pipe choices use simplified logical behaviour. Actual pipe types have different matching, action and forwarding constraints.

The generated pseudocode intentionally uses fictional helper functions. It is not a version-specific API reference. Resource allocations, deployment timing and diagnostic messages are simulated.

NVIDIA DOCA Technical Documentation
NETWORK INSIGHT
Engineering Guide 06 / Silicon Offload Edition
NETWORK INSIGHT
NVIDIA BlueField DPU Architecture
SILICON OFFLOAD EDITION
SECTION 05 / INFRASTRUCTURE SECURITY

Moving Security Beyond the Host Zero Trust and Infrastructure Security

Engineering independent infrastructure enforcement domains using BlueField DPUs, distributed security policies, hardware-accelerated packet inspection, protected management environments and cryptographic processing.

BLUEFIELD — INDEPENDENT SECURITY DOMAIN
BlueField infrastructure security architecture Host workloads are separated from a DPU infrastructure security domain. An independent management environment distributes policy. Eligible network traffic passes through configured security enforcement resources before reaching the data centre network. HOST WORKLOAD DOMAIN APPLICATION A APPLICATION B COMPROMISED HOST Application workload Application workload Untrusted traffic attempt HOST OS / HYPERVISOR / VIRTUAL NETWORK INTERFACES SECURITY CONTROLLER Identity / policy / management Protected administrative access CONFIGURED INFRASTRUCTURE TRUST BOUNDARY BLUEFIELD INFRASTRUCTURE SECURITY DOMAIN ARM SOFTWARE / SECURITY POLICY AGENT Policy validation / configuration / reconciliation / telemetry CONFIGURED HARDWARE SECURITY ENFORCEMENT CLASSIFICATION POLICY MATCH CRYPTO OFFLOAD FORWARDING Ingress metadata Allow / deny Supported IPsec Eligible traffic POLICY DROP COUNTERS / EVIDENCE DATA CENTRE NETWORK FABRIC
Permitted traffic Denied traffic Protected policy control Workload and fabric connectivity
Conceptual DPU-mode security architecture. Enforcement depends on the configured operating mode, traffic steering, management isolation, installed security software and supported hardware capabilities. The diagram is not a literal silicon floorplan or a guarantee of complete host isolation.
SECURITY ARCHITECTURE

Why infrastructure security is moving beyond the host

Traditional data centre security architectures frequently depend on software executing within the same general-purpose computing environment as application workloads.

Host operating systems, hypervisors, virtual switches, software firewalls and infrastructure agents can all participate in network security enforcement.

This architecture can provide effective security, but it creates dependencies between the workload environment and the infrastructure components responsible for protecting that environment.

If a sufficiently privileged attacker compromises the host, security mechanisms under that host's administrative control may also become vulnerable to modification, disabling or circumvention.

A DPU-based architecture can move selected infrastructure security functions into a separate processing and administrative domain, reducing dependence on host-controlled enforcement.

The architectural objective is to prevent the workload being protected from automatically controlling the infrastructure security mechanisms responsible for protecting it.
TRUST

Independent trust boundaries

Separate infrastructure administration and security enforcement from ordinary workload execution wherever the deployment permits.

POLICY

Distributed enforcement

Apply supported security policies close to workload network attachment points instead of relying exclusively on central firewalls.

ACCEL

Hardware acceleration

Execute eligible classification, filtering and cryptographic operations using supported specialised processing resources.

TRUST DOMAIN COMPARISON

Host-controlled security versus DPU-controlled security

The important distinction between these models is not simply where packet processing occurs. It is which administrative domain controls the enforcement mechanisms.

HOST-CONTROLLED ENFORCEMENT
Application workloads
Host operating system Shared administrative dependency
Host-managed virtual switch
Host-managed security policy Potentially affected by host compromise
Network adapter and fabric

Security may be weakened if a privileged compromise provides control over the host's enforcement software. Actual exposure depends on the host and hypervisor isolation model.

DPU-CONTROLLED ENFORCEMENT
Application workloads
Host operating system
INFRASTRUCTURE TRUST BOUNDARY
Protected DPU management domain Independent policy administration
Configured DPU security enforcement Supported hardware and software processing
Network fabric

Properly configured DPU infrastructure can preserve selected network security controls independently of the host operating system.

PHYSICAL SEPARATION DOES NOT AUTOMATICALLY ESTABLISH TRUST

A separate processor is not sufficient by itself. Management permissions, firmware integrity, device ownership, PCIe access, reset controls, traffic steering and alternative network paths must also be considered.

ZERO TRUST ENGINEERING

BlueField within a Zero Trust architecture

Zero Trust is a security architecture in which access is not granted solely because a workload, user or device resides inside a particular network boundary.

Access decisions should consider authenticated identities, resource requirements, policy, environmental context and applicable security evidence.

BlueField can participate in this architecture by providing distributed infrastructure policy enforcement. However, the DPU does not replace the identity systems, policy decision mechanisms or application authorisation controls required by a complete Zero Trust deployment.

ZERO TRUST — POLICY DECISION AND ENFORCEMENT
01
IDENTITY Authenticate workload or device identity
02
POLICY DECISION Evaluate identity, context and access requirements
03
DPU ENFORCEMENT Apply translated and supported network policy
04
OBSERVATION Collect evidence and reassess access decisions
Logical Zero Trust workflow. Identity verification and policy decisions may be performed by external systems. DPU hardware enforces supported network representations of the resulting policy.

Explicit verification

Establish identity and relevant security context before granting access to protected infrastructure resources.

Least privilege

Permit only the communications and operations required by the workload's intended function.

Assume breach

Design enforcement boundaries to limit the consequences of a compromised workload or infrastructure component.

Continuous evaluation

Reassess access when identity, configuration, security posture or policy changes.

Policy consistency

Verify that distributed enforcement points implement the intended policy version.

Independent evidence

Collect enforcement telemetry from infrastructure resources outside the ordinary workload domain.

HARDWARE SECURITY ARCHITECTURE

Security processing within the BlueField DPU

BlueField combines general-purpose infrastructure processing with specialised networking and acceleration capabilities.

Security applications executing in the embedded software environment can configure supported hardware processing behaviour, allowing eligible operations to execute without requiring a general-purpose processor to inspect and process every packet individually.

BLUEFIELD — SECURITY PROCESSING RESOURCES
INFRASTRUCTURE SECURITY SILICON
ARM DOMAIN Security agents and infrastructure services
FLOW STEERING Supported traffic classification and actions
CRYPTO Supported cryptographic acceleration
DPA Supported programmable data-path execution
LOGICAL SECURITY RESOURCE CONNECTIVITY
FIRMWARE Device integrity and supported boot mechanisms
MANAGEMENT Protected infrastructure configuration
MEMORY ACCESS Supported DMA and access isolation mechanisms
TELEMETRY Supported counters and processing evidence
Conceptual grouping of BlueField security-related processing resources. Not a physical die layout. Some security functions are implemented through software and platform configuration rather than dedicated hardware engines.
DISTRIBUTED NETWORK SECURITY

Hardware-accelerated distributed firewalls

A distributed firewall places security enforcement close to individual workloads or infrastructure attachment points.

Instead of requiring all traffic to traverse a central firewall appliance, distributed enforcement can apply policy at multiple servers throughout the data centre.

BlueField-based infrastructure can implement supported firewall processing using a combination of embedded software, hardware flow steering and appropriate security applications.

DISTRIBUTED FIREWALL — EAST-WEST ENFORCEMENT
CENTRAL POLICY CONTROLLER SPINE 01 SPINE 02 LEAF 01 LEAF 02 LEAF 03 BLUEFIELD DPU BLUEFIELD DPU BLUEFIELD DPU Security enforcement Security enforcement Security enforcement WEB TIER APPLICATION TIER UNAUTHORISED WORKLOAD Tenant A Tenant A Tenant B DENIED AT SOURCE AUTHORISED EAST-WEST COMMUNICATION
Example distributed firewall deployment with source-side enforcement. Actual traffic paths, enforcement locations and hardware offload depend on the network design and installed security implementation.

Distributed enforcement is particularly valuable for east-west traffic, where applications communicate with other applications within the data centre.

Traffic can be evaluated at the source, destination or both, depending on the architecture. This reduces the need to redirect every internal communication through a central inspection point.

HARDWARE FIREWALLING HAS CAPABILITY LIMITS

Hardware-supported packet matching and actions should not be confused with unrestricted application-layer inspection. Stateful inspection, connection tracking, application identification and deep packet inspection depend on the available hardware and security software.

WORKLOAD ISOLATION

Microsegmentation and least-privilege communication

Microsegmentation divides infrastructure into smaller security domains and controls the communications permitted between them.

Rather than treating an entire subnet or virtual network as a single trusted environment, microsegmentation can enforce more granular workload communication requirements.

Consider a three-tier enterprise application consisting of a web tier, application tier and database tier. The web tier should communicate with the application tier, while the application tier requires access to the database.

Direct access from the web tier to the database may not be necessary and can therefore be denied.

MICROSEGMENTATION — EXAMPLE POLICY MATRIX
SOURCE / DEST.
WEB
APP
DATABASE
MANAGEMENT
WEB
N/A
ALLOW TCP 8443
DENY
DENY
APP
DENY NEW
N/A
ALLOW TCP 5432
DENY
DATABASE
DENY NEW
DENY NEW
N/A
DENY
MANAGEMENT
ADMIN POLICY
ADMIN POLICY
ADMIN POLICY
N/A
Illustrative policy for newly initiated connections. Return traffic requires an appropriate stateful mechanism or explicit reverse-direction rules. Management access requires separate authentication and authorisation. Example ports are not universal application requirements.

A DPU security application can translate applicable network policy into supported matching and forwarding behaviour. This may involve tenant identifiers, virtual port metadata, network addresses, protocol information and transport ports.

The challenge is ensuring that these network attributes remain correctly associated with authenticated workload identities.

A hardware flow rule matching an IP address is not, by itself, an authenticated workload identity. Zero Trust requires a reliable relationship between identity, policy and the network attributes used for enforcement.
CRYPTOGRAPHIC ACCELERATION

IPsec offloading and protected infrastructure traffic

Encryption protects data confidentiality and, when appropriate authenticated encryption mechanisms are used, provides integrity and authenticity protection for transmitted data.

IPsec can introduce substantial processing requirements in high-throughput infrastructure. Cryptographic operations, packet encapsulation and security association processing consume computing resources.

Supported BlueField networking hardware can accelerate eligible IPsec operations, reducing the amount of cryptographic processing performed by general-purpose processors.

IPSEC ESP — CONCEPTUAL TUNNEL MODE TRANSFORMATION
ORIGINAL IP PACKET
INNER IP
TCP / UDP
APPLICATION DATA
BLUEFIELD CRYPTOGRAPHIC PROCESSING Configured security association and supported ESP operations
PROTECTED ESP PACKET
OUTER IP
ESP HEADER
IV*
ENCRYPTED INNER PACKET + ESP TRAILER
AUTH TAG*
Simplified ESP tunnel-mode example using an authenticated encryption configuration. Field sizes are not proportional. IV and authentication-tag details depend on the selected algorithm. Hardware offload capabilities and supported encapsulations vary.
SA

Security associations

Define applicable cryptographic parameters, keys, identifiers and processing state for protected traffic.

ESP

Packet protection

Apply supported encryption, authentication and encapsulation operations according to the selected IPsec configuration.

KEY

Key management

Establish, distribute, rotate and protect cryptographic keys using appropriate management and key-exchange mechanisms.

SEQ

Replay protection

Maintain the required sequence-number and anti-replay processing state for the selected security association.

MTU

Encapsulation overhead

Account for additional headers and trailers when engineering path MTU, packet sizing and network throughput.

OFF

Offload verification

Confirm which operations are actually accelerated and which remain in the software processing path.

CRYPTOGRAPHIC OFFLOAD IS NOT KEY MANAGEMENT

Accelerating encryption does not automatically establish secure key distribution, peer authentication or security association lifecycle management. These responsibilities must be implemented by the complete security architecture.

PLATFORM INTEGRITY

Secure boot, roots of trust and infrastructure attestation

Moving security enforcement into a separate infrastructure processing domain introduces an important question: how can the infrastructure establish confidence in the integrity of that domain?

Secure boot mechanisms can verify authorised software or firmware components during the platform startup process, depending on the device configuration and supported chain of trust.

A hardware-backed root of trust can provide a foundational security mechanism from which subsequent verification operations are established.

CONCEPTUAL PLATFORM BOOT TRUST CHAIN
RT
ROOT OF TRUST Foundational platform trust mechanism
FW
FIRMWARE Verify applicable signed components
OS
BOOT SOFTWARE Continue configured verification chain
APP
INFRASTRUCTURE Start approved services under platform policy
Conceptual trust chain. Actual BlueField boot stages, verification keys, firmware policies and application integrity mechanisms depend on the hardware generation and provisioning configuration. Secure boot alone does not authenticate every runtime application.

Secure boot versus measured boot

Secure boot is primarily concerned with enforcing a configured verification policy during startup. Measured boot records measurements of applicable components so that platform state can be evaluated using those measurements.

These mechanisms are complementary but distinct. A verified boot process does not automatically provide remote attestation evidence, and measured boot does not necessarily prevent an unauthorised component from executing.

Mechanism Primary purpose Engineering consideration
Root of trust Establish a foundational platform security mechanism. Verify provisioning, ownership and applicable key protection.
Secure boot Enforce verification of applicable boot components. Confirm that the required verification policy is enabled and correctly provisioned.
Measured boot Record applicable platform component measurements. Measurements require interpretation against trusted reference values.
Remote attestation Provide evidence of applicable platform state to an external verifier. Validate evidence authenticity, freshness and policy compliance.
Runtime protection Protect infrastructure after startup. Secure boot does not eliminate runtime vulnerabilities or configuration errors.

Attestation within infrastructure access decisions

Where supported attestation mechanisms are available, an external verifier can evaluate platform evidence against an established security policy.

The resulting trust decision may influence whether the infrastructure is permitted to receive sensitive configuration, establish protected communications or participate in particular workload environments.

ATTESTATION IS A POLICY INPUT, NOT A PERMANENT GUARANTEE

Attestation evidence describes applicable measured platform properties. Its security value depends on evidence freshness, trusted reference measurements, verifier integrity and the scope of the measurements collected.

MEMORY AND DEVICE SECURITY

PCIe, DMA protection and infrastructure isolation

BlueField communicates with host infrastructure through PCIe and supported device interfaces. These interfaces provide essential connectivity but also introduce security boundaries that must be engineered carefully.

Direct Memory Access allows devices to perform supported memory operations without requiring the host CPU to execute every individual transfer.

However, unrestricted device access to memory would undermine isolation between workloads, devices and infrastructure processing domains.

DMA — CONCEPTUAL HOST MEMORY ACCESS CONTROL
BLUEFIELD DEVICE DMA REQUEST Device-visible address HOST IOMMU DEVICE / DOMAIN ASSOCIATION ADDRESS TRANSLATION ACCESS PERMISSIONS HOST PHYSICAL MEMORY AUTHORISED BUFFER Mapped and permitted PROTECTED MEMORY Access not authorised OTHER WORKLOAD Separate memory ownership TRANSLATE AND AUTHORISE Access governed by configured platform permissions
Simplified host IOMMU-mediated DMA model. Actual address translation, device isolation, peer-to-peer access and memory protection depend on platform configuration and supported hardware mechanisms. DPU-local memory protection is a separate architectural consideration.

IOMMU protection

Restrict applicable device DMA operations through configured address translation and memory access permissions.

Memory registration

Establish valid memory regions and permissions for supported accelerated operations.

Device ownership

Control which administrative domain can configure physical and virtual device functions.

Virtual function isolation

Configure appropriate separation between SR-IOV functions, tenants and associated infrastructure resources.

Reset and lifecycle controls

Evaluate which components can reset or reconfigure devices and how these actions affect security enforcement.

Alternative data paths

Identify peer-to-peer, local switching and alternative interface paths that may require separate enforcement mechanisms.

DEVICE ADMINISTRATION

BlueField operating modes and security ownership

BlueField operating modes influence the relationship between host software, embedded infrastructure software and networking resources.

In a suitable DPU-mode configuration, embedded infrastructure software can control selected networking and infrastructure functions. Supported restricted configurations can further limit host administrative access to applicable device resources.

NIC-mode operation provides a different ownership and execution model and should not be assumed to offer the same independent infrastructure enforcement properties.

Configuration Architectural characteristic Security implication
NIC mode Networking-oriented device operation with a different embedded processing model. Do not assume independent DPU security enforcement is available.
DPU mode Embedded infrastructure processing and applicable device control. Enables supported infrastructure services outside ordinary host execution.
Restricted host access Supported restrictions on selected host administrative capabilities. Can strengthen separation between host and infrastructure administration.
VERIFY THE ACTUAL BLUEFIELD CONFIGURATION

Operating-mode terminology, restricted-access mechanisms and supported management controls vary across BlueField generations and software releases. Consult the documentation for the installed device before making security assumptions or changing its operating mode.

DISTRIBUTED POLICY ENGINEERING

Security policy installation and verification

Distributed security architectures must maintain consistency between intended security policy and the actual enforcement state installed across infrastructure devices.

A successful policy distribution operation does not necessarily mean that every DPU has successfully programmed its corresponding hardware processing resources.

01

Establish workload identity

Associate the workload with trusted identity information and appropriate infrastructure attachment metadata.

02

Evaluate the intended access policy

Determine which communications should be permitted, denied or subjected to additional processing.

03

Translate policy into enforcement behaviour

Convert applicable policy requirements into supported network matches, actions, forwarding and software processing.

04

Distribute authenticated configuration

Deliver versioned configuration through protected infrastructure management mechanisms.

05

Install and validate processing state

Confirm that required rules and resources have been successfully installed rather than relying only on controller acknowledgement.

06

Verify observed traffic behaviour

Test authorised and unauthorised communication paths and correlate outcomes with enforcement counters and application evidence.

07

Reconcile and maintain policy

Detect configuration drift, failed updates, resource exhaustion and changes in workload identity or infrastructure state.

Security policy is not fully deployed when the controller has sent it. It is deployed when the required enforcement points have installed it and the resulting traffic behaviour has been independently verified.
SECURITY RESILIENCE

Fail-open, fail-closed and last-known-good policy

Infrastructure security services must define how enforcement behaves when a controller, management connection, security application or hardware processing resource becomes unavailable.

Without explicit failure behaviour, an infrastructure fault can unexpectedly create either a security exposure or a widespread application outage.

OPEN

Fail-open

Permit applicable traffic when an enforcement dependency fails. This can preserve connectivity but may expose resources to traffic that would normally be denied.

CLOSED

Fail-closed

Deny applicable traffic when required security enforcement cannot be established. This protects the intended boundary but may interrupt legitimate applications.

LKG

Last-known-good policy

Continue enforcing previously validated policy where supported, subject to configuration expiry, resource state and the specific failure condition.

FAILURE BEHAVIOUR MUST BE TESTED

These are architectural strategies rather than universal BlueField operating behaviours. A DPU reset, controller outage, application crash and hardware rule installation failure may produce different outcomes. Each relevant condition requires explicit validation.

INFRASTRUCTURE SECURITY INVESTIGATION

Investigating a suspected host compromise

Consider a workload that begins attempting unauthorised connections to other application tiers after a suspected compromise.

A properly configured DPU enforcement architecture may continue applying network policy independently of the compromised host. Engineers must establish whether this enforcement is actually functioning and determine the scope of the incident.

INCIDENT EVIDENCE — ILLUSTRATIVE SECURITY TELEMETRY
HIGH MEDIUM LOW BASELINE DETECTION POLICY ENFORCEMENT CONTAINMENT VALIDATION Unauthorised attempts Policy drops Legitimate traffic
Synthetic incident illustration, not captured BlueField telemetry or measured performance. The example assumes relevant policy is installed and enforcement remains available during the incident.

The investigation should correlate host evidence with infrastructure-side observations. Relevant evidence may include installed policy versions, hardware rule counters, interface mappings, security application logs and network captures.

A policy drop counter can demonstrate that particular traffic matched a configured drop operation, but it does not prove that every possible communication path has been secured.

BLUEFIELD — READ-ONLY SECURITY INVESTIGATION
# Inspect device and firmware information
devlink dev show
devlink dev info

# Identify network port relationships
devlink port show
ip -br link

# Inspect interface statistics
ip -s link

# Inspect traffic-control rules where applicable
tc -s filter show dev INTERFACE ingress
tc -s filter show dev INTERFACE egress

# Inspect configured IPsec policy and counters
ip xfrm policy
ip -s xfrm state list nokeys

# Inspect IOMMU-related kernel evidence
journalctl -k | grep -Ei 'iommu|dmar|smmu'

# Inspect security service status
systemctl status SECURITY_SERVICE

# Inspect recent security service events
journalctl -u SECURITY_SERVICE --since "1 hour ago"

# Inspect failed infrastructure services
systemctl --failed

# Inspect supported interface-specific statistics
ethtool -S INTERFACE
Example inspection commands for applicable Linux environments. Replace INTERFACE and SECURITY_SERVICE with deployment-specific identifiers. Some commands require elevated privileges. The IPsec state example requests key suppression; other diagnostic output may still contain sensitive infrastructure details. DOCA Flow rules are not necessarily visible through Linux traffic-control inspection.
PRODUCTION TROUBLESHOOTING

Diagnosing DPU security enforcement failures

Observed symptom Possible cause Evidence to investigate
Unauthorised traffic is permitted Missing policy, incorrect rule priority, stale identity mapping or alternative forwarding path. Installed rules, policy version, interface mapping and actual packet journey.
Legitimate application traffic is denied Incorrect policy match, missing return path permission or stale workload metadata. Drop counters, connection state, packet headers and intended policy.
Policy installation fails Unsupported match/action combination, resource exhaustion or software incompatibility. Application logs, rule installation status and device resource information.
IPsec traffic fails Security association mismatch, expired keys, replay processing or encapsulation problems. Key-suppressed SA diagnostics, policy state, counters and path MTU.
Encryption performance is unexpectedly low Software fallback, unsupported offload configuration or resource bottlenecks. Hardware offload status, CPU utilisation, throughput and device statistics.
Host can modify protected configuration Incorrect operating mode or insufficient administrative restrictions. Device ownership, host permissions and management configuration.
Attestation evidence is rejected Unexpected measurements, stale evidence, verifier policy or certificate issues. Applicable attestation evidence, reference values and verifier logs.
DMA operations fail Invalid mappings, permission violations or unsupported memory access. IOMMU evidence, memory registration, device ownership and operation status.
Security changes after a DPU restart Missing policy persistence, incomplete reconciliation or service startup failure. Startup logs, installed policy version and post-restart connectivity tests.
DEFENCE IN DEPTH

What a DPU security architecture does not solve

A DPU provides additional infrastructure enforcement and isolation opportunities, but it does not eliminate the need for other security mechanisms.

Security responsibilities remain distributed across applications, identity systems, operating systems, management environments, network infrastructure and hardware platforms.

Application vulnerabilities

Permitted network connections can still carry requests that exploit vulnerabilities in application software.

Identity compromise

Stolen credentials and incorrectly granted privileges require identity and application security controls.

Local workload communication

Traffic that never traverses a DPU-controlled enforcement path requires appropriate local isolation mechanisms.

DPU software vulnerabilities

Embedded operating systems, firmware and security applications introduce their own attack surfaces and patching requirements.

Management compromise

Compromise of a trusted security controller may allow malicious policy distribution across multiple enforcement points.

Availability attacks

Resource exhaustion, hardware failure and infrastructure disruption can still affect security service availability.

ENGINEERING TAKEAWAY

BlueField as an infrastructure security enforcement platform

NVIDIA BlueField can provide a separate infrastructure processing domain in which selected security functions are implemented independently of ordinary host workloads.

Distributed firewalling and microsegmentation can bring network security enforcement closer to workload attachment points. Supported cryptographic acceleration can reduce the processing burden associated with protected infrastructure communications.

Secure boot, applicable attestation mechanisms, protected management interfaces and appropriate memory access controls can contribute to confidence in the infrastructure security domain.

These capabilities must be combined with authenticated identities, least-privilege policy, validated traffic steering, operational telemetry and carefully engineered failure behaviour.

BlueField does not make a data centre Zero Trust simply by being installed. Its architectural value is providing an additional, independently managed infrastructure enforcement domain that can help implement and verify a broader Zero Trust design.
NETWORK INSIGHT — ENGINEERING GUIDES BLUEFIELD DPU / SECTION 05
Network Insight / Interactive Engineering 05

When the Host Can No Longer Be Trusted

Investigate a compromised data centre server. Explore how independently managed DPU security services can enforce infrastructure policy, contain lateral movement and protect network trust boundaries outside the host operating system.

SILICON SECURITY FORTRESS ZERO TRUST ARCHITECTURE HOST ISOLATION DISTRIBUTED FIREWALL INCIDENT INVESTIGATION
01 / Security investigation scenarios

Choose your infrastructure environment

02 / Security control centre

Configure infrastructure trust

03 / Infrastructure security architecture
TRUST BOUNDARY ACTIVE
DATA CENTRE SERVER / SECURITY CUTAWAY HOST COMPUTE DOMAIN TENANT A Application workload HOST CPU Operating system HOST FIREWALL Policy enabled HOST TRUST STATE: NORMAL PCIe / HOST-DPU INTERFACE BLUEFIELD / INDEPENDENT INFRASTRUCTURE DOMAIN ARM DOMAIN Security services DPU FIREWALL Match / policy CRYPTO IPsec engine CONNECTX Network data plane INDEPENDENT SECURITY MANAGEMENT DATA CENTRE NETWORK FABRIC TENANT A SERVICE Authorised application TENANT B Separate trust domain REMOTE SITE Protected communication Conceptual trust and enforcement architecture
Select a traffic profile and run a security test.
Allowed
0
Blocked
0
Policy violations
0
HW encrypted
0
04 / Traffic investigation

Test communication across trust boundaries

Awaiting security inspection.

Tenant identity in this model is associated with trusted infrastructure attachment metadata, rather than relying solely on a packet's self-declared source address.

05 / Security investigation console

Observe evidence from enforcement decisions

Events are generated by the educational security model. They are not actual BlueField firmware logs or DOCA diagnostic messages.

06 / Infrastructure policy evidence

Inspect security rules and enforcement counters

RULE SECURITY CONDITION INTENDED ACTION ENFORCEMENT HOST HITS DPU HITS
Security engineering distinction

A configured rule is not evidence of effective enforcement. The policy must be installed in the correct processing path, protected against unauthorised modification and independently validated with representative traffic.

07 / Protected packet transformation

Observe the IPsec trust boundary

Original application packet
INNER IPv4 TCP / UDP APPLICATION DATA

Original traffic is inspected against infrastructure policy before entering the modelled protected egress path.

Conceptual tunnel-mode ESP output
OUTER IPv4 ESP HEADER ENCRYPTED INNER PACKET AUTHENTICATION TAG

IPsec output depends on policy, security association state and supported offload.

Transmit remote-site traffic to inspect the resulting protection state.

This is a simplified ESP tunnel-mode illustration using authenticated encryption. Actual packet fields, overhead and offload capabilities depend on the IPsec configuration and supported hardware.

08 / Comparative security experiment

What changes when the host is compromised?

Run the same six traffic profiles through two conceptual architectures with identical security policies but different enforcement locations.

Architecture A

Host-based security

Not tested

Security controls depend on the host operating system.

Architecture B

Independent DPU security

Not tested

Infrastructure enforcement remains outside the compromised host domain under the experiment's assumptions.

The comparison uses fixed experimental configurations and does not modify the active laboratory.
09 / Production security incident

Incident 005 — The compromised tenant server

A tenant application server has suffered a host compromise. Its host firewall has been tampered with, and the infrastructure team has identified unauthorised cross-tenant communication.

Restore infrastructure-level containment without assuming that the host operating system has recovered. Preserve authorised application connectivity and protect remote-site traffic.

○ Establish independently protected DPU enforcement.
○ Verify authorised HTTPS connectivity.
○ Verify unauthorised management access is blocked.
○ Verify cross-tenant lateral movement is blocked.
○ Verify spoofed tenant identity is rejected.
○ Verify remote traffic is hardware encrypted.
○ Verify unmatched traffic is denied.
Load the incident to begin your investigation.
10 / Engineering interpretation

Moving infrastructure security beyond the host

Independent trust domain

BlueField can support infrastructure services running separately from host workloads. The effectiveness of this separation depends on the operating mode, management architecture and protection of privileged interfaces.

Distributed security enforcement

Eligible network security rules can be enforced in accelerated networking hardware, reducing dependence on host-based per-packet processing.

Microsegmentation

Infrastructure policy can restrict communication between workloads and tenants. Trusted workload identity and attachment metadata are important inputs to those decisions.

Cryptographic acceleration

Supported IPsec operations can be accelerated in hardware when the security association, algorithms, software and device configuration permit offloading.

Residual security risk

DPU network enforcement cannot repair a compromised host or automatically prevent local data theft, malicious use of permitted application flows, or every possible infrastructure attack.

Management plane protection

Independent administration, secure boot, firmware integrity, restricted privileges, monitoring and appropriate device configuration remain essential to the infrastructure trust model.

This laboratory is a conceptual security model, using BlueField-3 as its architectural reference. It assumes that all tested network traffic traverses the illustrated enforcement path. It does not reproduce the complete BlueField hardware pipeline, firewall implementation or security certification properties.

NVIDIA DOCA Technical Documentation
NETWORK INSIGHT
Engineering Guide 06 / Silicon Security Fortress
NETWORK INSIGHT
NVIDIA BlueField DPU Architecture
SILICON OFFLOAD EDITION
SECTION 06 / STORAGE INFRASTRUCTURE

Decoupling Compute from Storage Storage Offloading and NVMe-oF

Engineering high-performance distributed storage infrastructure using BlueField DPUs, NVMe device emulation, remote storage fabrics, RDMA transport, storage virtualisation and accelerated I/O processing.

BLUEFIELD — DISAGGREGATED STORAGE ARCHITECTURE
BlueField disaggregated storage architecture Host applications access an emulated PCIe NVMe controller. BlueField storage services map the host-visible storage device to a remote storage backend through a supported network transport. Remote storage controllers manage persistent media. HOST COMPUTE ENVIRONMENT DATABASE WORKLOAD VIRTUAL MACHINE AI DATA PIPELINE HOST BLOCK LAYER / NATIVE NVMe DRIVER PCIe — HOST-VISIBLE NVMe DEVICE BLUEFIELD DPU — STORAGE PROCESSING DOMAIN NVMe CONTROLLER EMULATION Host-visible controller / namespaces / I/O queues SNAP STORAGE SERVICES BACKEND STORAGE MAPPING Controller and namespace management Supported storage service integration NETWORK TRANSPORT / SUPPORTED DATA-PATH ACCELERATION STORAGE NETWORK FABRIC Example: NVMe over RDMA or supported TCP backend REMOTE STORAGE SYSTEM / PERSISTENT MEDIA NVMe STORAGE POOL A NVMe STORAGE POOL B NVMe STORAGE POOL C Persistent block storage Persistent block storage Persistent block storage
PCIe and storage control Storage processing and return path Remote storage transport
Conceptual BlueField storage virtualisation architecture. The host-visible NVMe controller can be backed by supported remote storage services. Exact data paths, emulation capabilities and hardware acceleration depend on the BlueField generation, SNAP release, backend implementation and configuration.
STORAGE ARCHITECTURE

Why modern data centres are disaggregating storage

Traditional server architectures frequently associate computing resources with storage devices installed directly inside the same physical server.

Applications execute on the host CPU and access locally attached storage through operating system drivers, storage controllers and PCIe interfaces.

Although this architecture can deliver excellent performance, it creates a physical relationship between compute capacity and storage capacity. Scaling one resource may require purchasing or reconfiguring infrastructure associated with the other.

Disaggregated storage separates persistent storage resources from the servers consuming those resources. Compute nodes can access storage capacity provided by dedicated storage systems across a network fabric.

BlueField can participate in this architecture by moving selected storage virtualisation, transport and infrastructure processing functions away from the host CPU.

The objective is to make remote storage appear operationally familiar to the host while allowing the underlying storage infrastructure to scale and evolve independently.
CPU

Independent compute scaling

Increase application computing capacity without necessarily increasing locally installed persistent storage capacity.

POOL

Shared storage infrastructure

Allocate storage capacity from managed backend systems according to application requirements and infrastructure policy.

DPU

Infrastructure offloading

Move supported storage processing and virtualisation responsibilities into a dedicated infrastructure domain.

STORAGE PROTOCOL FUNDAMENTALS

Understanding NVMe storage architecture

Non-Volatile Memory Express, or NVMe, defines a storage command and controller architecture designed for efficient access to non-volatile storage resources.

Unlike older storage interfaces designed around different generations of storage technology, NVMe supports a highly parallel queue-based command processing model.

For locally attached NVMe devices, PCIe provides the underlying connectivity between the host and the storage controller.

METALLIC HARDWARE CUTAWAY — NVMe STORAGE DEVICES
NVMe DEVICE 01
NVMe CONTROLLER
NAND 01 NAND 02 NAND 03 NAND 04
NVMe DEVICE 02
NVMe CONTROLLER
NAND 01 NAND 02 NAND 03 NAND 04
NVMe DEVICE 03
NVMe CONTROLLER
NAND 01 NAND 02 NAND 03 NAND 04
Stylised NVMe SSD hardware cutaways showing controller, flash memory and connector resources. Not a specific commercial drive or physical component layout.
CTRL

NVMe controller

Implements the applicable NVMe command processing model and exposes storage resources to the host.

NS

Namespaces

Logical block-addressable storage resources accessible through an NVMe controller.

SQ

Submission queues

Hold commands submitted by host software for processing by the controller.

CQ

Completion queues

Communicate command completion status and associated completion information back to host software.

DMA

Direct memory access

Supports eligible transfers between device and host memory without requiring the CPU to copy every byte individually.

LBA

Logical block addressing

Identifies logical storage blocks within an accessible namespace independently of the underlying physical media layout.

COMMAND PROCESSING

NVMe submission and completion queues

The NVMe queue architecture allows multiple commands to be outstanding simultaneously. Host software can submit additional work without waiting for every previous operation to finish.

This parallelism is important for modern storage devices capable of processing many concurrent operations.

NVMe — LOGICAL COMMAND AND COMPLETION PROCESSING
SUBMISSION QUEUE
CID 104 READ
CID 105 WRITE
CID 106 READ
CID 107 FLUSH
AVAILABLE ---
NVMe CONTROLLER
Fetch commands
Process I/O
Post completions
COMPLETION QUEUE
CID 101 SUCCESS
CID 103 SUCCESS
CID 102 SUCCESS
AVAILABLE ---
AVAILABLE ---
Illustrative queue snapshot. Command identifiers associate completions with submitted commands. Commands can complete out of submission order, subject to applicable command semantics and ordering requirements.

Doorbells and queue processing

In a typical PCIe NVMe implementation, submission and completion queues reside in accessible memory. Host software places commands into submission queues and uses controller doorbell mechanisms to communicate queue updates.

The controller retrieves applicable commands, performs the requested operations and posts completion entries. Host software discovers completions through interrupt-driven or polling mechanisms, depending on the implementation.

The controller may be a physical NVMe SSD controller or a supported emulated NVMe controller implemented through infrastructure such as BlueField.

QUEUE DEPTH IS NOT THE SAME AS QUEUE COUNT

Queue depth describes the number of entries available or outstanding within a queue context. Queue count describes the number of queues configured or supported. Increasing either can affect concurrency, resource consumption and latency.

STORAGE PATH COMPARISON

Local NVMe versus DPU-backed remote NVMe

DIRECT-ATTACHED NVMe
Application
Operating system block layer
Native NVMe driver
PCIe interface
Physical NVMe SSD controller
Local persistent storage media

Storage commands are processed by a locally attached physical controller. The storage device and compute environment share a direct physical attachment.

BLUEFIELD-BACKED REMOTE NVMe
Application
Operating system block layer
Native NVMe driver
PCIe interface
DPU INFRASTRUCTURE DOMAIN
Emulated NVMe controller Storage virtualisation and backend mapping
Network storage transport
Remote persistent storage system

The host accesses a familiar storage interface while supported infrastructure services map operations to a remote storage backend.

The architectural advantage is not that remote storage becomes physically identical to local storage. It is that the host-facing storage interface can remain familiar while the underlying infrastructure changes.

A locally presented NVMe device does not necessarily mean that the persistent storage media is physically installed inside the host.
NETWORK STORAGE PROTOCOLS

NVMe over Fabrics architecture

NVMe over Fabrics, commonly abbreviated NVMe-oF, extends NVMe command processing across supported network fabrics.

Rather than communicating exclusively through a local PCIe connection, an NVMe host can communicate with an NVMe subsystem using an appropriate fabric transport.

The architecture preserves important NVMe storage concepts while introducing transport-specific connection establishment, command delivery, data transfer and completion mechanisms.

NVMe-oF — INITIATOR, FABRIC AND TARGET
NVMe INITIATOR NVMe COMMANDS FABRIC CONTROLLER TRANSPORT ENDPOINT RDMA / TCP / FC as applicable STORAGE FABRIC COMMAND / DATA TRANSFER COMPLETION DELIVERY NVMe SUBSYSTEM TARGET CONTROLLER NS 01 NS 02 BACKEND STORAGE NVMe semantics transported across a supported fabric
Logical NVMe-oF architecture. Transport-specific connection, queue and data-transfer mechanisms differ between RDMA, TCP and Fibre Channel. Not all transports are supported by every BlueField storage software configuration.
Transport Architecture Engineering considerations
Local PCIe NVMe Direct PCIe connectivity between host and physical or emulated controller. PCIe bandwidth, queue resources, memory mappings and device configuration.
NVMe/RDMA NVMe-oF transport using RDMA-capable infrastructure. Memory registration, queue pairs, fabric congestion and RDMA configuration.
NVMe/TCP NVMe-oF transport operating over TCP/IP. TCP processing, network latency, retransmissions and available acceleration.
NVMe/FC NVMe transport using Fibre Channel storage networking. Fibre Channel infrastructure, zoning, compatibility and storage fabric design.
BLUEFIELD STORAGE VIRTUALISATION

NVIDIA BlueField SNAP storage architecture

NVIDIA SNAP storage technology enables supported storage device emulation and virtualisation through BlueField infrastructure.

A host can discover a supported emulated storage controller through PCIe and access its exposed storage resources using an appropriate native host driver.

The DPU storage service manages the relationship between the host-facing device and its configured storage backend.

This separation allows infrastructure engineers to manage storage connectivity and virtualisation independently of ordinary application execution.

SNAP — HOST DEVICE TO BACKEND STORAGE MAPPING
HOST-VISIBLE DEVICE A HOST-VISIBLE DEVICE B NVMe CONTROLLER A / NS 1 NVMe CONTROLLER B / NS 1 BLUEFIELD SNAP STORAGE SERVICES EMULATED CONTROLLER A EMULATED CONTROLLER B BACKEND MAPPING AND STORAGE MANAGEMENT Configured namespace mappings and supported backend services BACKEND STORAGE A BACKEND STORAGE B Configured remote storage resource Configured remote storage resource
Conceptual SNAP device and namespace mapping. Supported controller types, namespace management, backend integrations, hot-plug behaviour and lifecycle operations depend on the installed hardware and software release.
EMU

Device emulation

Present supported storage device interfaces to host software through PCIe.

MAP

Backend mapping

Associate host-visible storage resources with configured backend storage services.

I/O

Accelerated processing

Use supported hardware and software data paths to process eligible storage operations efficiently.

NS

Namespace management

Configure the logical storage resources exposed through supported NVMe controllers.

LIFE

Device lifecycle

Manage supported controller creation, attachment, removal and recovery operations.

OBS

Operational visibility

Observe storage service health, controller state, backend connectivity and I/O evidence.

SNAP IS NOT A PERSISTENT STORAGE MEDIUM

SNAP provides storage virtualisation and supported device emulation capabilities. Persistent data durability depends on the configured backend storage architecture, acknowledgement semantics and applicable protection mechanisms.

HIGH-PERFORMANCE STORAGE SOFTWARE

SPDK and user-space storage processing

The Storage Performance Development Kit, or SPDK, provides libraries and tools for constructing high-performance storage applications.

SPDK supports user-space storage processing techniques, asynchronous I/O and polling-based execution models designed to reduce overhead associated with conventional storage processing.

Supported BlueField storage deployments can integrate SPDK-based components into the infrastructure storage processing architecture.

CONVENTIONAL KERNEL STORAGE PATH
Application
System call / kernel interface
Kernel storage processing
Storage driver
Storage controller

Kernel-based storage paths provide mature operating system integration and can also achieve high performance using modern asynchronous I/O mechanisms.

SPDK-BASED USER-SPACE PATH
Storage application
SPDK user-space libraries
Asynchronous processing / polling
Supported device access or transport
Storage controller or backend

User-space processing can reduce selected software overheads, but polling and dedicated processing resources introduce their own capacity and configuration considerations.

POLLING IS NOT FREE

Polling can reduce notification and scheduling overhead, but dedicated polling threads may consume CPU resources even when storage traffic is relatively low. DPU Arm core utilisation must therefore be interpreted in the context of the storage execution model.

REMOTE MEMORY AND STORAGE TRANSPORT

RDMA and accelerated remote storage access

Remote Direct Memory Access enables supported network adapters to transfer data involving registered memory regions across a network.

RDMA can reduce selected memory-copy operations, kernel processing and CPU involvement in high-performance data transfers.

In NVMe/RDMA deployments, the storage transport uses RDMA mechanisms to exchange commands, transfer data and communicate completion information according to the applicable transport specification.

RDMA — REGISTERED MEMORY TRANSFER MODEL
INITIATOR SYSTEM TARGET SYSTEM STORAGE SOFTWARE STORAGE SOFTWARE Resources / work requests / completions Resources / permissions / backend I/O REGISTERED MEMORY REGISTERED MEMORY RDMA-CAPABLE INTERFACE RDMA-CAPABLE INTERFACE Queue pairs / transport processing Queue pairs / transport processing RDMA FABRIC Data transport
Generic RDMA memory-transfer model. RDMA read, write and send/receive operations have different semantics. NVMe/RDMA selects appropriate mechanisms according to command direction and transport requirements.
MR

Memory registration

Establish memory regions and applicable access permissions for supported RDMA operations.

QP

Queue pairs

Provide transport work queues and associated communication state for RDMA operations.

WR

Work requests

Describe supported operations submitted to RDMA processing resources.

CQ

RDMA completions

Provide completion information for applicable transport work requests. These are distinct from NVMe completions.

ECN

Congestion management

Manage congestion and transport behaviour using mechanisms appropriate to the selected RDMA fabric.

KEY

Memory access protection

Restrict supported memory operations through registered regions, access keys and associated protection mechanisms.

RDMA COMPLETION DOES NOT MEAN DATA IS DURABLE

Successful network data transfer is not equivalent to persistent storage completion. Storage command semantics, volatile caches, flush operations, force-unit-access behaviour and backend durability mechanisms determine when data can be considered persistent.

END-TO-END I/O PROCESSING

Following a storage read through BlueField

Consider a database application reading data from a host-visible NVMe namespace backed by a remote storage system.

The application does not necessarily need to understand the remote storage topology. Its storage operation is processed through the host storage interface and the configured DPU storage infrastructure.

01

Application issues a storage read

The application requests data through an appropriate operating system or direct I/O interface. A cache hit may avoid device I/O entirely.

02

Host submits an NVMe command

When device access is required, the host storage stack submits an NVMe read command identifying the namespace and requested logical blocks.

03

BlueField processes the host-facing command

The emulated controller and associated storage service receive and process the applicable host command.

04

Resolve the backend storage mapping

The storage infrastructure determines the configured backend resource associated with the host-visible namespace.

05

Submit the backend storage operation

The appropriate storage service issues the remote operation using the supported backend protocol and transport.

06

Remote storage retrieves the data

The backend storage system processes the request and obtains data from its applicable cache or persistent media.

07

Return data through the configured data path

The requested data is transferred toward the host using supported network, memory-access and PCIe mechanisms. Exact buffer placement depends on the implementation.

08

Complete the host NVMe command

The emulated controller reports the applicable completion status after satisfying the required command semantics.

09

Application receives the result

The host storage stack completes the application request, allowing processing to continue or reporting an applicable storage error.

One application storage operation can cross multiple independently managed processing domains: the host, PCIe interface, DPU storage service, network fabric and remote storage system.
PERFORMANCE ENGINEERING

Understanding IOPS, throughput and latency

Storage performance cannot be represented accurately by a single metric.

A storage architecture that performs well for large sequential reads may behave very differently when processing small random writes, synchronous database operations or mixed multi-tenant workloads.

STORAGE PERFORMANCE — ILLUSTRATIVE WORKLOAD
OPERATIONS PER SECOND 250,000

Example sustained I/O rate.

I/O REQUEST SIZE 4 KiB

Fixed-size example storage requests.

PAYLOAD THROUGHPUT 1.024 GB/s

Calculated application data throughput.

Hypothetical workload values used to explain storage performance relationships. These are not NVIDIA BlueField benchmark results.
THROUGHPUT RELATIONSHIP
Throughput = IOPS × I/O Size

250,000 × 4,096 bytes = 1,024,000,000 bytes/s

The same IOPS rate produces different throughput depending on the amount of data transferred per operation.

Actual network bandwidth consumption also includes applicable protocol overhead, acknowledgements, control messages and retransmissions.

Queue depth and outstanding I/O

Maintaining multiple outstanding operations can improve utilisation of storage processing resources. However, excessive concurrency can increase queueing delays and degrade tail latency.

LITTLE'S LAW — STEADY-STATE RELATIONSHIP
Outstanding I/O ≈ IOPS × Average Latency

250,000 IOPS × 0.0001 seconds = 25 outstanding operations

This example assumes a stable system and consistent measurement boundaries. It describes the average number of outstanding operations, not a universal recommended queue-depth setting.

IOPS

Number of completed storage operations per second for a defined workload.

Throughput

Amount of storage data transferred per unit of time.

Average latency

Mean operation completion time across the measured request population.

P99 latency

The approximate latency threshold at or below which 99 percent of measured operations complete.

Queue utilisation

Degree to which configured processing queues and outstanding-operation resources are being consumed.

CPU cost per I/O

Host or infrastructure processing resources consumed relative to the completed storage workload.

LATENCY INVESTIGATION

Building an end-to-end storage latency budget

Remote storage introduces additional processing and communication stages compared with a directly attached storage device.

Offloading can reduce selected processing costs, but the resulting application latency depends on the complete storage path.

STORAGE LATENCY — HYPOTHETICAL SERIAL BUDGET
Example direct-attached storage 80 µs
Example DPU-backed remote storage 100 µs
Host processing PCIe DPU processing Network Storage processing
Synthetic educational example, not measured performance. Each bar is normalised to its own total. Real storage stages can overlap, and latency components require consistent measurement boundaries to avoid double-counting.

In this hypothetical example, the remote storage architecture has higher end-to-end latency despite reduced host processing.

This illustrates an important engineering distinction: reducing host CPU overhead does not automatically reduce total application I/O latency.

Storage offloading is an infrastructure resource optimisation. Whether it also improves latency depends on the complete workload and storage architecture.
DATA CENTRE STORAGE NETWORKING

Engineering the remote storage fabric

A disaggregated storage architecture depends on the network for access to persistent data. Network performance and availability therefore become storage infrastructure concerns.

LEAF-SPINE — REDUNDANT COMPUTE AND STORAGE FABRIC
SPINE 01 SPINE 02 COMPUTE LEAF A COMPUTE LEAF B STORAGE LEAF A STORAGE LEAF B BLUEFIELD DPU BLUEFIELD DPU COMPUTE NODE 01 COMPUTE NODE 02 STORAGE TARGET STORAGE TARGET Illustrative storage route through a redundant fabric
Conceptual dual-connected compute and storage infrastructure. Physical link redundancy does not automatically provide storage multipathing or application-transparent recovery. These require appropriate transport, controller and backend configurations.

Fabric bandwidth

Ensure network capacity is appropriate for aggregate storage throughput, workload concurrency and protocol overhead.

Congestion control

Engineer congestion behaviour for the selected storage transport, especially latency-sensitive RDMA deployments.

Path redundancy

Provide independent connectivity and validate storage recovery behaviour during applicable network failures.

Traffic isolation

Separate or appropriately prioritise storage traffic according to security, performance and availability requirements.

MTU consistency

Verify compatible packet sizing across endpoints and the network path, including applicable encapsulation overhead.

End-to-end telemetry

Correlate network counters, storage latency, queue state and backend performance during investigations.

STORAGE AVAILABILITY

Multipathing, failover and storage recovery

Remote storage access introduces dependencies on network paths, transport connections, infrastructure services and remote storage controller availability.

NVMe multipathing can provide access to a namespace through multiple supported controller paths, subject to the storage subsystem and host configuration.

Asymmetric Namespace Access, or ANA, allows supported NVMe subsystems to communicate information about namespace accessibility through particular controller paths.

In a DPU-backed storage architecture, backend multipathing may be managed within the infrastructure domain rather than being directly visible to the host.

Failure domain Possible effect Required validation
Network link Loss of an active storage transport path. Alternate connectivity and transport recovery behaviour.
Storage target Controller or namespace becomes unavailable. Supported multipathing, ANA state and backend availability.
DPU storage service Host-visible device processing may stall or fail. Service recovery, outstanding I/O handling and device lifecycle behaviour.
DPU reset PCIe device and storage service disruption. Controller recovery, namespace mapping persistence and host timeout behaviour.
Backend media Data access failure or degraded performance. Backend redundancy, replication, recovery and data integrity.
Management service Configuration changes or reconciliation may become unavailable. Existing I/O continuity and supported management failure behaviour.
REDUNDANT NETWORKING IS NOT STORAGE REDUNDANCY

Multiple network links can protect against selected connectivity failures, but they do not automatically protect against storage controller failure, data corruption, DPU failure or loss of persistent media. Each failure domain requires an appropriate resilience mechanism.

DATA INTEGRITY AND PERSISTENCE

Write acknowledgement and storage durability

Storage virtualisation must preserve the required command semantics across the host-facing controller and backend storage architecture.

A successful write completion does not universally imply that data has reached non-volatile media. Volatile write caches and configured storage behaviour influence the durability guarantees associated with a completed operation.

ACK

Write completion

Indicates successful command completion according to the applicable controller and storage command semantics.

FUA

Force Unit Access

Requests applicable non-volatile persistence behaviour for an individual write operation according to the command specification.

FLUSH

Flush operations

Request persistence of applicable cached data and metadata according to the storage protocol's defined scope.

Infrastructure engineers must verify that storage emulation and backend translation preserve the guarantees expected by databases, filesystems and other persistence-sensitive applications.

Fast write acknowledgement is valuable only when the application receives the durability guarantees it was designed to depend on.
STORAGE INFRASTRUCTURE SECURITY

Protecting virtualised and remote storage resources

Storage disaggregation creates additional security boundaries between application workloads, DPU storage services, network transports and backend storage systems.

A host-visible namespace must be associated with the correct authorised backend resource. Incorrect mapping or insufficient access controls can expose sensitive storage data to unauthorised workloads.

Namespace authorisation

Ensure each workload receives access only to its intended storage resources.

Protected management

Restrict controller creation, backend mapping and storage lifecycle operations to authorised infrastructure administrators.

Transport protection

Use appropriate authentication, network isolation and supported encryption mechanisms for the selected storage transport.

Memory access controls

Protect applicable DMA and RDMA memory operations through configured permissions and platform isolation.

Data-at-rest protection

Apply appropriate storage encryption and key-management controls within the persistent storage architecture.

Tenant lifecycle

Validate resource removal, access revocation and data sanitisation when storage allocations change ownership.

STORAGE TROUBLESHOOTING

Investigating storage latency and I/O failures

A storage performance problem observed by an application may originate from any processing stage along the storage path.

Engineers should avoid assuming that a slow storage operation necessarily indicates a slow physical storage device.

INCIDENT TELEMETRY — STORAGE CONGESTION INVESTIGATION
HIGH MEDIUM LOW BASELINE ONSET DEGRADED I/O RECOVERY VALIDATION Application I/O latency Network congestion Backend service latency
Synthetic normalised telemetry, not measured BlueField performance. Correlated congestion and application latency suggest a network-related hypothesis but do not independently establish the root cause.

Host-side investigation

HOST — READ-ONLY STORAGE DIAGNOSTICS
# Inspect PCIe devices and drivers
lspci -nnk

# Inspect discovered NVMe controllers
nvme list
nvme list-subsys

# Inspect controller capabilities
nvme id-ctrl /dev/nvme0

# Inspect namespace information
nvme id-ns /dev/nvme0n1

# Inspect available NVMe error information
nvme error-log /dev/nvme0

# Observe extended block-device statistics
iostat -xz 1

# Inspect storage-related kernel messages
journalctl -k | grep -Ei 'nvme|timeout|reset|pcie'
Example Linux inspection commands. Device names are illustrative and must be replaced with the actual discovered devices. Some commands require additional packages or privileges. An emulated controller may expose different diagnostic information from a physical SSD.

DPU-side and fabric investigation

BLUEFIELD — STORAGE AND TRANSPORT EVIDENCE
# Inspect infrastructure network interfaces
ip -br link
ip -s link

# Inspect device and firmware information
devlink dev info

# Inspect supported interface counters
ethtool -S INTERFACE

# Inspect RDMA resources where applicable
rdma link show
rdma resource show

# Inspect infrastructure CPU utilisation
top

# Inspect failed system services
systemctl --failed

# Inspect applicable storage service events
journalctl -u STORAGE_SERVICE --since "1 hour ago"
Generic Linux and RDMA inspection examples. SNAP controller, namespace and backend diagnostics require the management tools appropriate to the installed SNAP release. Containerised deployments may require container-specific inspection mechanisms.
PRODUCTION ENGINEERING

BlueField storage troubleshooting matrix

Observed symptom Possible cause Evidence to investigate
NVMe controller not discovered Emulation configuration, PCIe enumeration, device lifecycle or host driver problem. PCIe discovery, controller configuration and host kernel messages.
Controller visible but namespace missing Missing namespace attachment, backend mapping or storage configuration. Controller and namespace state, backend resource mapping.
High application I/O latency Queue saturation, network congestion, DPU processing or backend storage delays. End-to-end latency breakdown, queue state and correlated telemetry.
Low storage throughput Insufficient concurrency, PCIe limitation, network bottleneck or backend capacity. I/O size, queue depth, negotiated PCIe characteristics and network utilisation.
RDMA connection failure Addressing, routing, resource configuration or incompatible transport settings. RDMA link state, transport resources, network reachability and connection logs.
Intermittent storage timeouts Packet loss, congestion, transport recovery or backend availability problems. Network counters, timeout logs, backend service state and event timelines.
Unexpected DPU CPU utilisation Polling threads, software processing, resource imbalance or unsupported offload. Per-core utilisation, storage service execution model and offload evidence.
Storage failure after network disruption Incomplete multipath configuration or unsuccessful transport recovery. Connection state, alternate paths, controller state and recovery logs.
Storage inaccessible after DPU restart Missing controller recreation, configuration persistence or backend recovery. Startup logs, emulation state, namespace mappings and host enumeration.
Unexpected write durability behaviour Cache configuration or incorrect preservation of persistence semantics. Controller capabilities, backend guarantees and controlled durability tests.
AI AND HIGH-PERFORMANCE COMPUTING

Why storage offloading matters for AI infrastructure

AI training and inference platforms require storage infrastructure capable of supplying datasets, model weights, checkpoints and application data at appropriate rates.

Expensive accelerator resources can become underutilised when storage and data preparation pipelines cannot supply data quickly enough.

BlueField storage offloading can contribute to a broader infrastructure architecture that separates application computation from selected storage and networking processing responsibilities.

DATA

Training datasets

Deliver large datasets from shared storage infrastructure to compute nodes.

CKPT

Model checkpointing

Support storage pipelines for periodic model-state persistence and recovery.

MODEL

Model loading

Supply model weights and related resources to inference and training environments.

BLUEFIELD STORAGE OFFLOAD AND GPUDIRECT STORAGE

DPU-backed storage virtualisation and GPUDirect Storage are distinct architectural capabilities. A host-visible emulated NVMe device does not automatically establish a direct storage-to-GPU data path. GPUDirect Storage requires compatible hardware, drivers, software and supported storage configurations.

ENGINEERING TAKEAWAY

BlueField as a programmable storage infrastructure platform

NVIDIA BlueField extends the role of a network adapter into a broader infrastructure processing platform capable of supporting selected storage virtualisation and acceleration functions.

Through supported storage device emulation, host applications can access familiar storage interfaces while infrastructure services manage the underlying relationship with remote storage resources.

NVMe-oF and RDMA can provide efficient remote storage communication mechanisms, while storage software such as SPDK can reduce selected processing overheads.

Successful production deployments require careful engineering of PCIe resources, queue processing, network capacity, backend storage performance, security, data durability and failure recovery.

BlueField storage offloading is not simply about making individual storage operations faster. It is about creating a more programmable infrastructure architecture in which compute, networking and persistent storage can be managed as independently scalable resources.
NETWORK INSIGHT — ENGINEERING GUIDES BLUEFIELD DPU / SECTION 06
Network Insight / Interactive Engineering 06

Inside the Accelerated Storage Fabric

Follow an NVMe storage operation through application memory, PCIe, BlueField infrastructure services, RDMA transport and remote solid-state storage. Investigate where storage acceleration occurs and discover which infrastructure resource limits application performance.

SILICON STORAGE FABRIC NVMe-oF RDMA NVMe EMULATION DMA DATA MOVEMENT STORAGE TROUBLESHOOTING
01 / Storage engineering scenarios

Select an application workload

02 / Storage control centre

Configure the storage infrastructure

03 / Animated storage architecture
STORAGE PATH READY
COMPUTE SERVER / STORAGE CUTAWAY HOST COMPUTE DOMAIN APPLICATION Database workload HOST CPU Application / I/O stack HOST MEMORY BUFFER SUBMISSION QUEUE COMPLETION QUEUE PCIe INTERFACE 14 GB/s payload capacity BLUEFIELD / INFRASTRUCTURE STORAGE DOMAIN VIRTUAL NVMe STORAGE FRONTEND Namespace presentation ARM PROCESSING Storage service logic DMA ENGINE Buffer data movement CONNECTX RDMA transport DPU-MANAGED STORAGE PRESENTATION DATA CENTRE STORAGE FABRIC 100 Gb/s Ethernet / NVMe-RDMA REMOTE NVMe STORAGE TARGET NVMe-oF CONTROLLER Namespace / I/O execution TARGET ONLINE NVMe SOLID-STATE STORAGE ARRAY Conceptual storage architecture — not a physical silicon layout
Execute an I/O operation or step through the storage journey.
Estimated IOPS
0
Throughput
0

GB/s

Model latency
0

µs

Host CPU demand
0

Illustrative units

Performance values are calculated by an illustrative educational model. They are not NVIDIA BlueField benchmark measurements.

04 / NVMe command lifecycle

Submission and completion queue explorer

Submission queue / host memory

Awaiting submission of an NVMe command.

Completion queue / host memory

Awaiting controller completion.

NVMe command versus data movement

Submission queue entries describe operations. The actual application payload resides in separate memory buffers. Completion queue entries report command status after the controller completes or rejects the operation. The eight displayed slots are an illustrative window, not the configured queue capacity.

05 / Storage transport inspector

Observe the storage protocol representation

Conceptual command transport
Conceptual data movement

These blocks illustrate logical protocol relationships. They are not byte-accurate Wireshark packet captures.

06 / Storage investigation console

Follow command and completion evidence

Diagnostic messages are generated by the educational model rather than actual DOCA, Linux or NVMe firmware commands.

07 / Storage performance investigation

Identify the limiting infrastructure resource

Change queue depth, block size, transport, network bandwidth and target capacity. Observe how the lowest effective resource ceiling constrains application throughput.

RESOURCE EFFECTIVE CEILING MODEL INTERPRETATION
08 / Controlled architecture comparison

Host-managed versus DPU-managed storage

Compare both architectures using the same workload, transport, network capacity, storage target and queue depth.

Architecture A

Host-managed NVMe-oF

Not tested

Host software manages the storage initiator and transport coordination.

Architecture B

DPU-managed storage presentation

Not tested

Selected infrastructure storage functions are moved into the DPU domain.

Compare architectures without modifying the active storage configuration.
09 / Infrastructure fault injection

Introduce a storage infrastructure failure

No fault injected. Select a failure and investigate the resulting storage behaviour.
10 / Production storage incident

Incident 006 — The starved AI data pipeline

An AI training environment is experiencing inadequate dataset delivery. The remote storage array is capable of substantially higher throughput, but the application is failing to receive data at the expected rate.

Investigate transport readiness, storage namespace accessibility, queue depth, PCIe capacity and network congestion. Restore a working accelerated storage path with at least 8 GB/s of modelled application throughput.

○ Establish an eligible DPU-managed RDMA path.
○ Restore registered memory and namespace access.
○ Restore normal network fabric conditions.
○ Achieve at least 8 GB/s estimated throughput.
○ Verify a successful NVMe READ completion.
Load the incident to begin your investigation.
11 / Engineering interpretation

Understanding accelerated storage architecture

NVMe device presentation

Supported DPU storage architectures can present a virtual NVMe controller to a host while infrastructure software manages access to backend storage. The host does not necessarily manage the remote storage transport directly.

DMA and CPU involvement

DMA allows devices to move data between eligible memory buffers without requiring the CPU to copy every byte. CPUs still participate in setup, command submission, memory management and completion handling.

NVMe over RDMA

NVMe/RDMA uses RDMA transport services to carry NVMe commands and transfer data. Registered memory, queue pairs and appropriate access permissions are important elements of the architecture.

Queue depth and concurrency

Multiple outstanding I/O operations help hide storage and network latency. Increasing queue depth eventually stops improving throughput when another resource becomes saturated.

Storage completion semantics

A successful NVMe WRITE completion does not universally guarantee that data has reached persistent media. Volatile write caching, Force Unit Access, Flush commands and controller behaviour affect durability.

End-to-end performance limitations

A faster DPU or network link cannot eliminate a slow storage target, restricted PCIe connection, insufficient queue concurrency or unavailable namespace. Storage performance must be investigated across the entire I/O path.

View educational performance model assumptions

Throughput is the minimum of five simplified resource ceilings: network payload capacity, PCIe payload capacity, target storage bandwidth, storage processing capacity and queue concurrency.

Queue concurrency ceiling in bytes per second equals queue depth multiplied by block size in bytes, divided by assumed service latency in seconds.

Network efficiency is assumed to be 90% for RDMA and 82% for TCP. Congestion applies capacity multipliers of 1.0, 0.65 and 0.25. These coefficients are teaching assumptions, not measured protocol efficiencies.

Illustrative processing ceilings are 1.2 million IOPS for accelerated DPU-managed RDMA, 650,000 for DPU software processing, 800,000 for host-managed RDMA and 450,000 for host-managed TCP.

Host CPU demand is expressed in arbitrary workload units. It is not CPU utilisation, processor core count or measured CPU cycles.

This model does not reproduce detailed queueing latency, PCIe transaction ordering, storage caching, SSD endurance, RDMA retransmissions, PFC behaviour or specific BlueField firmware implementation details.

BlueField-3 is the architectural reference. Actual NVMe emulation, storage backend integration, acceleration eligibility and software fallback depend on the deployed NVIDIA DOCA or storage software stack and supported device configuration.

NVIDIA DOCA Technical Documentation
NETWORK INSIGHT
Engineering Guide 06 / Silicon Storage Fabric
NETWORK INSIGHT
NVIDIA BlueField DPU Architecture
SILICON OFFLOAD EDITION
SECTION 07 / AI SUPERCOMPUTING FABRIC

Engineering the AI Factory BlueField in AI and GPU Infrastructure

Understanding the relationship between accelerated computing, GPU memory, NVLink, NVSwitch, GPUDirect RDMA, BlueField infrastructure services, Spectrum-X, InfiniBand and distributed AI communication.

AI FACTORY — COMPUTE AND INFRASTRUCTURE DOMAINS
Conceptual AI factory infrastructure Two GPU compute nodes communicate through an accelerated scale-out network. Separate BlueField infrastructure services provide supported networking, security and storage processing. GPU scale-up connections remain distinct from infrastructure processing. ACCELERATED SCALE-OUT COMPUTE FABRIC FABRIC SWITCH A FABRIC SWITCH B Example: Spectrum-X Ethernet or InfiniBand architecture AI COMPUTE NODE 01 AI COMPUTE NODE 02 RDMA-CAPABLE COMPUTE ADAPTER RDMA-CAPABLE COMPUTE ADAPTER GPU 0 GPU 1 GPU 2 GPU 3 COMPUTE + HBM COMPUTE + HBM COMPUTE + HBM COMPUTE + HBM GPU SCALE-UP INTERCONNECT GPU SCALE-UP INTERCONNECT HOST CPU HOST CPU Application orchestration Application orchestration BLUEFIELD DPU BLUEFIELD DPU Infrastructure services Infrastructure services STORAGE / SECURITY / VIRTUAL NETWORKING STORAGE / SECURITY / VIRTUAL NETWORKING LOGICAL INFRASTRUCTURE NETWORK Storage access / management / tenant connectivity DATASET STORAGE INFRASTRUCTURE CONTROL TENANT SERVICES
Scale-out compute communication GPU scale-up interconnect DPU infrastructure services Host processing and control
Conceptual AI factory architecture rather than a specific NVIDIA reference design. Compute and infrastructure networks may use dedicated or shared physical resources. Adapter selection, GPU connectivity and DPU placement depend on the platform architecture.
AI INFRASTRUCTURE ARCHITECTURE

Why AI infrastructure is becoming a networked computer

Modern artificial intelligence infrastructure increasingly operates as a distributed computing system rather than a collection of independent application servers.

Large AI models may require computational resources, memory capacity and communication bandwidth that exceed the capabilities of a single accelerator or physical server.

Distributed training divides computational work across multiple GPUs. These GPUs must exchange gradients, model parameters, activation data or other intermediate results according to the selected parallelism strategy.

At the same time, the infrastructure must provide storage access, network connectivity, workload isolation, management services and security enforcement.

BlueField addresses selected infrastructure processing responsibilities, allowing the host CPU and GPU resources to concentrate more effectively on application computation.

An AI factory is not simply a large collection of GPUs. It is a coordinated system of compute, memory, networking, storage and infrastructure services whose collective performance determines application efficiency.
CPU

Host computing

Executes application orchestration, operating system functions, data preparation and host-side runtime responsibilities.

GPU

Accelerated computing

Performs highly parallel mathematical operations, tensor processing and supported AI computation.

DPU

Infrastructure computing

Executes supported networking, storage, security and infrastructure management functions within a dedicated processing domain.

ACCELERATED COMPUTE HARDWARE

Understanding GPU compute and high-bandwidth memory

AI accelerators combine highly parallel computational resources with memory systems designed to supply large volumes of data to computational execution units.

High Bandwidth Memory, or HBM, provides substantial memory bandwidth through stacked memory devices and wide interfaces integrated into compatible accelerator packages.

The effectiveness of an AI workload depends not only on computational throughput but also on memory capacity, memory bandwidth and the ability to move data between GPUs.

METALLIC ACCELERATOR CUTAWAY — GPU AND HBM
ACCELERATOR PACKAGE 01
HBM HBM
GPU 0 COMPUTE SILICON
HBM HBM
ACCELERATOR PACKAGE 02
HBM HBM
GPU 1 COMPUTE SILICON
HBM HBM
GPU SCALE-UP COMMUNICATION
Example: supported NVLink and NVSwitch connectivity
Stylised GPU and HBM package cutaways. Memory stack count, silicon layout and interconnect representation are conceptual and do not depict a specific GPU product.

GPU memory and computational resources form the accelerated computing domain. BlueField does not replace these computational resources or perform the primary neural network training workload.

Its architectural role is to support selected infrastructure functions surrounding those computational resources.

GPU COMMUNICATION ARCHITECTURE

Scale-up versus scale-out GPU networking

AI infrastructure uses multiple communication architectures to connect accelerator resources. Two important architectural concepts are scale-up and scale-out networking.

SCALE-UP GPU COMMUNICATION
GPU computational resources
NVLink interfaces
Supported NVSwitch fabric
Peer GPU computational resources

High-bandwidth accelerator communication within a supported scale-up domain. Depending on the platform, this domain can extend beyond an individual server.

SCALE-OUT GPU COMMUNICATION
GPU computational resources
Supported GPU-to-adapter data path
RDMA-capable network adapter
Ethernet or InfiniBand fabric
Remote GPU computational resources

Distributed communication between compute nodes or scale-up domains through a high-performance network fabric.

Scale-up communication increases the amount of tightly interconnected accelerator resources available within a supported computational domain.

Scale-out communication connects these resources across a broader distributed infrastructure.

NVLINK IS NOT THE BLUEFIELD NETWORK DATA PATH

NVLink and NVSwitch provide accelerator interconnection capabilities. BlueField provides programmable infrastructure processing and supported network acceleration. These technologies solve different architectural problems and should not be treated as interchangeable.

DIRECT GPU MEMORY COMMUNICATION

Understanding NVIDIA GPUDirect RDMA

Conventional network communication involving GPU-resident data may require staging that data through host system memory before a network adapter can transmit it.

GPUDirect RDMA enables compatible third-party devices, including supported network adapters, to access GPU memory through supported peer-memory mechanisms.

This can eliminate selected intermediate host-memory copies and reduce CPU involvement in the movement of GPU-resident data.

GPU DATA PATH — HOST STAGING VERSUS DIRECT RDMA
CONVENTIONAL HOST-MEMORY STAGING GPU MEMORY HOST MEMORY NETWORK ADAPTER NETWORK DMA COPY DMA Intermediate host-memory staging SUPPORTED GPUDIRECT RDMA PATH GPU MEMORY HOST SOFTWARE CONTROL Registration / setup / synchronisation NETWORK ADAPTER RDMA DATA PATH SUPPORTED PEER-MEMORY DMA Avoid selected intermediate host-memory copies
Conceptual comparison of GPU data movement. GPUDirect RDMA requires compatible GPU, adapter, PCIe topology, drivers, memory registration and application software. Host software remains involved in setup and coordination.
MEM

GPU memory access

Supported peer-memory access allows compatible devices to transfer data involving registered GPU memory.

DMA

Direct data movement

Eligible transfers avoid selected intermediate copies through host memory.

PCIe

Platform topology

PCIe connectivity, root complexes, peer access and platform configuration influence supported data paths.

REG

Memory registration

Communication software establishes the memory mappings and resources required for supported transfers.

SYNC

Memory synchronisation

Software must preserve appropriate ordering and visibility between GPU computation and network operations.

OBS

Data-path verification

Engineers must verify the actual communication path rather than assume direct GPU access is active.

GPUDIRECT RDMA DOES NOT REQUIRE A DPU IN EVERY DESIGN

Compatible ConnectX adapters can support GPUDirect RDMA without a separate BlueField DPU. Supported BlueField configurations can also participate in accelerated networking. The chosen adapter and platform architecture determine the actual GPU communication path.

DISTRIBUTED COMPUTATIONAL ARCHITECTURE

How distributed AI training generates network traffic

Distributed training divides computational work and model state across multiple accelerator resources.

Different parallelism strategies create different communication patterns, message sizes, synchronisation requirements and network performance dependencies.

DP

Data parallelism

Model replicas process different training data. Gradient synchronisation commonly requires collective communication between participating workers.

TP

Tensor parallelism

Individual tensor computations are distributed across accelerators, often requiring frequent communication during model execution.

PP

Pipeline parallelism

Model layers are divided into stages. Activations and gradients move between participating pipeline stages.

EP

Expert parallelism

Mixture-of-experts workloads distribute expert computations and may generate substantial all-to-all communication.

FSDP

Sharded model state

Parameters, gradients and optimiser state can be partitioned across workers, introducing communication such as all-gather and reduce-scatter.

HYB

Hybrid parallelism

Large training deployments combine multiple parallelism strategies according to model architecture, memory capacity and available network topology.

The AI model architecture influences the network traffic pattern. The network architecture, in turn, influences how efficiently the model can be distributed.
COLLECTIVE COMMUNICATION

NCCL and GPU communication collectives

The NVIDIA Collective Communications Library, or NCCL, provides optimised communication primitives for supported multi-GPU and multi-node computing environments.

Collective operations allow participating processes to exchange or combine data according to defined communication semantics.

ALL-REDUCE — FOUR PARTICIPATING GPU RANKS
GPU RANK 0 LOCAL VALUE 2
GPU RANK 1 LOCAL VALUE 4
GPU RANK 2 LOCAL VALUE 6
GPU RANK 3 LOCAL VALUE 8
SUM REDUCTION RESULT 2 + 4 + 6 + 8 = 20 Every participating rank receives the reduced result.
GPU RANK 0 20
GPU RANK 1 20
GPU RANK 2 20
GPU RANK 3 20
Simplified scalar sum example explaining AllReduce semantics. Actual training collectives operate on buffers containing potentially large tensors.
Collective Communication behaviour Typical application
AllReduce Combines contributions and returns the reduced result to every rank. Distributed gradient synchronisation.
AllGather Collects contributions from all ranks and distributes the combined data. Reconstruction of distributed model state.
ReduceScatter Reduces input data and distributes portions of the result across ranks. Distributed gradient and state processing.
Broadcast Distributes data from a designated root rank to participating ranks. Parameter or configuration distribution.
All-to-all pattern Each participant exchanges distinct data portions with other participants. Expert routing and distributed mixture-of-experts processing.
COLLECTIVE NETWORK TOPOLOGY

Ring AllReduce and distributed communication

Ring AllReduce is one possible algorithm for implementing a collective reduction. Participating ranks exchange data with neighbouring ranks in a logical ring.

A common implementation divides the operation into reduce-scatter and all-gather phases. This distributes communication and reduction work across participating resources.

LOGICAL RING — FOUR GPU COMMUNICATION RANKS
GPU RANK 0 GPU RANK 1 GPU RANK 2 GPU RANK 3 LOCAL BUFFER LOCAL BUFFER LOCAL BUFFER LOCAL BUFFER RING ALLREDUCE PHASE 1 — REDUCE-SCATTER PHASE 2 — ALL-GATHER
Logical communication ring. NCCL can select different algorithms, protocols and channels according to the platform, topology, message size and software configuration.

Communication volume in a simplified ring

For an idealised ring AllReduce involving N ranks and an input buffer of S bytes per rank, each rank sends approximately the following amount of data across both phases.

IDEALISED RING ALLREDUCE
Bytes sent per rank = 2 × (N − 1) / N × S

For eight ranks and a 1 GB buffer: 2 × 7/8 × 1 GB = 1.75 GB per rank.

Each rank also receives approximately the same volume under this simplified model. Protocol overhead, algorithm selection, topology and communication scheduling influence actual traffic and execution time.

BLUEFIELD DOES NOT AUTOMATICALLY EXECUTE NCCL REDUCTIONS

NCCL collective computation and communication depend on the selected GPU and network implementation. BlueField infrastructure acceleration should not be confused with dedicated in-network collective acceleration technologies such as supported NVIDIA SHARP implementations.

HIGH-PERFORMANCE NETWORK FABRICS

Ethernet, RoCEv2 and InfiniBand in AI clusters

Distributed AI infrastructure requires network fabrics capable of transporting substantial volumes of accelerator data with predictable performance.

Ethernet and InfiniBand provide different architectural approaches to high-performance communication. Both can support RDMA-based workloads when implemented with appropriate hardware and software.

ETHERNET / RoCEv2
GPU application buffers
RDMA transport
UDP / IP encapsulation
Ethernet switching fabric

RoCEv2 transports RDMA communication over UDP/IP, allowing operation across appropriately engineered Layer 3 Ethernet infrastructure.

INFINIBAND
GPU application buffers
InfiniBand transport
InfiniBand link and routing architecture
InfiniBand switching fabric

InfiniBand provides a specialised high-performance fabric architecture with its own transport, management, routing and link-level mechanisms.

Characteristic Ethernet / RoCEv2 InfiniBand
Network architecture Ethernet and IP-based fabric. Native InfiniBand fabric.
RDMA transport RoCEv2 over UDP/IP. Native InfiniBand transport.
Fabric management Ethernet/IP control and management mechanisms. Subnet management and InfiniBand-specific tools.
Congestion behaviour ECN, endpoint congestion control, PFC where required, and platform-specific mechanisms. Credit-based link flow control and supported fabric congestion mechanisms.
Path selection ECMP and supported adaptive routing or load-balancing mechanisms. Subnet routing and supported adaptive routing capabilities.
Operational considerations Ethernet interoperability, QoS, congestion and IP fabric design. Fabric management, partitioning, routing and link-level performance.
AI-OPTIMISED ETHERNET

NVIDIA Spectrum-X and BlueField SuperNIC architecture

Spectrum-X is NVIDIA's Ethernet networking platform designed for demanding AI workloads. It combines compatible switching, endpoint networking and software capabilities to improve distributed AI communication.

Spectrum-X architectures can incorporate BlueField-3 SuperNIC endpoints alongside compatible Spectrum switches.

The SuperNIC designation emphasises accelerated AI networking. It should not be assumed that every BlueField DPU deployment provides the same product configuration, operational mode or Spectrum-X feature set.

SPECTRUM-X — CONCEPTUAL ENDPOINT AND FABRIC COORDINATION
AI ENDPOINT A AI ENDPOINT B GPU COMPUTE GPU COMPUTE BLUEFIELD SuperNIC BLUEFIELD SuperNIC RDMA networking Endpoint congestion control Supported packet processing RDMA networking Endpoint congestion control Supported packet processing HOST CONTROL SOFTWARE HOST CONTROL SOFTWARE SPECTRUM SWITCH FABRIC FABRIC PATH A FABRIC PATH B FABRIC PATH C Coordinated endpoint and fabric capabilities Logical paths, not a product-specific forwarding pipeline
Conceptual Spectrum-X architecture. Supported adaptive routing, congestion control, packet ordering and telemetry capabilities depend on the endpoint, switch generation, software and configuration.
AR

Adaptive routing

Supported fabric mechanisms can use network conditions to improve path utilisation for demanding AI traffic.

CC

Congestion control

Endpoint and fabric mechanisms help regulate traffic during contention and congestion.

ORD

Packet ordering

Compatible endpoint capabilities can address ordering requirements associated with supported multipath forwarding.

OBS

Fabric visibility

Network telemetry helps identify congestion, uneven path utilisation and infrastructure performance problems.

ISO

Workload isolation

Supported networking and infrastructure policies help limit interference between concurrent workloads.

RDMA

Accelerated communication

Compatible endpoint data paths support efficient RDMA communication for distributed accelerator workloads.

AI DATA CENTRE TOPOLOGY

Leaf-spine architecture and east-west AI traffic

Distributed AI workloads frequently generate substantial east-west traffic between participating compute nodes.

Leaf-spine architectures provide multiple potential paths between server-facing switches and can be designed to support substantial aggregate network capacity.

AI LEAF-SPINE FABRIC — PARALLEL COMPUTE FLOWS
SPINE 01 SPINE 02 LEAF 01 LEAF 02 LEAF 03 LEAF 04 RDMA ADAPTER RDMA ADAPTER RDMA ADAPTER RDMA ADAPTER GPU GPU GPU GPU GPU GPU GPU GPU Multiple potential paths for east-west GPU communication
Simplified leaf-spine topology with illustrative parallel communication paths. Actual path selection depends on routing, load balancing, transport and fabric capabilities. Server attachment redundancy is omitted from this diagram for clarity.

Understanding fabric oversubscription

Oversubscription describes the relationship between aggregate downstream connectivity and available upstream network capacity.

LEAF SWITCH OVERSUBSCRIPTION
Oversubscription = Downlink Capacity / Uplink Capacity

Example: 32 × 400 Gb/s downlinks and 16 × 400 Gb/s uplinks = 2:1.

A 2:1 design cannot carry the theoretical maximum simultaneous downstream traffic through its uplinks without contention.

AI fabrics often require careful attention to bisection bandwidth, topology symmetry, collective communication patterns and oversubscription across failure conditions.

NETWORK PERFORMANCE ENGINEERING

Why congestion matters in distributed AI training

AI communication workloads can produce large synchronised bursts of traffic between participating accelerator resources.

When multiple flows converge on a network output interface, the aggregate arrival rate may temporarily exceed the available transmission capacity.

Queue occupancy increases, adding latency and potentially triggering congestion signalling, flow control or packet loss.

AI NETWORK INC AST — CONVERGING GPU FLOWS
GPU SENDER 01 GPU SENDER 02 GPU SENDER 03 GPU SENDER 04 SWITCH OUTPUT QUEUE ARRIVAL RATE > SERVICE RATE Queueing delay and congestion signalling GPU RECEIVER Shared destination BOTTLENECK Multiple simultaneous senders converge on one output
Conceptual incast congestion scenario. Queue thresholds and signalling behaviour depend on switch architecture, traffic class, buffer configuration and congestion policy.
ECN

Explicit Congestion Notification

Compatible network devices can mark congestion instead of relying exclusively on packet loss to communicate contention.

CNP

Congestion Notification Packets

Supported RoCE congestion-control mechanisms can communicate congestion information back toward transmitting endpoints.

PFC

Priority Flow Control

Where deployed, PFC can pause selected Ethernet priorities to reduce packet loss during buffer pressure.

AR

Adaptive path selection

Supported fabric mechanisms can distribute traffic across alternative paths according to available capabilities.

RATE

Endpoint rate regulation

Congestion-control algorithms can adjust transmission behaviour in response to applicable network feedback.

QoS

Traffic classification

Appropriate traffic classes and scheduling policies help manage competing communication requirements.

PFC DOES NOT SOLVE CONGESTION BY ITSELF

Priority Flow Control can reduce selected packet-loss conditions, but excessive pause propagation may introduce head-of-line blocking, congestion spreading and operational complexity. PFC requirements vary across supported RoCE deployments. Congestion control must be engineered as an end-to-end system.

DPU INFRASTRUCTURE ACCELERATION

What BlueField actually offloads in AI infrastructure

A GPU cluster requires much more than accelerator-to-accelerator communication. Every compute node also participates in infrastructure networking, storage access, management and security operations.

BlueField can provide a dedicated execution environment for selected infrastructure services and accelerate eligible data-path operations through supported hardware and software capabilities.

AI NODE — SEPARATION OF PROCESSING RESPONSIBILITIES
HOST CPU GPU BLUEFIELD DPU APPLICATION ORCHESTRATION OPERATING SYSTEM DATA PREPARATION RUNTIME CONTROL TENSOR COMPUTATION FORWARD PASS BACKWARD PASS MODEL EXECUTION VIRTUAL NETWORKING STORAGE SERVICES SECURITY ENFORCEMENT INFRASTRUCTURE CONTROL Complementary processing domains within an AI compute platform
Illustrative responsibility separation. Actual CPU, GPU, NIC and DPU processing depends on workload design and supported offload capabilities.

Virtual networking

Accelerate supported virtual switching, flow steering, tunnelling and tenant connectivity operations.

Storage infrastructure

Support compatible storage virtualisation and accelerated access to remote storage resources.

Infrastructure security

Enforce supported network and infrastructure security policies outside ordinary application execution.

Infrastructure isolation

Separate selected management and infrastructure services from tenant application environments.

Network telemetry

Provide supported counters and infrastructure observations for operational monitoring.

Host resource efficiency

Reduce selected host processing responsibilities where supported offloads are active and effective.

AI PERFORMANCE ECONOMICS

Communication overhead and GPU utilisation

Expensive accelerator resources create value when they execute useful computational work.

Distributed workloads can experience periods of reduced computational activity while waiting for communication, data loading, synchronisation or infrastructure services.

Reducing exposed communication and infrastructure delays can improve the efficiency of a distributed workload. However, the benefit depends on the application bottleneck and the extent to which computation overlaps communication.

TRAINING ITERATION — HYPOTHETICAL TIME BUDGET
Baseline training iteration 100 ms
Example optimised iteration 80 ms
Useful computation Exposed communication Other overhead
BASELINE COMPUTE FRACTION 60%

60 ms of computation in 100 ms.

OPTIMISED COMPUTE FRACTION 75%

60 ms of computation in 80 ms.

ITERATION RATE INCREASE 25%

For the same work per iteration.

Synthetic educational example, not a BlueField or Spectrum-X benchmark. Compute fraction is a simplified time-budget metric and is not equivalent to measured GPU hardware utilisation.
SIMPLIFIED ITERATION SPEEDUP
Speedup = Baseline Time / Optimised Time

100 ms / 80 ms = 1.25×

This example demonstrates why reducing non-computational delays can increase application throughput even when the accelerator hardware performs the same amount of mathematical work.

The most valuable infrastructure optimisation is not necessarily the one that produces the highest network benchmark. It is the one that reduces the application's actual performance bottleneck.
COMMUNICATION CAPACITY PLANNING

Understanding network bandwidth and transfer time

Network link rates are commonly expressed in bits per second, while GPU buffers and application datasets are commonly expressed in bytes.

Engineers must account for this distinction when estimating theoretical data-transfer times.

THEORETICAL TRANSFER — 1 GB DECIMAL BUFFER
100 Gb/s LINK 80 ms

Ideal serialisation time.

200 Gb/s LINK 40 ms

Ideal serialisation time.

400 Gb/s LINK 20 ms

Ideal serialisation time.

Theoretical one-direction transfer times for 1,000,000,000 bytes at the specified nominal bit rates. Actual transfer times include applicable overhead, congestion, processing and scheduling.
THEORETICAL TRANSFER TIME
Time = Data Size in Bits / Link Rate

8,000,000,000 bits / 400,000,000,000 bits/s = 0.02 seconds.

Increasing link bandwidth does not guarantee a proportional improvement in distributed training performance.

PCIe capacity, GPU memory access, network congestion, collective algorithms and computational dependencies may limit the improvement achieved by faster links.

END-TO-END AI WORKLOAD

Following a distributed training iteration

Consider a data-parallel training workload operating across multiple GPU compute nodes. Each iteration involves computational, communication and infrastructure activities.

01

Retrieve training data

Data pipelines obtain the required training samples from local or remote storage. Supported BlueField storage services may participate in this path.

02

Prepare and distribute input data

Host-side or accelerated data processing prepares training samples and makes them available to the appropriate GPUs.

03

Execute the forward pass

GPU computational resources process model inputs and calculate intermediate activations and outputs.

04

Calculate gradients

Backpropagation computes gradients associated with model parameters.

05

Initiate collective communication

The distributed runtime invokes applicable communication operations, potentially overlapping them with ongoing GPU computation.

06

Transfer GPU-resident data

Supported GPUDirect RDMA paths can transfer eligible GPU memory buffers through compatible network adapters.

07

Transport data across the AI fabric

Ethernet or InfiniBand infrastructure forwards collective communication traffic between participating endpoints.

08

Complete synchronisation and update model state

The runtime completes the required collective operations and performs applicable optimiser updates.

09

Continue training and checkpoint periodically

Subsequent iterations proceed while infrastructure services continue providing networking, storage, security and management functions.

TRAINING IS NOT ALWAYS A SERIAL PIPELINE

Modern training frameworks can overlap computation, communication, input loading and other operations. The sequence above explains logical responsibilities rather than prescribing an exact execution schedule.

AI MODEL SERVING

BlueField in distributed AI inference environments

AI inference infrastructure has different performance objectives from many training environments.

Model serving systems must process incoming requests while managing latency, throughput, accelerator memory and workload scheduling.

Distributed inference can involve multiple GPUs, expert routing, tensor parallelism and communication between separate processing stages.

AI INFERENCE — INFRASTRUCTURE AND MODEL EXECUTION
APPLICATION REQUESTS AI GATEWAY / SERVING CONTROL Request routing / admission / scheduling INFRASTRUCTURE NETWORKING DOMAIN Supported BlueField networking and security services MODEL SERVING WORKER A MODEL SERVING WORKER B GPU 0 GPU 1 GPU 2 GPU 3 MODEL / KV CACHE MODEL / KV CACHE MODEL / KV CACHE MODEL / KV CACHE Logical request and infrastructure processing domains
Conceptual inference service architecture. Application request routing, model scheduling and KV-cache management remain serving software responsibilities unless explicitly supported by an integrated acceleration solution.

Time to first token

Measures the time until a streaming model response produces its first token. Queueing, prefill and infrastructure delays can influence this metric.

Inter-token latency

Measures the timing between generated tokens. Distributed model communication can contribute to decoding latency.

Serving throughput

Measures completed requests or generated tokens over time for a defined workload and service-level objective.

MULTI-TENANT AI INFRASTRUCTURE

Security isolation in shared GPU environments

Enterprise AI infrastructure increasingly serves multiple applications, development teams and organisational tenants.

Shared accelerator infrastructure introduces requirements for network isolation, storage authorisation, management-plane protection and workload lifecycle control.

BlueField can contribute to a dedicated infrastructure trust boundary through supported operating modes, security capabilities and management configurations.

NET

Tenant network isolation

Apply supported segmentation and forwarding policies to separate tenant communication domains.

SEC

Infrastructure enforcement

Execute supported security policies within the infrastructure processing domain rather than relying solely on tenant-controlled host software.

STOR

Storage authorisation

Associate workloads with appropriate storage resources and protect infrastructure storage mappings.

MGMT

Management separation

Restrict infrastructure configuration and administrative access according to the selected trust model.

DMA

Memory access protection

Configure applicable platform and device protections for DMA and peer-memory access.

AUDIT

Infrastructure accountability

Correlate policy configuration, operational evidence and administrative events across the infrastructure.

DPU ISOLATION IS NOT GPU COMPUTE ISOLATION

BlueField infrastructure isolation does not automatically isolate GPU execution or accelerator memory between tenants. GPU partitioning, virtualisation, supported MIG configurations, scheduling and platform security controls address additional accelerator-specific isolation requirements.

AI INFRASTRUCTURE INVESTIGATION

Investigating slow distributed AI training

Reduced training throughput can originate from accelerator computation, memory pressure, network communication, storage access or infrastructure processing.

A GPU utilisation metric alone is insufficient to determine the root cause. Engineers must correlate evidence across the complete distributed system.

INCIDENT TELEMETRY — COLLECTIVE COMMUNICATION DEGRADATION
HIGH MEDIUM LOW BASELINE ONSET DEGRADED TRAINING RECOVERY VALIDATION Collective duration Network congestion Useful GPU computation activity
Synthetic normalised telemetry. Correlation between congestion, collective duration and GPU activity supports a network-related investigation but does not independently prove root cause.

GPU and platform investigation

AI COMPUTE NODE — GPU AND PCIe EVIDENCE
# Inspect discovered GPUs and driver state
nvidia-smi

# Inspect GPU and adapter topology
nvidia-smi topo -m

# Observe available GPU activity metrics
nvidia-smi dmon

# Inspect detailed GPU information
nvidia-smi -q

# Inspect supported NVLink status
nvidia-smi nvlink --status

# Inspect PCIe device topology
lspci -tv

# Inspect device and driver bindings
lspci -nnk

# Investigate GPU and PCIe kernel events
journalctl -k | grep -Ei 'nvrm|xid|pcie|aer'
Example NVIDIA and Linux inspection commands. Supported output and metrics depend on GPU generation, installed drivers and platform configuration.

Network and RDMA investigation

NETWORK ENDPOINT — RDMA AND FABRIC EVIDENCE
# Inspect RDMA device information
ibv_devinfo

# Inspect RDMA link state
rdma link show

# Inspect active RDMA resources
rdma resource show

# Inspect available RDMA statistics
rdma statistic show

# Inspect Ethernet interface counters
ip -s link

# Inspect driver-specific network counters
ethtool -S INTERFACE

# Inspect network device information
devlink dev info

# Inspect InfiniBand port state where applicable
ibstat
Generic diagnostic examples for compatible environments. Replace INTERFACE with the actual device name. Counter names and supported statistics vary by adapter, firmware and software release.

Collective communication diagnostics

NCCL — CONTROLLED DIAGNOSTIC RUN
# Enable NCCL informational diagnostics
export NCCL_DEBUG=INFO

# Select relevant diagnostic subsystems
export NCCL_DEBUG_SUBSYS=INIT,NET,GRAPH

# Example single-node collective test
# Requires a compatible nccl-tests build
# and four available GPUs.
./build/all_reduce_perf -b 8M -e 256M -f 2 -g 4

# Remove diagnostic settings afterwards
unset NCCL_DEBUG
unset NCCL_DEBUG_SUBSYS
The collective test generates GPU and communication load. Run only in an authorised test allocation. A single-node test does not validate the scale-out network; multi-node testing requires appropriate process launching, rank placement and network configuration.
PRODUCTION ENGINEERING

AI fabric and BlueField troubleshooting matrix

Observed symptom Possible cause Evidence to investigate
Low GPU computation activity Communication delays, input starvation, synchronisation or application imbalance. GPU timelines, data-loader metrics, collective duration and storage latency.
Slow multi-node AllReduce Fabric congestion, topology limitations or inefficient communication configuration. NCCL diagnostics, network counters, rank placement and collective tests.
Unexpected host-memory traffic GPU data staging or unavailable direct peer-memory communication. GPU/adapter topology, runtime logs and supported memory-access configuration.
High network queue occupancy Incast, oversubscription or uneven traffic distribution. Switch queue telemetry, ECN counters and per-link utilisation.
Excessive PFC pause activity Sustained congestion, buffer pressure or unsuitable flow-control configuration. Per-priority pause counters, queue state and congestion timelines.
Uneven fabric path utilisation Flow hashing imbalance, topology asymmetry or path failure. Per-link throughput, routing state and supported adaptive routing telemetry.
RDMA communication failure Incompatible configuration, link failure or transport resource problem. RDMA device state, connection logs, addressing and transport counters.
High DPU Arm utilisation Infrastructure workload pressure, polling or software-path processing. Per-core utilisation, service metrics and hardware offload evidence.
Training slows during checkpointing Storage contention, network sharing or checkpoint synchronisation. Storage throughput, I/O latency and training iteration timelines.
Unexpected tenant interference Shared resource contention or incomplete isolation policies. Traffic classification, resource allocation and infrastructure policies.
Inference latency increases Serving queue pressure, GPU memory constraints or distributed communication. Time to first token, inter-token latency, batch state and network metrics.
Training stalls after link failure Transport recovery failure or collective communication timeout. Fabric events, endpoint state, runtime logs and recovery behaviour.
AI FACTORY DESIGN PRINCIPLES

Engineering BlueField-enabled AI infrastructure

01

Start with the workload

Understand model parallelism, collective operations, message sizes and application performance objectives before selecting infrastructure components.

02

Map communication domains

Distinguish scale-up GPU communication, scale-out compute networking, storage traffic and infrastructure management.

03

Validate physical topology

Confirm GPU-to-adapter connectivity, PCIe resources, supported peer-memory access and fabric attachment.

04

Engineer congestion behaviour

Validate queue management, congestion signalling, endpoint response and traffic isolation under realistic workloads.

05

Verify infrastructure offloads

Establish which networking, storage and security operations are actually accelerated rather than assuming hardware presence guarantees offload.

06

Measure application outcomes

Evaluate training iteration time, collective duration, useful accelerator activity and inference service objectives.

ENGINEERING TAKEAWAY

BlueField as an infrastructure processor for the AI factory

NVIDIA BlueField extends accelerated infrastructure beyond conventional network connectivity by providing programmable infrastructure processing and supported hardware acceleration.

Within AI environments, GPUs execute accelerated computational workloads, NVLink and NVSwitch support compatible scale-up communication, and high-performance Ethernet or InfiniBand fabrics provide scale-out connectivity.

GPUDirect RDMA can reduce intermediate data movement for supported GPU communication paths, while BlueField can accelerate selected infrastructure networking, storage and security responsibilities.

The effectiveness of this architecture depends on how these technologies are integrated, configured and operated as a complete distributed system.

The architectural objective is not simply to connect more GPUs. It is to create an infrastructure platform in which accelerated computation, communication, storage and security operate together with minimal unnecessary interference.
NETWORK INSIGHT — ENGINEERING GUIDES BLUEFIELD DPU / SECTION 07
Network Insight / Interactive Engineering 07

Inside the Accelerated AI Supercomputing Fabric

Investigate the relationship between GPU memory, PCIe topology, GPUDirect RDMA, BlueField infrastructure services and high-speed Ethernet networking. Discover why distributed AI training performance depends on the entire communication architecture.

AI SUPERCOMPUTING FABRIC BLUEFIELD GPUDIRECT RDMA ROCEv2 SPECTRUM-X CONCEPTS COLLECTIVE COMMUNICATION
01 / Distributed AI engineering scenarios

Select an AI infrastructure workload

02 / AI fabric control centre

Configure the communication path

03 / AI cluster digital model
FABRIC READY
DISTRIBUTED AI COMPUTE DOMAIN HIGH-SPEED ETHERNET AI FABRIC 400 Gb/s per server / RoCEv2 FABRIC TELEMETRY NORMAL QUEUE PRESSURE Conceptual four-server AI cluster / one modelled network endpoint per server
Execute a GPU transfer to inspect the communication architecture.
Effective bandwidth
0

GB/s per endpoint

Collective time
0

ms

Compute fraction
0%

Modelled iteration

Host CPU demand
0

Illustrative units

All performance values are illustrative. This laboratory does not reproduce measured NVIDIA hardware or NCCL benchmark results.

04 / GPU memory data movement

Inspect the active GPU communication path

GPUDirect RDMA

A compatible RDMA-capable network adapter can access registered GPU memory without staging the application payload through host memory. Appropriate drivers, memory registration and platform topology are required.

Host-staged communication

GPU data is copied into host-accessible memory before network transmission. The receiving system subsequently copies the data into destination GPU memory. These additional transfers consume memory and interconnect resources.

05 / Ring collective communication

Four-endpoint AllReduce visualiser

LOGICAL COLLECTIVE READY Round 0 / 6
Three reduce-scatter rounds followed by three all-gather rounds.

Four server-level participants are used to illustrate an inter-server collective. The sixteen displayed GPUs are not modelled as sixteen independent collective ranks.

06 / Infrastructure evidence console

Inspect communication diagnostics

Console messages are synthetic diagnostic evidence, not output from actual NVIDIA DOCA, NCCL or network management commands.

07 / AI training performance investigation

Where does the distributed iteration spend its time?

GPU computation 120 ms
Computation Communication

Communication resource ceilings

08 / Controlled architecture comparison

Separate GPU data movement from DPU offloading

Compare four infrastructure configurations using identical workload and network settings. Observe that GPUDirect RDMA and DPU infrastructure offloading address different processing problems.

ARCHITECTURE BANDWIDTH COLLECTIVE HOST DEMAND
GPUDirect RDMA primarily changes the application payload movement path. BlueField offloading can reduce selected host infrastructure processing demands. Enabling a DPU does not automatically enable GPUDirect RDMA or accelerate every GPU collective.
09 / AI infrastructure fault injection

Introduce a distributed AI communication problem

No fault injected.
10 / Production AI infrastructure incident

Incident 007 — The stalled GPU training cluster

A sixteen-GPU AI environment is spending excessive time synchronising model gradients. The engineering team suspects that a recent infrastructure change has degraded the inter-server communication path.

Restore direct GPU memory communication, correct the infrastructure configuration, remove fabric congestion and achieve at least 20 GB/s of modelled endpoint bandwidth. Verify your repair with a GPU transfer and a completed ring collective.

○ Restore the GPUDirect RDMA path.
○ Restore BlueField infrastructure offloading.
○ Restore healthy fabric and congestion response.
○ Achieve at least 20 GB/s modelled bandwidth.
○ Verify successful GPU-to-GPU data movement.
○ Complete all six collective rounds.
Load the incident to begin your investigation.
11 / Engineering interpretation

Understanding accelerated AI infrastructure

GPU compute versus infrastructure processing

GPUs execute model computation. DPUs can handle selected infrastructure networking, security and storage services. These are complementary processing domains, rather than interchangeable processors.

GPUDirect RDMA prerequisites

Direct access to GPU memory depends on supported devices, software, registration mechanisms and PCIe topology. Hardware availability alone does not guarantee an operational direct path.

Collective communication

AllReduce combines data from multiple participants and distributes the result. Ring algorithms divide this process into reduce-scatter and all-gather phases. Real NCCL deployments can select different algorithms and communication channels.

RoCEv2 and congestion management

RoCEv2 carries RDMA traffic over routable IP networks using UDP. ECN marking and endpoint congestion response can help manage congestion. PFC may also be used in appropriately engineered lossless Ethernet designs.

Spectrum-X architecture

NVIDIA Spectrum-X combines Ethernet switching, supported SuperNICs and coordinated software capabilities for AI networking. Adaptive routing and congestion management depend on the deployed platform and configuration.

AI infrastructure bottlenecks

Network capacity, PCIe topology, memory movement, collective scheduling and contention can all influence distributed training performance. A faster network cannot eliminate every compute or communication bottleneck.

View performance model assumptions

The model represents four server-level collective participants. Each server contains four GPUs, with local aggregation assumed to have already occurred.

Effective communication bandwidth is the minimum of network payload capacity, PCIe capacity and an illustrative memory-movement ceiling.

Network payload efficiency is assumed to be 90%. Congestion multipliers range from 0.25 to 1.0. Configured congestion response improves selected modelled contention conditions but does not eliminate congestion.

Direct GPU memory movement has an illustrative ceiling of 80 GB/s. Host-staged movement has an illustrative ceiling of 12 GB/s. These are teaching assumptions, not measured hardware limits.

Ring AllReduce communication volume per participant is modelled as 2 × (N − 1) / N × buffer size, where N equals four.

Collective time is estimated from communication volume divided by effective bandwidth, plus six illustrative communication startup delays.

Iteration time equals computation time plus collective communication time. Compute and communication overlap, intra-server NVLink traffic, GPU kernel scheduling and real NCCL algorithms are not simulated.

Host CPU demand is expressed in arbitrary units. It is not measured CPU utilisation. DPU offloading changes the infrastructure processing component independently of the GPU payload transfer mode.

BlueField-3 is the DPU architectural reference. The illustrated Ethernet fabric is conceptual, not a certified Spectrum-X reference deployment. Supported combinations of BlueField devices, SuperNICs, switches, GPUs and software must be validated against product documentation.

NVIDIA DOCA Documentation | GPUDirect RDMA Documentation
NETWORK INSIGHT
Engineering Guide 06 / AI Supercomputing Fabric
NETWORK INSIGHT ENGINEERING KNOWLEDGE SERIES
SILICON OFFLOAD EDITION
08 / Cloud-Native Infrastructure Engineering

Beyond the Kubernetes Node
Cloud-Native and Kubernetes Integration

The emergence of the Data Processing Unit introduces a new infrastructure execution domain within cloud-native platforms. Networking, security, storage and infrastructure services can operate independently of application workloads, while Kubernetes provides a declarative mechanism for managing the desired infrastructure state.

DPU Platform Framework DPU Operator DPUService Kubernetes CNI SR-IOV OVS Offload Multi-Tenant Isolation Declarative Infrastructure
KUBERNETES DPU INFRASTRUCTURE ARCHITECTURE
Kubernetes management, host application workloads, DPU infrastructure services and hardware packet processing KUBERNETES MANAGEMENT PLANE Kubernetes API Desired infrastructure state DPF Operator Controller reconciliation DPU Resources Provisioning and configuration DPUService Infrastructure applications HOST WORKLOAD DOMAIN Application Pod A Tenant A workload Application Pod B Tenant B workload Kubelet / Container Runtime / CNI Workload networking and resource allocation HOST CPU / PCIe PF / VF / SF interfaces DPU INFRASTRUCTURE DOMAIN Network Service Security Service Storage Service DPU Kubernetes Runtime / Arm Linux Infrastructure pods and control applications BLUEFIELD HARDWARE ConnectX / e-switch / acceleration engines PCIe DATA CENTRE NETWORK FABRIC
Management and reconciliation Host workload networking DPU infrastructure processing Separate tenant workload
Figure 8.1 — Conceptual BlueField-enabled Kubernetes architecture. The management, host workload and DPU infrastructure domains have distinct responsibilities. Exact cluster boundaries, service placement and interface configuration depend on the deployed DPU Platform Framework architecture.
01 / Infrastructure Evolution

Why Kubernetes Infrastructure Is Moving Towards DPUs

A conventional Kubernetes worker node combines application execution with a substantial collection of infrastructure responsibilities. The host CPU runs containers, processes network traffic, maintains virtual networking state, enforces security policies and supports storage operations.

As application density increases, infrastructure processing can compete with application workloads for CPU cycles, memory bandwidth, cache capacity and scheduling resources. This becomes particularly significant in high-throughput networking environments, distributed storage platforms and GPU-intensive AI clusters.

BlueField introduces a separate infrastructure execution environment. Selected infrastructure services can execute on the DPU's embedded Arm processors, while supported packet-processing operations are programmed into its hardware acceleration engines.

CONVENTIONAL HOST-CENTRIC NODE
ApplicationHost CPU
Virtual SwitchHost CPU
SecurityHost CPU
StorageHost CPU
HOST CPU Shared infrastructure and application resources
DPU-ENABLED NODE
Application AHost CPU
Application BHost CPU
NetworkingDPU domain
Security / StorageDPU domain
BLUEFIELD DPU Dedicated infrastructure execution environment

Engineering principle: A DPU does not replace Kubernetes or the host CPU. It changes where selected infrastructure functions execute and where supported forwarding operations are accelerated.

02 / Declarative Infrastructure

NVIDIA DPU Platform Framework and the DPU Operator

NVIDIA's DPU Platform Framework, commonly referred to as DPF, provides a Kubernetes-oriented architecture for provisioning, configuring and managing BlueField DPUs and the infrastructure services that operate on them.

Rather than configuring every DPU independently through manual installation procedures, operators describe the required infrastructure state through Kubernetes resources. Controllers observe those resources and reconcile the actual infrastructure towards the desired configuration.

01 — DESIRED STATE

Kubernetes API

Stores infrastructure resource specifications, configuration and controller-reported status.

02 — RECONCILIATION

DPF Operator

Coordinates framework components and lifecycle management through Kubernetes controller mechanisms.

03 — PROVISIONING

DPU Lifecycle

Supports DPU discovery, provisioning, software image deployment and infrastructure configuration.

04 — SERVICE DELIVERY

Infrastructure Services

Deploys and manages supported infrastructure applications within the DPU execution environment.

DECLARATIVE RECONCILIATION LOOP
CONTROLLER Reconcile Desired State Kubernetes resource Compare and Plan Identify required changes Actual State DPU and service status Observe and Report Conditions and readiness
Figure 8.2 — Controllers repeatedly compare desired and observed state. Reconciliation is asynchronous and must accommodate dependencies, retries, failures and partially completed operations.
03 / Kubernetes Resource Architecture

DPF Custom Resources and Infrastructure Lifecycle

Kubernetes custom resources extend the native API with infrastructure-specific objects. DPF uses custom resources to represent DPU provisioning requirements, software configurations, infrastructure services and their deployment relationships.

RESOURCE CONCEPT ENGINEERING RESPONSIBILITY OPERATIONAL EVIDENCE
DPU Represents an individual DPU and its lifecycle state. Provisioning status and readiness conditions.
DPUSet Defines provisioning requirements for a selected group of DPUs. Resource creation and rollout progress.
DPUFlavor Describes DPU configuration requirements. Configuration compatibility and application status.
BFB Represents a BlueField boot or installation image resource. Image availability and provisioning results.
DPUService Defines an infrastructure service deployment on DPU-side infrastructure. Service reconciliation and workload health.
DPUDeployment Coordinates DPU provisioning and associated infrastructure service deployment. Deployment conditions and dependency readiness.
DPUServiceChain Describes supported infrastructure service connectivity and chaining. Service interfaces and forwarding configuration.
Resource availability, API groups, schema fields and controller responsibilities are release-dependent. The table describes architectural roles rather than a complete API specification.
04 / Infrastructure Service Orchestration

DPUService Architecture and Infrastructure Pods

DPUService provides a declarative mechanism for deploying infrastructure applications into the DPU-side Kubernetes environment. Depending on the service architecture, these applications can configure networking, establish service connectivity, program hardware forwarding rules or expose infrastructure capabilities to host workloads.

Infrastructure pods are conceptually different from application pods. Application pods deliver business functionality. Infrastructure pods deliver the networking, security, storage and management capabilities required by the application environment.

INFRASTRUCTURE SERVICE EXECUTION STACK
DPUService Resource Declarative service configuration Service Deployment Controller Resolve and reconcile service deployment DPU INFRASTRUCTURE PODS Virtual Networking Security Policy Storage Service Telemetry Embedded Arm Linux / Runtime / Drivers / DOCA APIs ConnectX Hardware / Embedded Switch / Supported Acceleration Engines
Figure 8.3 — Infrastructure applications can use software interfaces to configure supported hardware capabilities. Running a service on the Arm subsystem does not automatically mean that all of its processing is hardware-offloaded.

Important distinction: DPU-resident infrastructure software and hardware-accelerated packet processing are separate execution mechanisms. A service may use both, depending on its implementation.

05 / Workload Connectivity

Kubernetes CNI Integration and SR-IOV

The Container Network Interface, or CNI, defines how container runtimes invoke network plugins to configure workload connectivity. In a conventional Kubernetes environment, this frequently involves virtual Ethernet interfaces, Linux routing, bridges, virtual switches or eBPF-based networking.

BlueField-enabled environments can integrate with supported CNI architectures to provide connectivity through hardware-backed interfaces and DPU-managed forwarding paths.

Single Root I/O Virtualization, or SR-IOV, allows a PCIe device to expose multiple Virtual Functions. Kubernetes device plugins can advertise those resources, while an appropriate network attachment and CNI configuration assigns an available interface to a pod.

SR-IOV WORKLOAD ATTACHMENT ARCHITECTURE
KUBERNETES WORKER NODE Application Pod A Secondary network interface Application Pod B Secondary network interface CNI / Device Plugin Allocation and configuration VF 0 VF 1 BLUEFIELD DPU VF 0 Representor VF 1 Representor Policy / Flow Control HARDWARE EMBEDDED SWITCH PHYSICAL NETWORK UPLINK
Figure 8.4 — Conceptual SR-IOV attachment and embedded switch architecture. Representors provide software control and visibility into represented switch ports; hardware-offloaded traffic need not traverse the representor software interface.
RESOURCE ALLOCATION

Device Plugin

Advertises supported hardware resources to Kubernetes and participates in allocating devices to workloads.

NETWORK ATTACHMENT

Multus and CNI

Multus can coordinate additional network attachments through delegated CNI plugins, including supported SR-IOV configurations.

HARDWARE CONNECTIVITY

Virtual Function

Provides a hardware-backed interface that can reduce dependence on conventional host software forwarding paths.

SWITCH CONTROL

Representor

Exposes a software representation of a hardware switch port for supported configuration, policy and monitoring.

06 / Accelerated Data Plane

Hardware-Offloaded Virtual Switching

Virtual switching provides the connectivity and forwarding abstraction required by many cloud-native networking architectures. Open vSwitch is one example of a software switching platform that can integrate with supported hardware-offload mechanisms.

In a BlueField deployment, supported virtual switching rules can be translated into hardware match-and-action entries. The DPU's embedded switch then processes eligible traffic without requiring the complete software switching path to execute for every packet.

VIRTUAL SWITCH CONTROL AND HARDWARE FORWARDING
SOFTWARE CONTROL DOMAIN Network Controller OVS / Policy Application Driver / Offload Interface HARDWARE FAST PATH Ingress Interface Packet Classification Flow Table Match Policy Action Egress Forwarding Program supported match/action rules
Figure 8.5 — Software establishes forwarding intent. Supported hardware rules process eligible packets. Unsupported actions, exceptions and resource exhaustion may require software processing or result in failed offload installation, depending on configuration.
NETWORK FUNCTION SOFTWARE RESPONSIBILITY POTENTIAL HARDWARE ROLE
Virtual switching Maintain logical connectivity and forwarding intent. Match and forward eligible traffic.
Traffic classification Define packet matching criteria. Parse headers and match supported fields.
Overlay networking Configure tunnels and endpoint mappings. Supported encapsulation and decapsulation.
Security policy Translate policy into enforceable rules. Supported filtering and forwarding actions.
Telemetry Collect, correlate and interpret statistics. Hardware counters and supported measurements.
07 / Infrastructure Security

Multi-Tenant Isolation and Independent Trust Domains

Multi-tenant Kubernetes platforms must prevent one workload or tenant from accessing another tenant's resources without authorisation. Kubernetes namespaces provide administrative organisation, but namespace separation alone does not guarantee network isolation.

DPU-based infrastructure can introduce an additional enforcement boundary by placing selected networking and security functions outside the host application execution environment.

MULTI-TENANT HARDWARE POLICY ENFORCEMENT
TENANT A Application A Network identity A TENANT B Application B Network identity B SHARED SERVICES Approved Service Explicit access policy DPU POLICY ENFORCEMENT DOMAIN A → Shared Service: ALLOW A → B: DENY B → Shared Service: ALLOW SHARED PHYSICAL NETWORK INFRASTRUCTURE
Figure 8.6 — Illustrative tenant isolation policy. Enforcement requires supported network identity mappings, explicit policy configuration and validated forwarding paths. A DPU does not automatically establish tenant isolation.
ISOLATION LAYER 01

Kubernetes Identity

Namespaces, workload labels, service accounts and network policy selectors establish application context and administrative intent.

ISOLATION LAYER 02

Network Segmentation

VLANs, overlays, logical interfaces and routing domains can separate tenant forwarding environments.

ISOLATION LAYER 03

Hardware Enforcement

Supported DPU flow rules can enforce selected filtering, forwarding and segmentation decisions.

ISOLATION LAYER 04

Management Trust

Restricted administrative access, trusted software, secure provisioning and controlled management interfaces protect the infrastructure execution domain.

Security engineering consideration: Kubernetes NetworkPolicy enforcement depends on the network implementation. Secondary SR-IOV interfaces and hardware-bypassed forwarding paths must be evaluated explicitly. Do not assume that policy applied to the primary pod network automatically protects every additional interface.

08 / Operational Lifecycle

Declarative DPU Provisioning and Service Deployment

Managing a fleet of DPUs introduces additional lifecycle dependencies beyond those found in conventional Kubernetes worker nodes. The DPU must be discovered, provisioned, configured and made operational before dependent infrastructure services can become available.

STAGE 01

Discover

Identify eligible BlueField devices, host associations and supported hardware capabilities.

STAGE 02

Declare

Define required software images, DPU configurations and infrastructure service specifications.

STAGE 03

Provision

Install or configure the required DPU software environment through supported provisioning workflows.

STAGE 04

Register

Establish the required DPU-side runtime and infrastructure management connectivity.

STAGE 05

Deploy

Reconcile infrastructure services and their configuration dependencies.

STAGE 06

Program

Configure service interfaces, forwarding state and supported hardware acceleration rules.

STAGE 07

Validate

Verify service readiness, workload connectivity, isolation and actual hardware forwarding.

STAGE 08

Maintain

Monitor drift, reconcile changes and coordinate controlled upgrades or recovery operations.

Production requirement: Infrastructure upgrades must consider application availability. Reprovisioning a DPU or restarting a critical infrastructure service can interrupt host workload networking or storage connectivity. Maintenance procedures must account for these dependencies.

09 / Packet Journey

Following a Packet Through a DPU-Enabled Kubernetes Node

Consider an application pod communicating with a remote service through an SR-IOV-backed network interface. The following sequence illustrates an eligible hardware-offloaded forwarding path.

HOST BLUEFIELD HARDWARE FABRIC APPLICATION VF CLASSIFY POLICY FORWARD UPLINK Generate Transmit Match flow Permit Select egress Deliver
Figure 8.7 — Eligible workload traffic follows an accelerated forwarding path after the necessary interfaces, policy and hardware flow rules have been established.
STEP PROCESSING STAGE ENGINEERING ACTION
01 Application transmission The application generates traffic using its configured network interface.
02 Virtual Function The hardware-backed interface submits traffic to the device.
03 Packet classification The embedded switch identifies the ingress context and relevant packet fields.
04 Policy evaluation Installed hardware rules determine the supported forwarding action.
05 Forwarding decision The device selects the appropriate egress path and performs supported modifications.
06 Physical transmission The packet enters the external network fabric through the selected uplink.
10 / Operational Evidence

Observability and Kubernetes DPU Troubleshooting

A DPU-enabled Kubernetes environment introduces multiple operational layers. Troubleshooting requires engineers to distinguish Kubernetes resource reconciliation, DPU provisioning, infrastructure service health, interface configuration and actual hardware forwarding.

A healthy application pod does not necessarily imply a healthy infrastructure data plane. Similarly, a successfully deployed infrastructure service does not prove that the intended forwarding rules have been installed in hardware.

Kubernetes Infrastructure — Read-Only Investigation
# Discover installed DPU-related API resources
kubectl api-resources | grep -Ei 'dpu|bfb'

# Inspect registered nodes and workload placement
kubectl get nodes -o wide
kubectl get pods -A -o wide

# Inspect recent Kubernetes events
kubectl get events -A --sort-by=.metadata.creationTimestamp

# Discover installed custom resource definitions
kubectl get crd | grep -Ei 'dpu|bfb'

# Inspect a discovered infrastructure resource
kubectl describe <resource-kind> <resource-name> -n <namespace>

# Inspect infrastructure service logs
kubectl logs -n <namespace> <service-pod>

# Inspect interfaces on the appropriate host or DPU
ip -d link show
devlink dev show
devlink port show

# Inspect supported OVS and hardware offload state
ovs-vsctl show
ovs-appctl dpctl/dump-flows type=offloaded

# Inspect interface traffic counters
ethtool -S <interface>
Commands are illustrative, read-only diagnostic examples. Use the appropriate Kubernetes context, node, DPU environment and privileges. Resource names and offload diagnostics depend on the installed DPF, OVS, driver and firmware versions.
OBSERVED SYMPTOM POTENTIAL FAILURE DOMAIN EVIDENCE TO INVESTIGATE
DPU not ready Provisioning or configuration DPU conditions, image status, management connectivity and controller logs.
Infrastructure pod pending Scheduling or resource allocation Node selectors, taints, resource availability and scheduler events.
Infrastructure service restarting Service configuration or runtime failure Container logs, dependencies, readiness and restart history.
Application pod cannot obtain VF Device allocation or network attachment Advertised device resources, attachment definitions and CNI events.
Pod running but unreachable Data plane or security policy Interface state, VLANs, tunnel configuration, flow rules and packet counters.
Unexpected CPU utilisation Software fallback or exception processing Offloaded flow state, unsupported actions and software datapath statistics.
Cross-tenant traffic permitted Isolation or policy mapping failure Tenant identity mapping, effective rules and all alternative forwarding paths.
Desired configuration not applied Controller reconciliation Resource conditions, observed generation where available, dependencies and controller logs.
11 / Production Design Considerations

Designing Reliable DPU-Enabled Kubernetes Platforms

DESIGN PRINCIPLE 01

Version Compatibility

Validate compatibility between BlueField hardware, firmware, DPU software, DPF, Kubernetes, drivers and infrastructure service releases.

DESIGN PRINCIPLE 02

Failure Domain Separation

Identify which host workloads depend on each DPU, infrastructure service, physical uplink and management component.

DESIGN PRINCIPLE 03

Hardware Capacity

Evaluate available hardware flow entries, interfaces, queue resources, bandwidth and supported acceleration features.

DESIGN PRINCIPLE 04

Policy Consistency

Ensure software policy intent and effective hardware enforcement remain consistent across tenant networks and alternate forwarding paths.

DESIGN PRINCIPLE 05

Controlled Upgrades

Coordinate workload maintenance, DPU provisioning, infrastructure service upgrades and validated recovery procedures.

DESIGN PRINCIPLE 06

End-to-End Observability

Correlate Kubernetes events, DPU health, service logs, interface statistics and hardware forwarding counters.

Engineering Summary

Kubernetes as the Infrastructure Orchestration Layer

BlueField introduces a dedicated infrastructure execution domain into cloud-native environments. The DPU Platform Framework extends Kubernetes-oriented lifecycle management to DPU provisioning and infrastructure service deployment.

DPUService resources provide a declarative service abstraction, while CNI integration, hardware-backed interfaces, embedded switching and supported acceleration mechanisms establish workload connectivity.

The architectural opportunity is not simply to move networking software from one processor to another. It is to separate application execution, infrastructure control and accelerated data-plane processing into independently managed but coordinated domains.

Declarative infrastructure. Independent execution domains. Hardware-accelerated forwarding. Evidence-driven operations.

NETWORK INSIGHT — ENGINEERING KNOWLEDGE SERIES BLUEFIELD DPU / SECTION 08
Network Insight / Interactive Engineering 08

Inside the DPU-Accelerated Kubernetes Cluster

Deploy infrastructure services onto BlueField DPUs, investigate Kubernetes resource allocation, attach application pods to accelerated network interfaces and troubleshoot the boundary between host workloads and programmable infrastructure.

KUBERNETES BLUEFIELD DPU DOCA PLATFORM FRAMEWORK SR-IOV MULTUS CONCEPTS INFRASTRUCTURE ISOLATION
01 / Cloud-native deployment scenarios

Select your infrastructure architecture

02 / Deployment control centre

Configure desired infrastructure state

Desired configuration is ready for reconciliation.
03 / Kubernetes infrastructure digital model

Cluster architecture

MANAGEMENT AND ORCHESTRATION PLANE KUBERNETES API Desired infrastructure state DPF MANAGEMENT Provisioning and service orchestration DATA CENTRE NETWORK FABRIC Conceptual DPF-managed infrastructure / three worker nodes
Reconcile a deployment to observe the Kubernetes infrastructure lifecycle.
Ready DPUs
0/3

Provisioned devices

Running pods
0

Allocated network resources

Pending pods
0

Unfulfilled workload demand

Allocated VFs
0

Cluster resource allocation

04 / Infrastructure reconciliation engine

From desired state to observed state

Desired state

Kubernetes resources describe the requested infrastructure configuration. Management components attempt to reconcile that configuration with the deployed environment.

Observed state

A submitted configuration does not guarantee a successful deployment. Provisioning, service readiness, resource advertisement and workload attachment must be verified.

Changes remain desired state until the reconciliation engine processes them.
05 / Observed infrastructure inventory

Inspect DPU services and workload resources

WORKER DPU NETWORK SECURITY VFs TENANT A TENANT B PENDING

Virtual function resource allocation

This model assigns one virtual function to each running accelerated pod. It uses fixed per-worker placement and does not reproduce the full Kubernetes scheduler or device-plugin allocation logic.

06 / Declarative infrastructure specification

Inspect the desired deployment document



    
This is an educational pseudo-manifest. Its fields describe the simulator's desired state and are not a deployable NVIDIA DPF API resource. Actual DPF resource schemas vary by release.
07 / Kubernetes evidence console

Inspect infrastructure diagnostics

All command output is synthetic. No connection to an actual Kubernetes cluster is made.

08 / Multi-tenant infrastructure verification

Test workload communication and isolation

Select a traffic test after deploying the required workloads.

These tests represent simplified infrastructure policy decisions. Kubernetes NetworkPolicy enforcement on secondary SR-IOV interfaces depends on the deployed networking and security implementation.

09 / Infrastructure fault injection

Introduce a Kubernetes DPU deployment failure

No fault injected.
10 / Production infrastructure incident

Incident 008 — The missing accelerated network

A multi-tenant Kubernetes cluster has undergone an infrastructure upgrade. Worker 02 is experiencing accelerated workload failures, insufficient network resources and incorrect tenant isolation configuration.

Investigate the desired and observed states. Restore Worker 02, deploy three pods for Tenant A and three pods for Tenant B, and verify that permitted traffic succeeds while cross-tenant communication is blocked.

○ Worker 02 DPU provisioned successfully.
○ Networking and security services ready.
○ At least six VFs advertised.
○ Three running pods per tenant and no pending pods.
○ Same-tenant communication verified.
○ Cross-tenant isolation verified.
Load the incident to begin your investigation.
11 / Cloud-native engineering interpretation

Understanding the DPU infrastructure boundary

DOCA Platform Framework

DPF provides Kubernetes-oriented mechanisms for provisioning DPUs and orchestrating infrastructure services. It helps manage the lifecycle of programmable infrastructure independently from ordinary application pods.

DPU infrastructure services

Selected networking, security and other infrastructure services can execute within the DPU processing domain, depending on the platform, service implementation and deployment configuration.

SR-IOV device allocation

SR-IOV exposes virtual functions that can be assigned to workloads. Kubernetes device plugins advertise suitable resources and participate in device allocation. Available resources must satisfy workload requests.

Secondary network attachment

Multus can coordinate additional pod network interfaces using delegated CNI plugins. A NetworkAttachmentDefinition can describe an additional network, while the relevant device and CNI components establish the actual attachment.

Tenant isolation

Infrastructure isolation requires explicit enforcement mechanisms. Separate namespaces, virtual functions or network attachments do not automatically guarantee complete tenant security.

Evidence-driven troubleshooting

Investigate controller availability, DPU provisioning status, service readiness, advertised resources, pod scheduling events, network attachment and actual forwarding behaviour as separate evidence domains.

View simulation scope and assumptions

The management plane combines several real-world orchestration functions into one conceptual visual domain. It is not an exact DPF deployment topology or release-specific architecture.

Each worker contains one conceptual BlueField DPU. Workload placement is fixed to the configured worker rather than dynamically scheduled.

Each accelerated pod requests one VF. Tenant A is allocated resources before Tenant B for deterministic educational behaviour. Real Kubernetes scheduling does not inherently prioritise tenants in this manner.

Missing VF resources produce Pending workloads. Allocated workloads with failed secondary attachments are represented as ContainerCreating.

Reconciliation rebuilds the selected worker's observed state. Real infrastructure controllers may preserve existing resources, retry individual operations or use more complex lifecycle transitions.

The policy model permits same-tenant and external communication when endpoints are available. Cross-tenant communication is blocked only when the modelled security service and isolation policy are active at the source.

This is an educational state machine, not a Kubernetes emulator or actual DPF controller.

NETWORK INSIGHT
Engineering Guide 06 / Cloud-Native Silicon Infrastructure
Network Insight / Interactive Engineering 09

BlueField Production Incident Simulator

Enter the silicon operations command centre. Investigate degraded infrastructure performance, correlate hardware and software evidence, identify the underlying failure and restore the accelerated data plane.

BLUEFIELD-3 CONCEPTS HARDWARE TELEMETRY DOCA SERVICES INCIDENT RESPONSE ROOT CAUSE ANALYSIS CAPSTONE LAB
01 / Production incident library

Select an infrastructure incident

Healthy infrastructure baseline loaded. Select an incident to begin.
02 / Operations control centre

Infrastructure status

BASELINE HEALTHY
Diagnostic evidence collected: 0 sources.
Collect evidence before submitting a diagnosis.
03 / Accelerated server digital model

Infrastructure processing domains

ACCELERATED INFRASTRUCTURE SERVER HOST COMPUTE DOMAIN HOST CPU APPLICATION WORKLOADS Compute / storage / networking HOST MEMORY PCIe BLUEFIELD DPU DOMAIN ARM PROCESSING / DOCA SERVICES FLOW STEERING Match / action / counters HARDWARE ACTIVE SECURITY ENGINE Infrastructure policy POLICY ACTIVE FLOW RESOURCES Entries / allocation RDMA / DATA PATH Accelerated movement DATA CENTRE NETWORK FABRIC Conceptual architecture — not an exact silicon floorplan
Healthy accelerated infrastructure path.
04 / Network state comparison engine

Baseline versus incident versus current state

TELEMETRY BASELINE INCIDENT CURRENT CONDITION
The baseline is a synthetic reference workload, not a published NVIDIA benchmark. Comparisons use the same modelled workload demand.
05 / Performance telemetry

Throughput and latency history

Throughput / left axis / Gbit/s Latency / right axis / µs

Telemetry samples are generated when the infrastructure state changes or when you select Sample telemetry. No live hardware monitoring is performed.

06 / Diagnostic evidence console

Hardware and software investigation

The NI-LAB commands are simulator commands. They are not real DOCA, Linux or firmware command-line utilities.

07 / Hardware forwarding evidence

Inspect the accelerated flow table

FLOW MATCH ACTION INSTALLATION HITS
Generate test traffic to observe forwarding and policy counter changes.
08 / Corrective action centre

Apply a targeted remediation

Select the corrective action that addresses the evidence-supported root cause. Unrelated changes will not resolve the incident.

No remediation applied.

Corrective actions represent abstract laboratory state changes. Real production changes require platform-specific procedures, impact assessment and change control.

09 / Incident investigation timeline

Operational event history

10 / BlueField engineering capstone

Evidence-driven production recovery

Complete the investigation without relying solely on performance symptoms. Collect diagnostic evidence, validate the underlying failure, restore the infrastructure and demonstrate that the recovery is operational.

○ Production incident loaded.
○ At least three independent evidence sources collected.
○ Root-cause-specific diagnostic evidence collected.
○ Correct root cause validated.
○ Appropriate corrective action applied.
○ Post-recovery traffic and security tests completed.
○ Baseline recovery verified.
Select an incident to begin the capstone.
Incident library completion: 0 / 6
11 / Engineering investigation report

Generate your incident recovery record

Complete an investigation to generate a structured incident recovery report.

12 / Production engineering interpretation

Understanding infrastructure failure domains

Hardware offload verification

A successfully configured application does not necessarily mean its traffic is processed in hardware. Inspect installation status, supported actions, hardware hits and software fallback.

PCIe performance

Negotiated PCIe generation and link width can constrain host-device data movement. Compare the observed link state with the expected platform configuration and workload requirements.

Infrastructure service health

Physical link availability does not prove that infrastructure services are functioning. Investigate service readiness, dependencies, logs and actual forwarding behaviour.

Fabric congestion

RDMA performance depends on the wider network environment. Queue occupancy, ECN marking, congestion feedback and pause behaviour can help explain degraded data movement.

Security policy correctness

A packet drop may indicate intended security enforcement or an incorrect policy. Compare the observed decision with the approved communication requirements before changing rules.

Resource exhaustion

Hardware tables and acceleration resources are finite. Resource exhaustion can prevent new flow installation even while existing hardware flows continue forwarding.

View simulation assumptions and limitations

This simulator uses six deterministic single-root-cause incident models. Real incidents may involve multiple interacting failures.

All throughput, latency, CPU utilisation, queue occupancy and hardware resource figures are illustrative. They do not represent measured BlueField performance.

Hardware resource capacity is expressed using fictional normalised entry units. Actual flow capacity depends on hardware, firmware, match fields, actions and resource allocation.

The model assumes a PCIe Gen5 x16 baseline. Actual negotiated link configuration depends on the deployed platform.

The congestion incident represents an Ethernet/RoCE environment. ECN and PFC observations are contextual evidence, not independent proof of a root cause.

The recovery engine returns the affected modelled metrics to the synthetic baseline after the correct action. Real recovery must be measured and may be incomplete.

No real firmware, hardware, security policy or production infrastructure is modified.